ATCA Fast Data Acquisition and Processing System for JET Gamma-Ray Cameras Upgrade Diagnostic
Authors:
- Rita Costa PereiraRPRita Costa Pereira
- Ana Maria FernandesAFAna Maria Fernandes
- André C. NetoANAndré C. Neto
- Jorge SousaJSJorge Sousa
- Antonio J. BatistaABAntonio J. Batista
- Bernardo B. CarvalhoBCBernardo B. Carvalho
- Carlos M. B. A. CorreiaCCCarlos M. B. A. Correia
- Carlos A. F. VarandasCVCarlos A. F. Varandas
- 12 April 2010
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 57 (2) , 683-687
Abstract
Nuclear reaction gamma-ray diagnosis is one of the important techniques used for studying confined fast-ions. The Joint European Torus (JET) gamma-ray camera diagnostic provides information on the spatial distribution of fast ions. The system is currently being upgraded and should allow gamma-ray image measurements in high power deuterium JET pulses, and eventually in deuterium-tritium discharges. In order to fully exploit the diagnostic capabilities it is mandatory to develop a reliable, maintainable, multi-channel spectroscopy data acquisition and real-time processing (DAQP) system, which shares much of the common development for other specific implementation like Gamma-ray spectroscopy. The DAQP system is based on the Advanced Telecommunications Computing Architecture (ATCA) and contains a 6 GFLOPS x86-based control unit and three transient recorder and processing (TRP) modules, to cope with the two arrays of collimators (10 horizontal + 9 vertical lines of sight), interconnected through PCI Express (PCIe) links. Each TRP module features 8 channels of 13 bit resolution sampling at 250 MHz, 4 GByte of local memory and two field programmable gate arrays able to perform complex trigger managing modes and allowing real time analyses (pulse height analyzer and pile-up discrimination), minimizing data storage and transfer issues. The DAQP system aims at overcoming the problem of storing large amount of data during long discharges. A raw/processed mode is being developed where the acquired raw data follows two parallel paths: besides being directly stored in the on-board memory, it is processed and streamed in real-time through PCIe links. This procedure is expected to greatly reduce the amount of data and to give the possibility of allowing continuous operation of the diagnostic. During commissioning and when data validation is required, the 4 GB raw data will be executed on the x86 control unit through a well known algorithm and the result cross checked with the processed data.Keywords
This publication has 8 references indexed in Scilit:
- The control and data acquisition software for the gamma-ray spectroscopy ATCA sub-systems of the JET-EP2 enhancementsFusion Engineering and Design, 2008
- ATCA data acquisition system for gamma-ray spectrometryFusion Engineering and Design, 2008
- Fast ion JET diagnostics: confinement and lossesAIP Conference Proceedings, 2008
- ATCA digital controller hardware for vertical stabilization of plasmas in tokamaksReview of Scientific Instruments, 2006
- Gamma ray diagnostics of high temperature magnetically confined fusion plasmasPlasma Physics and Controlled Fusion, 2006
- A PCI transient recorder module for the JET magnetic proton recoil neutron spectrometerFusion Engineering and Design, 2004
- $\gamma$-ray diagnostics of energetic ions in JETNuclear Fusion, 2002
- Digital techniques for real-time pulse shaping in radiation measurementsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994