Fatma Kocak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Fatma Kocak has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
I. Tapan
Bursa Uludag Universitesi
6 shared publicationsA. Kilic
Bursa Uludag Universitesi
4 shared publications- A. Abada
Institut National de Physique Nucléaire et de Physique des Particules
2 shared publications A. Afalou
European Organization for Nuclear Research
2 shared publicationsA. Amiri
University of Tehran
2 shared publicationsA. Apresyan
Fermi National Accelerator Laboratory
2 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Erratum to: Future Circular Collider Feasibility Study Report
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessErratum to: Future Circular Collider Feasibility Study Report
- Top Cited PapersOpen Access
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Future Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Top Cited PapersOpen AccessFuture Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- Open Access
- 27 October 2025
- Published by Elsevier in Nuclear Physics B
- Vol. 1021
Comparison of position reconstructions and resolutions obtained by linear and logarithmic weighting methods for a LYSO matrix
- 27 October 2025
- Published by Elsevier in Nuclear Physics B
- Vol. 1021
Open AccessComparison of position reconstructions and resolutions obtained by linear and logarithmic weighting methods for a LYSO matrix
- Open Access
- 18 December 2023
- Published by Prensip Publishing in Journal of Advanced Applied Sciences
- Vol. 2 (2) , 64-67
New Crystal Photodiode Combination for Environmental Radiation Measurement
Here, a new design will be introduced to detect radiation in the environment with high efficiency. The designed structure consists of placing ZnS–Si APD and PIN photodiodes at the ends of conventional crystals such as NaI(Tl) and CsI(Tl). Since ZnS is transparent to photons with wavelengths between 340 and 10000 nm, photons coming from the crystals are absorbed directly in the depletion region and generate primary particles. With an increase in the number of generated primary particles, a stronger and cleaner signal is obtained. In the simulation work, the light generated by 30 keV–3 MeV gamma rays in the crystals was obtained using the Geant4 simulation code. The single-particle Monte Carlo technique was used to calculate the photodiode output signal for the crystal emission spectrum. The simulation results showed that the crystals and ZnS–Si photodiode structures formed a good combination. The high quantum efficiency and low excess noise factor make the ZnS–Si structure an excellent choice for scintillating light detection.
- 18 December 2023
- Published by Prensip Publishing in Journal of Advanced Applied Sciences
- Vol. 2 (2) , 64-67
Open AccessNew Crystal Photodiode Combination for Environmental Radiation Measurement
Here, a new design will be introduced to detect radiation in the environment with high efficiency. The designed structure consists of placing ZnS–Si APD and PIN photodiodes at the ends of conventional crystals such as NaI(Tl) and CsI(Tl). Since ZnS is transparent to photons with wavelengths between 340 and 10000 nm, photons coming from the crystals are absorbed directly in the depletion region and generate primary particles. With an increase in the number of generated primary particles, a stronger and cleaner signal is obtained. In the simulation work, the light generated by 30 keV–3 MeV gamma rays in the crystals was obtained using the Geant4 simulation code. The single-particle Monte Carlo technique was used to calculate the photodiode output signal for the crystal emission spectrum. The simulation results showed that the crystals and ZnS–Si photodiode structures formed a good combination. The high quantum efficiency and low excess noise factor make the ZnS–Si structure an excellent choice for scintillating light detection.
- Open Access
- 14 September 2021
- Published by Hindawi Limited in Advances in High Energy Physics
- Vol. 2021, 1-5
Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
LYSO scintillation crystals, due to their significant characteristics such as high light yield, fast decay time, small Moliére radius, and good radiation hardness, are proposed to be used for the electromagnetic calorimeter section of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this work, the center of gravity technique was used to determine the impact coordinates of an electron initiating an electromagnetic shower in a LYSO array, in a calorimeter module containing nine crystals, each 25 mm × 25 mm in cross-section and 200 mm in length. The response of the calorimeter module has been studied with electrons having energies in the range 0.1 GeV-2 GeV. By using the Monte Carlo simulation based on Geant4, the two-dimensional position resolution of the module is obtained as σ R mm = 3.95 ± 0.08 / E ⊕ 1.91 ± 0.11 at the center of the crystal.
- 14 September 2021
- Published by Hindawi Limited in Advances in High Energy Physics
- Vol. 2021, 1-5
Open AccessDetermination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
LYSO scintillation crystals, due to their significant characteristics such as high light yield, fast decay time, small Moliére radius, and good radiation hardness, are proposed to be used for the electromagnetic calorimeter section of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this work, the center of gravity technique was used to determine the impact coordinates of an electron initiating an electromagnetic shower in a LYSO array, in a calorimeter module containing nine crystals, each 25 mm × 25 mm in cross-section and 200 mm in length. The response of the calorimeter module has been studied with electrons having energies in the range 0.1 GeV-2 GeV. By using the Monte Carlo simulation based on Geant4, the two-dimensional position resolution of the module is obtained as σ R mm = 3.95 ± 0.08 / E ⊕ 1.91 ± 0.11 at the center of the crystal.
- Open Access
Evaluation of Energy Resolution by Changing Angle and Position of Incident Photon in a LYSO Calorimeter
In this paper, we investigate the effect on energy resolution from changing the angle and the position of incidence photon for a 5 $\times$ 5 crystal matrix built with (25 $\times$ 25 $\times$ 200) mm$^{3}$ LYSO scintillating crystals. Those crystals have been proposed for the electromagnetic calorimeter of the Turkish Accelerator Center-Particle Factory (TAC-PF) detector. The energy resolution was obtained as $\sigma_{E}/E = 0.42 \% / \sqrt{E/GeV} \oplus 1.60 \%$ at the center of the matrix in the energy range of 50 MeV to 2 GeV. When we examined the dependence of the energy resolution on the incidence angle of the photon, resolution began to deteriorate at angles greater than $2^{\circ}$ on the 5 $\times$ 5 crystal matrix. Moreover, energy resolution at the corners of the central crystal was worse than at the center of the central crystal by a factor of 1.3 at 50 MeV and 1.1 at 2 GeV.Open AccessEvaluation of Energy Resolution by Changing Angle and Position of Incident Photon in a LYSO Calorimeter
In this paper, we investigate the effect on energy resolution from changing the angle and the position of incidence photon for a 5 $\times$ 5 crystal matrix built with (25 $\times$ 25 $\times$ 200) mm$^{3}$ LYSO scintillating crystals. Those crystals have been proposed for the electromagnetic calorimeter of the Turkish Accelerator Center-Particle Factory (TAC-PF) detector. The energy resolution was obtained as $\sigma_{E}/E = 0.42 \% / \sqrt{E/GeV} \oplus 1.60 \%$ at the center of the matrix in the energy range of 50 MeV to 2 GeV. When we examined the dependence of the energy resolution on the incidence angle of the photon, resolution began to deteriorate at angles greater than $2^{\circ}$ on the 5 $\times$ 5 crystal matrix. Moreover, energy resolution at the corners of the central crystal was worse than at the center of the central crystal by a factor of 1.3 at 50 MeV and 1.1 at 2 GeV. - 1 January 2020
- Published by Jagiellonian University in Acta Physica Polonica B
- Vol. 51 (11)
EVALUATION OF ENERGY RESOLUTION BY CHANGING ANGLE AND POSITION OF INCIDENT PHOTON IN A LYSO CALORIMETER
- 1 January 2020
- Published by Jagiellonian University in Acta Physica Polonica B
- Vol. 51 (11)
EVALUATION OF ENERGY RESOLUTION BY CHANGING ANGLE AND POSITION OF INCIDENT PHOTON IN A LYSO CALORIMETER
- Open Access
- 25 November 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2178 (1) , 030045
The impact of crystal length on calorimeter energy resolution
Lutetium-yttrium oxyorthosilicate (LYSO) crystal scintillators were originally developed for medical applications. Owing to their high density, small Molière radius, fast response, and high radiation hardness, LYSO crystals have also suitable for future homogeneous electromagnetic calorimeters. Due to these features, LYSO is considered to be used for the electromagnetic calorimeter part of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this research, by employing the GEANT4 toolkit program, we simulated a set of crystal, and their energy resolutions were obtained for different lengths at the energy range of 50 MeV - 2 GeV. Depending on the crystal length, contributions to the constant term of the energy resolution were investigated.
- 25 November 2019
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2178 (1) , 030045
Open AccessThe impact of crystal length on calorimeter energy resolution
Lutetium-yttrium oxyorthosilicate (LYSO) crystal scintillators were originally developed for medical applications. Owing to their high density, small Molière radius, fast response, and high radiation hardness, LYSO crystals have also suitable for future homogeneous electromagnetic calorimeters. Due to these features, LYSO is considered to be used for the electromagnetic calorimeter part of the Turkish Accelerator Center Particle Factory (TAC-PF) detector. In this research, by employing the GEANT4 toolkit program, we simulated a set of crystal, and their energy resolutions were obtained for different lengths at the energy range of 50 MeV - 2 GeV. Depending on the crystal length, contributions to the constant term of the energy resolution were investigated.
- 1 March 2017
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 131 (3) , 527-530
Simulation of LYSO Crystal for the TAC-PF Electromagnetic Calorimeter
- 1 March 2017
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 131 (3) , 527-530
Simulation of LYSO Crystal for the TAC-PF Electromagnetic Calorimeter
- 1 January 2017
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 131 (1) , 190-192
Radiaton Effects on TAC-PF Electromagnetic Calorimeter
- 1 January 2017
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 131 (1) , 190-192
Radiaton Effects on TAC-PF Electromagnetic Calorimeter