Haptic Guidance for Robot-Assisted Endovascular Procedures: Implementation and Evaluation on Surgical Simulator
- 1 November 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5398-5403
Abstract
Vascular diseases are the most common precursors to ischemic heart disease and stroke, which are two of the leading causes of death worldwide. Endovascular intervention is a minimally invasive surgical approach to treat such diseases. Compared to open surgery, it has the advantages of faster recovery, reduced need for general anesthesia, reduced blood loss and significantly lower mortality. Endovascular procedures require high surgical skills to minimize contacts between the manipulated instruments (catheters and guidewires) and the vessel wall, which represent one of the major risks for the patient. Robotic assistance can potentially improve the precision and stability of instruments manipulation. One key limitation of current commercial robotic platforms is the lack of haptic feedback, preventing their acceptance and limiting the clinical usability. This paper proposes to bring the benefit of haptic feedback to robot-assisted endovascular intervention. Here we hypothesize that the introduction of 3D haptic guidance during robot-assisted endovascular procedure can further improve the surgical performance and safety while overcoming the limitations of currently available technology. The proposed 3D haptic guidance allows the surgeon to sense the vasculature while controlling a catheter through a robotic haptic manipulator. Validation of the system is performed through end-user experiments with vascular surgeons on a bespoke surgical simulator. The obtained results demonstrate that 3D haptic guidance has the potential of improving effectiveness, precision, and safety of endovascular intervention. Furthermore, vascular surgeons found the proposed technology safe and overall easy to use, indicating its potential on real surgical procedures.Keywords
This publication has 23 references indexed in Scilit:
- Motion-adapted catheter navigation with real-time instantiation and improved visualisationJournal of Robotic Surgery, 2013
- Haptic Virtual Fixture for Robotic Cardiac Catheter NavigationArtificial Organs, 2011
- Development of a Force‐Reflecting Robotic Platform for Cardiac Catheter NavigationArtificial Organs, 2010
- Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devicesThe International Journal of Medical Robotics and Computer Assisted Surgery, 2010
- Respiratory Displacement of the Thoracic Aorta: Physiological Phenomenon With Potential Implications for Thoracic Endovascular RepairCardioVascular and Interventional Radiology, 2009
- Robot-assisted catheter manipulation for intracardiac navigationInternational Journal of Computer Assisted Radiology and Surgery, 2009
- Haptic feedback in robot-assisted minimally invasive surgeryCurrent Opinion in Urology, 2009
- Finite element modeling of the thoracic aorta: including aortic root motion to evaluate the risk of aortic dissectionJournal of Medical Engineering & Technology, 2008
- Vision-Assisted Control for Manipulation Using Virtual FixturesIEEE Transactions on Robotics, 2004
- Telesurgery System for Intravascular Neurosurgery2000