Determination of Inorganic Anions in Seawater Samples by Ion Chromatography with Ultraviolet Detection Using Monolithic Octadecylsilyl Columns Coated with Dodecylammonium Cation

Authors:

Abstract
A fast and sensitive ion chromatographic method for the simultaneous determinations of six inorganic anions [iodate (IO3(-)), bromate (BrO3(-)), bromide (Br(-)), nitrite (NO2(-)), nitrate (NO3(-)), and iodide (I(-))] in seawater is described using dodecylammonium (DA(+))-coated monolithic octadecylsilyl (ODS) columns, a concentrated aqueous NaCl mobile phase containing dodecylammonium chloride (DAC), and a UV detector. The DA(+)-coated monolithic ODS columns show greater retention for iodate and weaker retention for iodide, compared to dilauryldimethylammonium (DDA(+))-coated monolithic ODS columns. Six anions were determined within 12 min with baseline separation without interferences by matrix ions, such as Cl(-) and SO4(2-), in seawater, compared to a DA(+)-coated particulate ODS column (it took 25 min per sample) obtained previously. The detection limits (DLs) were comparable to the DA(+)-coated particulate ODS column: IO3(-) (7.7 μg L(-1)), BrO3(-) (20), Br(-) (88), NO2(-) (0.9), NO3(-) (1.9), and I(-) (0.9) with a 100-μL sample injection. A larger sample volume injection lowered the DLs of IO3(-), BrO3(-), and I(-). The good performance was maintained for ca. 2 years examined. The robust IC system developed in the present work was successfully applied to real seawater samples without sample dilution in the recovery rates of 93 - 104% for all ions.

This publication has 26 references indexed in Scilit: