Wenqiang Chi
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Wenqiang Chi has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
C. Riga
Imperial College London,Department of Surgery Cancer,UK
1 shared publicationCelia Riga
Department of Surgery and Cancer, Imperial College London, St Marys Hospital, London, W2 1NY, UK
1 shared publicationColin Bicknell
Department of Surgery and Cancer, Imperial College London, St Marys Hospital, London, W2 1NY, UK
1 shared publication- Giulio Dagnino
Department of Surgical Sciences, Università degli Studi di Torino, Torino, Italy
1 shared publication Guang-Zhong Yang
Hamlyn Centre for Robotic Surgery, Imperial College London, London, SW7 2AZ, UK
1 shared publication- Guang-Zhong Yang
Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
1 shared publication
Latest Publications
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5398-5403
Haptic Guidance for Robot-Assisted Endovascular Procedures: Implementation and Evaluation on Surgical Simulator
Vascular diseases are the most common precursors to ischemic heart disease and stroke, which are two of the leading causes of death worldwide. Endovascular intervention is a minimally invasive surgical approach to treat such diseases. Compared to open surgery, it has the advantages of faster recovery, reduced need for general anesthesia, reduced blood loss and significantly lower mortality. Endovascular procedures require high surgical skills to minimize contacts between the manipulated instruments (catheters and guidewires) and the vessel wall, which represent one of the major risks for the patient. Robotic assistance can potentially improve the precision and stability of instruments manipulation. One key limitation of current commercial robotic platforms is the lack of haptic feedback, preventing their acceptance and limiting the clinical usability. This paper proposes to bring the benefit of haptic feedback to robot-assisted endovascular intervention. Here we hypothesize that the introduction of 3D haptic guidance during robot-assisted endovascular procedure can further improve the surgical performance and safety while overcoming the limitations of currently available technology. The proposed 3D haptic guidance allows the surgeon to sense the vasculature while controlling a catheter through a robotic haptic manipulator. Validation of the system is performed through end-user experiments with vascular surgeons on a bespoke surgical simulator. The obtained results demonstrate that 3D haptic guidance has the potential of improving effectiveness, precision, and safety of endovascular intervention. Furthermore, vascular surgeons found the proposed technology safe and overall easy to use, indicating its potential on real surgical procedures.
- 1 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 5398-5403
Haptic Guidance for Robot-Assisted Endovascular Procedures: Implementation and Evaluation on Surgical Simulator
Vascular diseases are the most common precursors to ischemic heart disease and stroke, which are two of the leading causes of death worldwide. Endovascular intervention is a minimally invasive surgical approach to treat such diseases. Compared to open surgery, it has the advantages of faster recovery, reduced need for general anesthesia, reduced blood loss and significantly lower mortality. Endovascular procedures require high surgical skills to minimize contacts between the manipulated instruments (catheters and guidewires) and the vessel wall, which represent one of the major risks for the patient. Robotic assistance can potentially improve the precision and stability of instruments manipulation. One key limitation of current commercial robotic platforms is the lack of haptic feedback, preventing their acceptance and limiting the clinical usability. This paper proposes to bring the benefit of haptic feedback to robot-assisted endovascular intervention. Here we hypothesize that the introduction of 3D haptic guidance during robot-assisted endovascular procedure can further improve the surgical performance and safety while overcoming the limitations of currently available technology. The proposed 3D haptic guidance allows the surgeon to sense the vasculature while controlling a catheter through a robotic haptic manipulator. Validation of the system is performed through end-user experiments with vascular surgeons on a bespoke surgical simulator. The obtained results demonstrate that 3D haptic guidance has the potential of improving effectiveness, precision, and safety of endovascular intervention. Furthermore, vascular surgeons found the proposed technology safe and overall easy to use, indicating its potential on real surgical procedures.
- Open Access
- 12 April 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (6) , 855-864
Learning-based endovascular navigation through the use of non-rigid registration for collaborative robotic catheterization
Purpose Endovascular intervention is limited by two-dimensional intraoperative imaging and prolonged procedure times in the presence of complex anatomies. Robotic catheter technology could offer benefits such as reduced radiation exposure to the clinician and improved intravascular navigation. Incorporating three-dimensional preoperative imaging into a semiautonomous robotic catheterization platform has the potential for safer and more precise navigation. This paper discusses a semiautonomous robotic catheter platform based on previous work (Rafii-Tari et al., in: MICCAI2013, pp 369–377. https://doi.org/10.1007/978-3-642-40763-5_46, 2013) by proposing a method to address anatomical variability among aortic arches. It incorporates anatomical information in the process of catheter trajectories optimization, hence can adapt to the scale and orientation differences among patient-specific anatomies. Methods Statistical modeling is implemented to encode the catheter motions of both proximal and distal sites based on cannulation data obtained from a single phantom by an expert operator. Non-rigid registration is applied to obtain a warping function to map catheter tip trajectories into other anatomically similar but shape/scale/orientation different models. The remapped trajectories were used to generate robot trajectories to conduct a collaborative cannulation task under flow simulations. Cross-validations were performed to test the performance of the non-rigid registration. Success rates of the cannulation task executed by the robotic platform were measured. The quality of the catheterization was also assessed using performance metrics for manual and robotic approaches. Furthermore, the contact forces between the instruments and the phantoms were measured and compared for both approaches. Results The success rate for semiautomatic cannulation is 98.1% under dry simulation and 94.4% under continuous flow simulation. The proposed robotic approach achieved smoother catheter paths than manual approach. The mean contact forces have been reduced by 33.3% with the robotic approach, and 70.6% less STDEV forces were observed with the robot. Conclusions This work provides insights into catheter task planning and an improved design of hands-on ergonomic catheter navigation robots.
- 12 April 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (6) , 855-864
Open AccessLearning-based endovascular navigation through the use of non-rigid registration for collaborative robotic catheterization
Purpose Endovascular intervention is limited by two-dimensional intraoperative imaging and prolonged procedure times in the presence of complex anatomies. Robotic catheter technology could offer benefits such as reduced radiation exposure to the clinician and improved intravascular navigation. Incorporating three-dimensional preoperative imaging into a semiautonomous robotic catheterization platform has the potential for safer and more precise navigation. This paper discusses a semiautonomous robotic catheter platform based on previous work (Rafii-Tari et al., in: MICCAI2013, pp 369–377. https://doi.org/10.1007/978-3-642-40763-5_46, 2013) by proposing a method to address anatomical variability among aortic arches. It incorporates anatomical information in the process of catheter trajectories optimization, hence can adapt to the scale and orientation differences among patient-specific anatomies. Methods Statistical modeling is implemented to encode the catheter motions of both proximal and distal sites based on cannulation data obtained from a single phantom by an expert operator. Non-rigid registration is applied to obtain a warping function to map catheter tip trajectories into other anatomically similar but shape/scale/orientation different models. The remapped trajectories were used to generate robot trajectories to conduct a collaborative cannulation task under flow simulations. Cross-validations were performed to test the performance of the non-rigid registration. Success rates of the cannulation task executed by the robotic platform were measured. The quality of the catheterization was also assessed using performance metrics for manual and robotic approaches. Furthermore, the contact forces between the instruments and the phantoms were measured and compared for both approaches. Results The success rate for semiautomatic cannulation is 98.1% under dry simulation and 94.4% under continuous flow simulation. The proposed robotic approach achieved smoother catheter paths than manual approach. The mean contact forces have been reduced by 33.3% with the robotic approach, and 70.6% less STDEV forces were observed with the robot. Conclusions This work provides insights into catheter task planning and an improved design of hands-on ergonomic catheter navigation robots.