Assessment of effective doses for fluoroscopy-guided balloon dilatation of benign esophageal strictures in pediatric medicine
Open Access
- 20 December 2023
- journal article
- research article
- Published by SPRI of Radiation Hygiene Prof. PV Ramzaev in Radiatsionnaya Gygiena = Radiation Hygiene
- Vol. 16 (4) , 32-43
Abstract
Interventional examinations are associated with high levels of patient exposure per examination, which makes it particularly important to monitor individual patient doses and to assess radiation risks. The aim of this study was the assessment of effective doses for fluoroscopy-guided balloon dilatation of benign esophageal strictures, whichwasperformedonpediatricpatientsaged 1 to 2 yearsatthe Departmentof Radiosurgical Methodsof Diagnosis and Treatment of St. Petersburg State Pediatric Medical University. Patient exposure patterns were basedonourowndatacollection. Thecalculationofeffectiveandorgandosesofpatientsnormalizedbythevalue of the dose area product measured during the study was carried out using PCXMC 2.0 software. The conversion coefficients from the dose area product to the effective dose were calculated using tissue weighting coefficients from the ICRP Publications 60 and 103 their values were 10.7 and 11.7 µSv/cGy cm2, respectively. The results of verification of the method indicated that the use of inappropriate conversion coefficients leads to an almost double underestimation of children’s effective doses. Differences in the values of conversion coefficients are significant and are explained by differences in voltage, source to image distance, and irradiation field size. A simplified model of patient exposure was proposed, which is described by a single irradiation field. The assessment of effective doses using multi-field and single-field irradiation model shows comparable results, which allows using the differentiated approach to the assessment of radiation doses of patients.Keywords
This publication has 18 references indexed in Scilit:
- Fluoroscopy-guided balloon dilation in patients with Eustachian tube dysfunctionEuropean Radiology, 2017
- Organ and effective doses from paediatric interventional cardiology procedures in ChilePhysica Medica, 2017
- Direct Effective Dose Calculations in Pediatric Fluoroscopy-Guided Abdominal Interventions with Rando-Alderson Phantoms – Optimization of Preset Parameter SettingsPLOS ONE, 2016
- A framework for organ dose estimation in x-ray angiography and interventional radiology based on dose-related data in DICOM structured reportsPhysics in Medicine & Biology, 2016
- Effective Doses in Children: Association With Common Complex Imaging Techniques Used During Interventional Radiology ProceduresAmerican Journal of Roentgenology, 2014
- Cumulative Radiation Exposure in Pediatric Patients with Congenital Heart DiseasePediatric Cardiology, 2014
- Local Reference Levels and Organ Doses From Pediatric Cardiac Interventional ProceduresPediatric Cardiology, 2014
- Neurointerventions in Children: Radiation Exposure and Its ImportAmerican Journal of Neuroradiology, 2013
- Fluoroscopically Guided Balloon Dilation of Benign Esophageal Strictures: Incidence of Esophageal Rupture and Its Management in 589 PatientsAmerican Journal of Roentgenology, 2011
- Radiological Protection in Fluoroscopically Guided Procedures Performed Outside the Imaging DepartmentAnnals of the ICRP, 2010