Determination of Inorganic Anions in Seawater Samples by Ion Chromatography with Ultraviolet Detection Using Monolithic Octadecylsilyl Columns Coated with Dodecylammonium Cation
Authors:
Open Access
- 10 October 2016
- journal article
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (10) , 1123-1128
Abstract
A fast and sensitive ion chromatographic method for the simultaneous determinations of six inorganic anions [iodate (IO3(-)), bromate (BrO3(-)), bromide (Br(-)), nitrite (NO2(-)), nitrate (NO3(-)), and iodide (I(-))] in seawater is described using dodecylammonium (DA(+))-coated monolithic octadecylsilyl (ODS) columns, a concentrated aqueous NaCl mobile phase containing dodecylammonium chloride (DAC), and a UV detector. The DA(+)-coated monolithic ODS columns show greater retention for iodate and weaker retention for iodide, compared to dilauryldimethylammonium (DDA(+))-coated monolithic ODS columns. Six anions were determined within 12 min with baseline separation without interferences by matrix ions, such as Cl(-) and SO4(2-), in seawater, compared to a DA(+)-coated particulate ODS column (it took 25 min per sample) obtained previously. The detection limits (DLs) were comparable to the DA(+)-coated particulate ODS column: IO3(-) (7.7 μg L(-1)), BrO3(-) (20), Br(-) (88), NO2(-) (0.9), NO3(-) (1.9), and I(-) (0.9) with a 100-μL sample injection. A larger sample volume injection lowered the DLs of IO3(-), BrO3(-), and I(-). The good performance was maintained for ca. 2 years examined. The robust IC system developed in the present work was successfully applied to real seawater samples without sample dilution in the recovery rates of 93 - 104% for all ions.Keywords
This publication has 26 references indexed in Scilit:
- Determination of low-level anions in seawater by ion chromatography with cycling-column-switchingJournal of Chromatography A, 2012
- Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluentAnalytical and Bioanalytical Chemistry, 2012
- Determination of bromate in sea water using multi-dimensional matrix-elimination ion chromatographyJournal of Chromatography A, 2011
- Determination of trace inorganic anions in seawater samples by ion chromatography using silica columns modified with cetyltrimethylammonium ionAnalytical and Bioanalytical Chemistry, 2008
- Onboard Determination of Submicromolar Nitrate in Seawater by Anion-Exchange Chromatography with Lithium Chloride EluentAnalytical Sciences, 2006
- Rapid determination of bromide in seawater samples by capillary ion chromatography using monolithic silica columns modified with cetyltrimethylammonium ionTalanta, 2006
- Ion chromatography for determination of nitrite and nitrate in seawater using monolithic ODS columnsJournal of Chromatography A, 2005
- Direct Determination of Bromide, Nitrate, and Iodide in Saline Matrixes Using Electrostatic Ion Chromatography with an Electrolyte as EluentAnalytical Chemistry, 1999
- Determination of total nitrogen in seawater by ion chromatography using a high-capacity anion exchange column and a UV-detector.BUNSEKI KAGAKU, 1996
- Anion chromatography using octadecylsilane reversed-phase columns coated with cetyltrimethylammonium and its application to nitrite and nitrate in seawaterAnalytical Chemistry, 1991