S. B. Antekeier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
S. B. Antekeier has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
A. L. Malkani
1 shared publicationC. H. Crawford
1 shared publicationD. P. Antekeier
1 shared publication
Latest Publications
- 6 January 2003
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 8 (4) , 198-203
Accuracy of Computer Assisted Percutaneous Placement of Hiosacral Screws: A Cadaveric Study
To determine the accuracy of computer-assisted fluoronavigation for percutaneous iliosacral screw placement. A fluoronavigation system (Stryker Navigation System, Stryker Leibinger, Kalamazoo, MI) was used to guide the placement of four iliosacral screws into the S-1 bodies of each of five cadaveric pelvic specimens with intact soft tissues. Accuracy of screw placement was verified by radiographs, CT scans, and direct dissection. All 20 screws were placed accurately without complications. Nineteen screws were completely contained within the osseous "safe zone." On direct dissection, one screw was noted to have penetrated the S-1 foramina by 3 mm without impingement on the nerve root. This was not detected on radiograph or CT scan. The results of this study support the safety and accuracy of computer-assisted fluoronavigation for iliosacral screw placement. The advantages include decreased fluoroscopic time, real-time simultaneous visualization of all three views (inlet, outlet, and lateral), and increased accuracy of placement. Clinical study is warranted.
- 6 January 2003
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 8 (4) , 198-203
Accuracy of Computer Assisted Percutaneous Placement of Hiosacral Screws: A Cadaveric Study
To determine the accuracy of computer-assisted fluoronavigation for percutaneous iliosacral screw placement. A fluoronavigation system (Stryker Navigation System, Stryker Leibinger, Kalamazoo, MI) was used to guide the placement of four iliosacral screws into the S-1 bodies of each of five cadaveric pelvic specimens with intact soft tissues. Accuracy of screw placement was verified by radiographs, CT scans, and direct dissection. All 20 screws were placed accurately without complications. Nineteen screws were completely contained within the osseous "safe zone." On direct dissection, one screw was noted to have penetrated the S-1 foramina by 3 mm without impingement on the nerve root. This was not detected on radiograph or CT scan. The results of this study support the safety and accuracy of computer-assisted fluoronavigation for iliosacral screw placement. The advantages include decreased fluoroscopic time, real-time simultaneous visualization of all three views (inlet, outlet, and lateral), and increased accuracy of placement. Clinical study is warranted.