The impact of crystal length on calorimeter energy resolution
Open Access
- 25 November 2019
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2178 (1) , 030045
Abstract
Lutetium-yttrium oxyorthosilicate (LYSO) crystal scintillators were originally developed for medical applications. Owing to their high density, small Molière radius, fast response, and high radiation hardness, LYSO crystals have also suitable for future homogeneous electromagnetic calorimeters. Due to these features, LYSO is considered to be used for the electromagnetic calorimeter part of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this research, by employing the GEANT4 toolkit program, we simulated a set of crystal, and their energy resolutions were obtained for different lengths at the energy range of 50 MeV - 2 GeV. Depending on the crystal length, contributions to the constant term of the energy resolution were investigated.Keywords
This publication has 13 references indexed in Scilit:
- Simulation of LYSO Crystal for the TAC-PF Electromagnetic CalorimeterActa Physica Polonica A, 2017
- Design and status of the Mu2e electromagnetic calorimeterNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- Time- and energy-resolution measurements of BaF2, BC-418, LYSO and CeBr3 scintillatorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- Characterization of three LYSO crystal batchesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015
- LYSO crystal calorimeter readout with silicon photomultipliersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- A LYSO calorimeter for the SuperB factoryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Geant4—a simulation toolkitNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2003
- A detailed test of the CsI(Tℓ) calorimeter for BELLE with photon beams of energy between 20 MeV and 5.4 GeVNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- The CLEO detectorNuclear Instruments and Methods in Physics Research, 1983
- Study of the reactionPhysical Review D, 1982