Rong-Hua Yeh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rong-Hua Yeh has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Min-Hsiung Yang
Department of Mechanical and Electro-mechanical Engineering, National Sun Yat-Sen University, Taiwan, ROC
5 shared publications Min-Hsiung Yang
4 shared publicationsChin-Ko Yeh
Department of Marine Engineering, National Kaohsiung University of Science and Technology, Taiwan, R.O.C
1 shared publication- Chun-Yu Hsieh
Department of Marine Engineering, National Kaohsiung University of Science and Technology, Kaohsiung City 805301, Taiwan
1 shared publication Guan-Ming Huang
1 shared publicationHai-Ping Hu
National Taiwan Ocean University
1 shared publication
Latest Publications
- Open Access
- 25 November 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Theoretical study of the optimal intermediate pressures for a two-stage vapor-compression refrigeration system with ecofriendly refrigerants
- 25 November 2025
- Published by Elsevier in Results in Engineering
- Vol. 28
Open AccessTheoretical study of the optimal intermediate pressures for a two-stage vapor-compression refrigeration system with ecofriendly refrigerants
- 1 January 2025
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 32 (2) , 1-26
EXPERIMENTAL STUDY OF FULLY DEVELOPED TURBULENT FLOW IN INTERNALLY FINNED TUBES
A steady, hydrodynamically and thermally fully developed turbulent water flow in internally finned tubes with constant-heat-flux boundary condition is investigated experimentally. In this experiment, 70°C hot water passes the inner tube while 20°C cold water flows through the annulus passage. In order to eliminate thermal contact resistance, the circular tube having a length of 1400 mm with inner fins is directly milled from a cylinder. Apart from a smooth tube, three internal-finned-tube heat exchangers having 4, 6, and 8 longitudinal trapezoidal fins are tested. For Re = 5000, the tested tubes with 4, 6, and 8 fins can improve thermal performance by approximately 35.4, 44.6, and 67.2%, respectively, but merely increase friction factor by 1.92, 4.8, and 6.73%, respectively, compared to a smooth tube. The increases with respect to to a smooth tube in both Nu and f become smaller at a higher Re for N = 4, 6, and 8. As pressure drop, increases, the Q of the tested finned tubes first grows rapidly, and this growth curve gradually becomes flatter at a higher ΔP. Consequently, the heat-transfer performance will become worse as ΔP > 3.5 kPa for the proposed heat exchangers. Additionally, the performance evaluation criterion (PEC) is proposed to assess the performances of the proposed internally finned tubes. It is shown that the heat exchanger with 8 fins has the best thermo-hydraulic performance. Finally, correlating equations for Nu and f with respect to Re are presented for a range of 3000 ≤ Re ≤ 7250 and N = 0, 4, 6, and 8.
- 1 January 2025
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 32 (2) , 1-26
EXPERIMENTAL STUDY OF FULLY DEVELOPED TURBULENT FLOW IN INTERNALLY FINNED TUBES
A steady, hydrodynamically and thermally fully developed turbulent water flow in internally finned tubes with constant-heat-flux boundary condition is investigated experimentally. In this experiment, 70°C hot water passes the inner tube while 20°C cold water flows through the annulus passage. In order to eliminate thermal contact resistance, the circular tube having a length of 1400 mm with inner fins is directly milled from a cylinder. Apart from a smooth tube, three internal-finned-tube heat exchangers having 4, 6, and 8 longitudinal trapezoidal fins are tested. For Re = 5000, the tested tubes with 4, 6, and 8 fins can improve thermal performance by approximately 35.4, 44.6, and 67.2%, respectively, but merely increase friction factor by 1.92, 4.8, and 6.73%, respectively, compared to a smooth tube. The increases with respect to to a smooth tube in both Nu and f become smaller at a higher Re for N = 4, 6, and 8. As pressure drop, increases, the Q of the tested finned tubes first grows rapidly, and this growth curve gradually becomes flatter at a higher ΔP. Consequently, the heat-transfer performance will become worse as ΔP > 3.5 kPa for the proposed heat exchangers. Additionally, the performance evaluation criterion (PEC) is proposed to assess the performances of the proposed internally finned tubes. It is shown that the heat exchanger with 8 fins has the best thermo-hydraulic performance. Finally, correlating equations for Nu and f with respect to Re are presented for a range of 3000 ≤ Re ≤ 7250 and N = 0, 4, 6, and 8.
- Open Access
Investigation of low-GWP working fluids as substitutes for R245fa in organic Rankine cycle application
- Open Access
Performance Enhancement Analysis of Environmentally Friendly Refrigerants
Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, −20, −40, and −60 °C and condensation temperatures of 30, 40, and 50 °C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 °C and −20 °C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = −40 °C and −60 °C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = −60 °C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = −40 °C and −60 °C. However, the growth rate of R717 ranks last for Teva = −60 °C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.
Open AccessPerformance Enhancement Analysis of Environmentally Friendly Refrigerants
Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, −20, −40, and −60 °C and condensation temperatures of 30, 40, and 50 °C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 °C and −20 °C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = −40 °C and −60 °C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = −60 °C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = −40 °C and −60 °C. However, the growth rate of R717 ranks last for Teva = −60 °C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.
- Open Access
- 31 March 2023
- Published by National Taiwan Ocean University in Journal of Marine Science and Technology
- Vol. 31 (1) , 1-12
Combustion of scrap waste tires of a cogeneration plant
Various fuels can be used in circulating fluidized bed (CFB) boilers. In this study, the thermal and economic performance was investigated for three CFB fuels—heavy fuel oil, coal, and waste tire scraps—used in a cogeneration plant. The plant comprised a CFB boiler, a single-cylinder steam-extraction turbine, and a generator. Tire scrap combustion generated the most power per ton during peak hours: approximately 27.5% more than that generated using heavy oil and 42.3% more than when coal was employed; it also resulted in higher boiler efficiency during peak operation than coal (1.2% higher) or heavy oil (12.6% higher). The net plant efficiency during peak hours was highest for coal (25.09%), followed by tire scraps (23.82%) and heavy oil (18.11%). On the basis of international spot fuel prices, tire scraps were determined to have the lowest cost per kilowatt-hour generated, followed by coal and heavy oil. Using waste tire scraps as fuel can not only reduce pollution but also help hedge against international crises, which can affect energy imports.
- 31 March 2023
- Published by National Taiwan Ocean University in Journal of Marine Science and Technology
- Vol. 31 (1) , 1-12
Open AccessCombustion of scrap waste tires of a cogeneration plant
Various fuels can be used in circulating fluidized bed (CFB) boilers. In this study, the thermal and economic performance was investigated for three CFB fuels—heavy fuel oil, coal, and waste tire scraps—used in a cogeneration plant. The plant comprised a CFB boiler, a single-cylinder steam-extraction turbine, and a generator. Tire scrap combustion generated the most power per ton during peak hours: approximately 27.5% more than that generated using heavy oil and 42.3% more than when coal was employed; it also resulted in higher boiler efficiency during peak operation than coal (1.2% higher) or heavy oil (12.6% higher). The net plant efficiency during peak hours was highest for coal (25.09%), followed by tire scraps (23.82%) and heavy oil (18.11%). On the basis of international spot fuel prices, tire scraps were determined to have the lowest cost per kilowatt-hour generated, followed by coal and heavy oil. Using waste tire scraps as fuel can not only reduce pollution but also help hedge against international crises, which can affect energy imports.
- 1 January 2021
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 28 (2) , 19-40
HEAT TRANSFER ANALYSIS OF HEAT SINK MODULES FOR HIGH-POWER LED EQUIPMENT
This study presented a two-dimensional heat transfer analysis of the light-emitting-diodes equipment’s heat sink module under forced convection theoretically. The metal materials of the base and fins in the heat sink included Cu, Al, Al alloy, Mg, Zn, Fe, constantan and stainless steel. The point-matching and series truncation methods were used to solve the heat transfer problem. Due to the complexity of the system, the heat sink was divided into two regions, i.e. base and fin, and were solved individually. The temperature distribution of the heat sink module was then obtained by imposing continuity of temperature and heat flux at the interface between the two regions. The results showed that the materials of fins had little effects on heat transfer rates and the differences in mean temperatures of the heat sinks for different materials are not pronounced for a smaller Bi. In addition, when the base of the heat sink was made of aluminum, a 7.4-fold, a 5.6-fold, and a 0.7-fold increases in Q* for copper fins, iron fins, and stainless steel fins were obtained, as Bi was raised from 0.0005 to 0.005 for W=0.5, T=0.5 and L=1.
- 1 January 2021
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 28 (2) , 19-40
HEAT TRANSFER ANALYSIS OF HEAT SINK MODULES FOR HIGH-POWER LED EQUIPMENT
This study presented a two-dimensional heat transfer analysis of the light-emitting-diodes equipment’s heat sink module under forced convection theoretically. The metal materials of the base and fins in the heat sink included Cu, Al, Al alloy, Mg, Zn, Fe, constantan and stainless steel. The point-matching and series truncation methods were used to solve the heat transfer problem. Due to the complexity of the system, the heat sink was divided into two regions, i.e. base and fin, and were solved individually. The temperature distribution of the heat sink module was then obtained by imposing continuity of temperature and heat flux at the interface between the two regions. The results showed that the materials of fins had little effects on heat transfer rates and the differences in mean temperatures of the heat sinks for different materials are not pronounced for a smaller Bi. In addition, when the base of the heat sink was made of aluminum, a 7.4-fold, a 5.6-fold, and a 0.7-fold increases in Q* for copper fins, iron fins, and stainless steel fins were obtained, as Bi was raised from 0.0005 to 0.005 for W=0.5, T=0.5 and L=1.
- 29 November 2019
- Published by Wiley in International Journal of Energy Research
- Vol. 44 (2) , 1012-1030
Optimum composition ratios of multicomponent mixtures of organic Rankine cycle for engine waste heat recovery
- 29 November 2019
- Published by Wiley in International Journal of Energy Research
- Vol. 44 (2) , 1012-1030
Optimum composition ratios of multicomponent mixtures of organic Rankine cycle for engine waste heat recovery
- 1 March 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 114, 1343-1354
Economic research of the transcritical Rankine cycle systems to recover waste heat from the marine medium-speed diesel engine
- 1 March 2017
- Published by Elsevier in Applied Thermal Engineering
- Vol. 114, 1343-1354
Economic research of the transcritical Rankine cycle systems to recover waste heat from the marine medium-speed diesel engine