Sub-millisecond time-resolved SAXS using a continuous-flow mixer and X-ray microbeam
Open Access
- 1 October 2013
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 20 (6) , 820-825
Abstract
Small-angle X-ray scattering (SAXS) is a well established technique to probe the nanoscale structure and interactions in soft matter. It allows one to study the structure of native particles in near physiological environments and to analyze structural changes in response to variations in external conditions. The combination of microfluidics and SAXS provides a powerful tool to investigate dynamic processes on a molecular level with sub-millisecond time resolution. Reaction kinetics in the sub-millisecond time range has been achieved using continuous-flow mixers manufactured using micromachining techniques. The time resolution of these devices has previously been limited, in part, by the X-ray beam sizes delivered by typical SAXS beamlines. These limitations can be overcome using optics to focus X-rays to the micrometer size range providing that beam divergence and photon flux suitable for performing SAXS experiments can be maintained. Such micro-SAXS in combination with microfluidic devices would be an attractive probe for time-resolved studies. Here, the development of a high-duty-cycle scanning microsecond-time-resolution SAXS capability, built around the Kirkpatrick-Baez mirror-based microbeam system at the Biophysics Collaborative Access Team (BioCAT) beamline 18ID at the Advanced Photon Source, Argonne National Laboratory, is reported. A detailed description of the microbeam small-angle-scattering instrument, the turbulent flow mixer, as well as the data acquisition and control and analysis software is provided. Results are presented where this apparatus was used to study the folding of cytochrome c. Future prospects for this technique are discussed.Keywords
This publication has 30 references indexed in Scilit:
- Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXASJournal of Synchrotron Radiation, 2010
- Microsecond Hydrophobic Collapse in the Folding of Escherichia coli Dihydrofolate Reductase, an α/β-Type ProteinJournal of Molecular Biology, 2007
- A microchannel solution mixer for studying microsecond protein folding reactionsReview of Scientific Instruments, 2004
- The BioCAT undulator beamline 18ID: a facility for biological non-crystalline diffraction and X-ray absorption spectroscopy at the Advanced Photon SourceJournal of Synchrotron Radiation, 2004
- SecA Folding Kinetics: A Large Dimeric Protein Rapidly Forms Multiple Native StatesJournal of Molecular Biology, 2004
- Measurement of microsecond dynamic motion in the intestinal fatty acid binding protein by using fluorescence correlation spectroscopyProceedings of the National Academy of Sciences, 2002
- Conformational landscape of cytochrome c folding studied by microsecond-resolved small-angle x-ray scatteringProceedings of the National Academy of Sciences, 2002
- Dynamically figured Kirkpatrick Baez x-ray microfocusing optics1998
- Submillisecond protein folding kinetics studied by ultrarapid mixingProceedings of the National Academy of Sciences, 1997
- The Radius of Gyration of an Apomyoglobin Folding IntermediateScience, 1995