Variable Resolution Sampling and Deep Learning Image Recovery for Accelerated Multi-Spectral MRI Near Metal Implants
Preprint
Abstract
Purpose: This study presents a variable resolution (VR) sampling and deep learning reconstruction approach for multi-spectral MRI near metal implants, aiming to reduce scan times while maintaining image quality. Background: The rising use of metal implants has increased MRI scans affected by metal artifacts. Multi-spectral imaging (MSI) reduces these artifacts but sacrifices acquisition efficiency. Methods: This retrospective study on 1.5T MSI knee and hip data from patients with metal hardware used a novel spectral undersampling scheme to improve acquisition efficiency by ~40%. U-Net-based deep learning models were trained for reconstruction. Image quality was evaluated using SSIM, PSNR, and RESI metrics. Results: Deep learning reconstructions of undersampled VR data (DL-VR) showed significantly higher SSIM and PSNR values (p<0.001) compared to conventional reconstruction (CR-VR), with improved edge sharpness. Edge sharpness in DL-reconstructed images matched fully sampled references (p=0.5). Conclusion: This approach can potentially enhance MRI examinations near metal implants by reducing scan times or enabling higher resolution. Further prospective studies are needed to assess clinical value.Keywords
All Related Versions
This publication has 16 references indexed in Scilit:
- Perceptual contrast and residual self-attention generative adversarial network-based for highly under-sampled MRI reconstructionDigital Signal Processing, 2023
- Projections and Epidemiology of Revision Hip and Knee Arthroplasty in the United States to 2040-2060Arthroplasty Today, 2023
- Super-Resolution PET Imaging Using Convolutional Neural NetworksIEEE Transactions on Computational Imaging, 2020
- Safety of Magnetic Resonance Imaging in Patients with Cardiac DevicesNew England Journal of Medicine, 2017
- ACR guidance document on MR safe practices: 2013Journal of Magnetic Resonance Imaging, 2013
- Clinical safety of magnetic resonance imaging in patients with implanted SynchroMed EL infusion pumpsNeuroradiology, 2010
- SEMAC: Slice encoding for metal artifact correction in MRIMagnetic Resonance in Medicine, 2009
- A multispectral three‐dimensional acquisition technique for imaging near metal implantsMagnetic Resonance in Medicine, 2009
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Handbook of MRI Pulse Sequences2004