Kazuaki Ito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kazuaki Ito has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Takeshi Hirokawa
Emeritus Professor, Hiroshima University
8 shared publicationsHiroshi Sunahara
3 shared publicationsKengo Yamane
Kindai University
3 shared publicationsYohichi Takayama
3 shared publicationsYuuta Horioka
Kindai University
3 shared publications- Kazuhiko Tanaka
Graduate School for International Development and Cooperation, Hiroshima University, Hiroshima 739-8529, Japan
2 shared publications
Latest Publications
- 8 March 2018
- Published by Springer Nature in Aquatic Geochemistry
- Vol. 24 (2) , 163-164
Correction to: The Iodide and Iodate Distribution in the Seto Inland Sea, Japan
- 8 March 2018
- Published by Springer Nature in Aquatic Geochemistry
- Vol. 24 (2) , 163-164
Correction to: The Iodide and Iodate Distribution in the Seto Inland Sea, Japan
- 1 January 2018
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 67 (1) , 51-59
Determination of Inorganic Anions in Seawater Samples by Ion Chromatography - Effects of Residual Silanol Groups on a Reversed-phase C18 Silica Column -
イオンクロマトグラフィー(IC)による,海水中に存在する6種無機陰イオン[ヨウ素酸イオン(IO3−),臭素酸イオン(BrO3−),臭化物イオン(Br−),亜硝酸イオン(NO2−),硝酸イオン(NO3−),ヨウ化物イオン(I−)]の一斉定量を検討した.分離カラムとして残存シラノール基を持つ逆相系C18シリカカラムを用いた.溶離液に0.3 M塩化ナトリウム+0.5 mM塩化ドデシルアンモニウム(DAC)+5 mMリン酸緩衝液(pH 4.5)(流量1 mL min−1),検出器にUV検出器(225 nm)を用いたところ,19分以内で目的イオンの測定が可能であった.残存シラノール基を持つ逆相系C18シリカカラム(エンドキャップ未処理カラム)はエンドキャップ処理カラムと比べてBr−とNO2−間の分離が良好であった.繰り返し精度は保持時間,ピーク面積,ピーク高さの相対標準偏差(RSD(%))が1.55% 以内(n=5)であり,24時間の連続測定では2.97% 以内(n=48)であった.検量線は良好な直線性(r2>0.999)を示した.検出限界値(S/N=3)は,IO3−(8.3 μg L−1),BrO3−(24 μg L−1),Br−(92 μg L−1),NO2−(0.8 μg L−1),NO3−(3.2 μg L−1),I−(1.0 μg L−1)であった.瀬戸内海水の標準添加による回収率は93~108% であった.本法を瀬戸内海(広島湾)5地点で夏季の海水中陰イオン濃度の深度依存性に適用した.溶離液の流量1.5 mL min−1では対象イオンの分離・検出に問題はなく1サンプルの測定時間は13分であった.
- 1 January 2018
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 67 (1) , 51-59
Determination of Inorganic Anions in Seawater Samples by Ion Chromatography - Effects of Residual Silanol Groups on a Reversed-phase C18 Silica Column -
イオンクロマトグラフィー(IC)による,海水中に存在する6種無機陰イオン[ヨウ素酸イオン(IO3−),臭素酸イオン(BrO3−),臭化物イオン(Br−),亜硝酸イオン(NO2−),硝酸イオン(NO3−),ヨウ化物イオン(I−)]の一斉定量を検討した.分離カラムとして残存シラノール基を持つ逆相系C18シリカカラムを用いた.溶離液に0.3 M塩化ナトリウム+0.5 mM塩化ドデシルアンモニウム(DAC)+5 mMリン酸緩衝液(pH 4.5)(流量1 mL min−1),検出器にUV検出器(225 nm)を用いたところ,19分以内で目的イオンの測定が可能であった.残存シラノール基を持つ逆相系C18シリカカラム(エンドキャップ未処理カラム)はエンドキャップ処理カラムと比べてBr−とNO2−間の分離が良好であった.繰り返し精度は保持時間,ピーク面積,ピーク高さの相対標準偏差(RSD(%))が1.55% 以内(n=5)であり,24時間の連続測定では2.97% 以内(n=48)であった.検量線は良好な直線性(r2>0.999)を示した.検出限界値(S/N=3)は,IO3−(8.3 μg L−1),BrO3−(24 μg L−1),Br−(92 μg L−1),NO2−(0.8 μg L−1),NO3−(3.2 μg L−1),I−(1.0 μg L−1)であった.瀬戸内海水の標準添加による回収率は93~108% であった.本法を瀬戸内海(広島湾)5地点で夏季の海水中陰イオン濃度の深度依存性に適用した.溶離液の流量1.5 mL min−1では対象イオンの分離・検出に問題はなく1サンプルの測定時間は13分であった.
- Open Access
- 10 October 2016
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (10) , 1123-1128
Determination of Inorganic Anions in Seawater Samples by Ion Chromatography with Ultraviolet Detection Using Monolithic Octadecylsilyl Columns Coated with Dodecylammonium Cation
A fast and sensitive ion chromatographic method for the simultaneous determinations of six inorganic anions [iodate (IO3(-)), bromate (BrO3(-)), bromide (Br(-)), nitrite (NO2(-)), nitrate (NO3(-)), and iodide (I(-))] in seawater is described using dodecylammonium (DA(+))-coated monolithic octadecylsilyl (ODS) columns, a concentrated aqueous NaCl mobile phase containing dodecylammonium chloride (DAC), and a UV detector. The DA(+)-coated monolithic ODS columns show greater retention for iodate and weaker retention for iodide, compared to dilauryldimethylammonium (DDA(+))-coated monolithic ODS columns. Six anions were determined within 12 min with baseline separation without interferences by matrix ions, such as Cl(-) and SO4(2-), in seawater, compared to a DA(+)-coated particulate ODS column (it took 25 min per sample) obtained previously. The detection limits (DLs) were comparable to the DA(+)-coated particulate ODS column: IO3(-) (7.7 μg L(-1)), BrO3(-) (20), Br(-) (88), NO2(-) (0.9), NO3(-) (1.9), and I(-) (0.9) with a 100-μL sample injection. A larger sample volume injection lowered the DLs of IO3(-), BrO3(-), and I(-). The good performance was maintained for ca. 2 years examined. The robust IC system developed in the present work was successfully applied to real seawater samples without sample dilution in the recovery rates of 93 - 104% for all ions.
- 10 October 2016
- Published by Springer Nature in Analytical Sciences
- Vol. 32 (10) , 1123-1128
Open AccessDetermination of Inorganic Anions in Seawater Samples by Ion Chromatography with Ultraviolet Detection Using Monolithic Octadecylsilyl Columns Coated with Dodecylammonium Cation
A fast and sensitive ion chromatographic method for the simultaneous determinations of six inorganic anions [iodate (IO3(-)), bromate (BrO3(-)), bromide (Br(-)), nitrite (NO2(-)), nitrate (NO3(-)), and iodide (I(-))] in seawater is described using dodecylammonium (DA(+))-coated monolithic octadecylsilyl (ODS) columns, a concentrated aqueous NaCl mobile phase containing dodecylammonium chloride (DAC), and a UV detector. The DA(+)-coated monolithic ODS columns show greater retention for iodate and weaker retention for iodide, compared to dilauryldimethylammonium (DDA(+))-coated monolithic ODS columns. Six anions were determined within 12 min with baseline separation without interferences by matrix ions, such as Cl(-) and SO4(2-), in seawater, compared to a DA(+)-coated particulate ODS column (it took 25 min per sample) obtained previously. The detection limits (DLs) were comparable to the DA(+)-coated particulate ODS column: IO3(-) (7.7 μg L(-1)), BrO3(-) (20), Br(-) (88), NO2(-) (0.9), NO3(-) (1.9), and I(-) (0.9) with a 100-μL sample injection. A larger sample volume injection lowered the DLs of IO3(-), BrO3(-), and I(-). The good performance was maintained for ca. 2 years examined. The robust IC system developed in the present work was successfully applied to real seawater samples without sample dilution in the recovery rates of 93 - 104% for all ions.
- 18 September 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 404 (8) , 2513-2517
Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent
A method was developed for determination of inorganic anions, including nitrite (NO 2 − ), nitrate (NO 3 − ), bromide (Br−), and iodide (I−), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50 × 4.6 mm i.d. and 100 × 4.6 mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5 mol/L; flow rate, 3 mL/min) containing 5 mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225 nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H2O/methanol, 90:10 v/v). The hydrophilic ions (NO 2 − , NO 3 − , and Br−) were separated within 3 min and the retention time of I− was 16 min. No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35 ‰ artificial seawater. The detection limits were 0.6 μg/L for NO 2 − , 1.1 μg/L for NO 3 − , 70 μg/L for Br−, and 1.6 μg/L for I− with a 200-μL sample injection. The performance of the coated columns was maintained without addition of DDAB in the eluent. The IC system was successfully applied to real seawater samples with recovery rates of 94–108 % for all ions.
- 18 September 2012
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 404 (8) , 2513-2517
Determination of nitrite, nitrate, bromide, and iodide in seawater by ion chromatography with UV detection using dilauryldimethylammonium-coated monolithic ODS columns and sodium chloride as an eluent
A method was developed for determination of inorganic anions, including nitrite (NO 2 − ), nitrate (NO 3 − ), bromide (Br−), and iodide (I−), in seawater by ion chromatography (IC). The IC system used two dilauryldimethylammonium bromide (DDAB)-coated monolithic ODS columns (50 × 4.6 mm i.d. and 100 × 4.6 mm i.d.) connected in series for separation of the ions. Aqueous NaCl (0.5 mol/L; flow rate, 3 mL/min) containing 5 mmol/L phosphate buffer (pH 5) was used as the eluent, and detection was with a UV detector at 225 nm. The monolithic ODS columns were coated and equilibrated with a 1-mmol/L DDAB solution (in H2O/methanol, 90:10 v/v). The hydrophilic ions (NO 2 − , NO 3 − , and Br−) were separated within 3 min and the retention time of I− was 16 min. No interferences from matrix ions, such as chloride and sulfate ions, were observed in 35 ‰ artificial seawater. The detection limits were 0.6 μg/L for NO 2 − , 1.1 μg/L for NO 3 − , 70 μg/L for Br−, and 1.6 μg/L for I− with a 200-μL sample injection. The performance of the coated columns was maintained without addition of DDAB in the eluent. The IC system was successfully applied to real seawater samples with recovery rates of 94–108 % for all ions.
- 1 April 2012
- Vol. 30 (4) , 369-73
[Analysis of aliphatic carboxylic acids in anaerobic digestion process waters by ion-exclusion chromatography].
The analysis of seven aliphatic carboxylic acids (formic, acetic, propionic, iso-butyric, n-butyric, iso-valeric and n-valeric acid) in anaerobic digestion process waters for biogas production was examined by ion-exclusion chromatography with dilute acidic eluents (benzoic acid, perfluorobutyric acid (PFBA) and sulfuric acid) and non-suppressed conductivity/ultraviolet (UV) detection. The columns used were a styrene/divinylbenzene-based strongly acidic cation-exchange resin column (TSKgel SCX) and a polymethacrylate-based weakly acidic cation-exchange resin column (TSKgel Super IC-A/C). Good separation was performed on the TSKgel SCX in shorter retention times. For the TSKgel Super IC-A/C, peak shape of the acids was sharp and symmetrical in spite of longer retention times. In addition, the mutual separation of the acids was good except for iso- and n-butyric acids. The better separation and good detection was achieved by using the two columns (TSKgel SCX and TSKgel Super IC-A/C connected in series), lower concentrations of PFBA and sulfuric acid as eluents, non-suppressed conductivity detection and UV detection at 210 nm. This analysis was applied to anaerobic digestion process waters. The chromatograms with conductivity detection were relatively simpler compared with those of UV detection. The use of two columns with different selectivities for the aliphatic carboxylic acids and the two detection modes was effective for the determination and identification of the analytes in anaerobic digestion process waters containing complex matrices.
- 1 April 2012
- Vol. 30 (4) , 369-73
[Analysis of aliphatic carboxylic acids in anaerobic digestion process waters by ion-exclusion chromatography].
The analysis of seven aliphatic carboxylic acids (formic, acetic, propionic, iso-butyric, n-butyric, iso-valeric and n-valeric acid) in anaerobic digestion process waters for biogas production was examined by ion-exclusion chromatography with dilute acidic eluents (benzoic acid, perfluorobutyric acid (PFBA) and sulfuric acid) and non-suppressed conductivity/ultraviolet (UV) detection. The columns used were a styrene/divinylbenzene-based strongly acidic cation-exchange resin column (TSKgel SCX) and a polymethacrylate-based weakly acidic cation-exchange resin column (TSKgel Super IC-A/C). Good separation was performed on the TSKgel SCX in shorter retention times. For the TSKgel Super IC-A/C, peak shape of the acids was sharp and symmetrical in spite of longer retention times. In addition, the mutual separation of the acids was good except for iso- and n-butyric acids. The better separation and good detection was achieved by using the two columns (TSKgel SCX and TSKgel Super IC-A/C connected in series), lower concentrations of PFBA and sulfuric acid as eluents, non-suppressed conductivity detection and UV detection at 210 nm. This analysis was applied to anaerobic digestion process waters. The chromatograms with conductivity detection were relatively simpler compared with those of UV detection. The use of two columns with different selectivities for the aliphatic carboxylic acids and the two detection modes was effective for the determination and identification of the analytes in anaerobic digestion process waters containing complex matrices.
- 21 February 2012
- Published by Taylor & Francis in Analytical Letters
- Vol. 45 (8) , 862-871
Pyrohydrolysis Coupled to Ion Chromatography for Sensitive Determination of Iodine in Food-Related Materials
For the determination of iodine in food-related materials, the biological sample was decomposed using a pyrohydrolytic procedure. A sample vessel made from mullite, in which an aliquot of sample was taken, was placed in a quartz tube, and heated at 100°C through 820°C step by step under wet oxygen flow. Iodine in the sample was separated by evaporation as hydrogen iodide and collected in a dilute sodium hydroxide solution. After the basic solution containing the analyte was neutralized by adding hydrochloric acid, iodine in the solution was determined by using ion chromatography with ultraviolet absorption detection. The operating conditions for the pyrohydrolytic decomposition procedure were examined. Under the optimized conditions, organic constituents in the sample were completely decomposed since the analyte species were converted to the iodide ion. The detection limit of 0.01 µg g−1 iodine was established with a reproducibility of 1.2% when a sample of 500 mg was taken. This method was applied to the determination of iodine in various certified reference materials and food samples with satisfactory results.
- 21 February 2012
- Published by Taylor & Francis in Analytical Letters
- Vol. 45 (8) , 862-871
Pyrohydrolysis Coupled to Ion Chromatography for Sensitive Determination of Iodine in Food-Related Materials
For the determination of iodine in food-related materials, the biological sample was decomposed using a pyrohydrolytic procedure. A sample vessel made from mullite, in which an aliquot of sample was taken, was placed in a quartz tube, and heated at 100°C through 820°C step by step under wet oxygen flow. Iodine in the sample was separated by evaporation as hydrogen iodide and collected in a dilute sodium hydroxide solution. After the basic solution containing the analyte was neutralized by adding hydrochloric acid, iodine in the solution was determined by using ion chromatography with ultraviolet absorption detection. The operating conditions for the pyrohydrolytic decomposition procedure were examined. Under the optimized conditions, organic constituents in the sample were completely decomposed since the analyte species were converted to the iodide ion. The detection limit of 0.01 µg g−1 iodine was established with a reproducibility of 1.2% when a sample of 500 mg was taken. This method was applied to the determination of iodine in various certified reference materials and food samples with satisfactory results.
- 1 January 2010
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 59 (10) , 879-884
Simultaneous Determination of Nitrite, Nitrate, and Ammonium Ions in Lake and River-Water Samples by Ion Chromatography
- 1 January 2010
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 59 (10) , 879-884
Simultaneous Determination of Nitrite, Nitrate, and Ammonium Ions in Lake and River-Water Samples by Ion Chromatography
- 1 August 2005
- Published by Elsevier in Journal of Chromatography A
- Vol. 1083 (1-2) , 63-67
Ion chromatography for determination of nitrite and nitrate in seawater using monolithic ODS columns
- 1 August 2005
- Published by Elsevier in Journal of Chromatography A
- Vol. 1083 (1-2) , 63-67
Ion chromatography for determination of nitrite and nitrate in seawater using monolithic ODS columns
- 19 May 2001
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (5) , 579-581
Enhanced Detection of Iodide in Seawater by Ion Chromatography Using an ODS Column Coated with Cetyltrimethylammonium
- 19 May 2001
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (5) , 579-581
Enhanced Detection of Iodide in Seawater by Ion Chromatography Using an ODS Column Coated with Cetyltrimethylammonium