Accuracy of Computer Assisted Percutaneous Placement of Hiosacral Screws: A Cadaveric Study
Authors:
- S. B. AntekeierSAS. B. Antekeier
- D. P. AntekeierDAD. P. Antekeier
- C. H. CrawfordCCC. H. Crawford
- A. L. MalkaniAMA. L. Malkani
- 6 January 2003
- journal article
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 8 (4) , 198-203
Abstract
To determine the accuracy of computer-assisted fluoronavigation for percutaneous iliosacral screw placement. A fluoronavigation system (Stryker Navigation System, Stryker Leibinger, Kalamazoo, MI) was used to guide the placement of four iliosacral screws into the S-1 bodies of each of five cadaveric pelvic specimens with intact soft tissues. Accuracy of screw placement was verified by radiographs, CT scans, and direct dissection. All 20 screws were placed accurately without complications. Nineteen screws were completely contained within the osseous "safe zone." On direct dissection, one screw was noted to have penetrated the S-1 foramina by 3 mm without impingement on the nerve root. This was not detected on radiograph or CT scan. The results of this study support the safety and accuracy of computer-assisted fluoronavigation for iliosacral screw placement. The advantages include decreased fluoroscopic time, real-time simultaneous visualization of all three views (inlet, outlet, and lateral), and increased accuracy of placement. Clinical study is warranted.Keywords
This publication has 29 references indexed in Scilit:
- Computer-Assisted Fracture Reduction of Pelvic Ring Fractures: An In Vitro StudyClinical Orthopaedics and Related Research, 2002
- Radiation Exposure During Fluoroscopically Assisted Pedicle Screw Insertion in the Lumbar SpineSpine, 2000
- Radiation Dose for Pedicle Screw InsertionSpine, 1999
- Iliosacral Screw Insertion Using Computer-Assisted CT Image Guidance: a Laboratory StudyComputer Aided Surgery, 1998
- Radiation Exposure to the Orthopaedic Surgical Team During Fluoroscopy: "How Far Away Is Far Enough?"Journal of Orthopaedic Trauma, 1997
- Closed Reduction and Percutaneous Skeletal Fixation of Sacral FracturesClinical Orthopaedics and Related Research, 1996
- Proximity of Iliosacral Screws to Neurovascular Structures After Internal FixationClinical Orthopaedics and Related Research, 1996
- Radiographic Recognition of the Sacral Alar Slope for Optimal Placement of Iliosacral Screws: A Cadaveric and Clinical StudyJournal of Orthopaedic Trauma, 1996
- Posterior Sacroiliac Fixation Using a Sacral Pedicle Targeting Device: An Anatomical StudyJournal of Orthopaedic Trauma, 1993
- Sacral FracturesClinical Orthopaedics and Related Research, 1988