Performance Enhancement Analysis of Environmentally Friendly Refrigerants
Open Access
Abstract
Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, −20, −40, and −60 °C and condensation temperatures of 30, 40, and 50 °C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 °C and −20 °C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = −40 °C and −60 °C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = −60 °C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = −40 °C and −60 °C. However, the growth rate of R717 ranks last for Teva = −60 °C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.Keywords
Funding Information
- Ministry of Science and Technology, Taiwan (NSTC 112-2221-E-992-051)
This publication has 25 references indexed in Scilit:
- A Comprehensive Thermodynamic Assessment of Cascade Refrigeration System Utilizing Low GWP Hydrocarbon RefrigerantsInternational Journal of Thermofluids, 2022
- Comprehensive experimental evaluation of R1234yf-based low GWP working fluids for refrigeration and heat pumpsEnergy Conversion and Management, 2022
- Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a, R1234yf, R290, R1270, R600a and R744Energy Conversion and Management, 2022
- Energy and exergy analysis of a Linde-Hampson refrigeration system using R170, R41 and R1132a as low-GWP refrigerant blend components to replace R23Energy, 2021
- Comparative study on energy efficiency of low GWP refrigerants in domestic refrigerators with capacity modulationEnergy and Buildings, 2019
- Energy and exergy analysis of low GWP refrigerants in cascade refrigeration systemEnergy, 2019
- R450A and R513A as lower GWP mixtures for high ambient temperature countries: Experimental comparison with R134aEnergy, 2019
- Hydrocarbon refrigerants HC290 (Propane) and HC1270 (Propylene) low GWP long-term substitutes for HFC404A: A comparative analysis in vaporisation inside a small-diameter horizontal smooth tubeApplied Thermal Engineering, 2017
- Experimental evaluation of R448A as R404A lower-GWP alternative in refrigeration systemsEnergy Conversion and Management, 2015
- The Role of Environmental Metrics (GWP, TEWI, LCCP) in the Selection Of Low GWP RefrigerantEnergy Procedia, 2014