Fast-scanning high-flux microprobe for biological X-ray fluorescence microscopy and microXAS
- 26 May 2010
- journal article
- research article
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 17 (4) , 522-529
Abstract
There is a growing interest in the biomedical community in obtaining information concerning the distribution and local chemical environment of metals in tissues and cells. Recently, biological X-ray fluorescence microscopy (XFM) has emerged as the tool of choice to address these questions. A fast-scanning high-flux X-ray microprobe, built around a recently commissioned pair of 200 mm-long Rh-coated silicon Kirkpatrick-Baez mirrors, has been constructed at BioCAT beamline 18ID at the Advanced Photon Source. The new optical system delivers a flux of 1.3 x 10(12) photons s(-1) into a minimum focal spot size of approximately 3-5 microm FWHM. A set of Si drift detectors and bent Laue crystal analyzers may be used in combination with standard ionization chambers for X-ray fluorescence measurements. BioCAT's scanning software allows fast continuous scans to be performed while acquiring and storing full multichannel analyzer spectra per pixel on-the-fly with minimal overhead time (<20 ms per pixel). Together, the high-flux X-ray microbeam and the rapid-scanning capabilities of the BioCAT beamline allow the collection of XFM and micro X-ray absorption spectroscopy (microXAS) measurements from as many as 48 tissue sections per day. This paper reports the commissioning results of the new instrument with representative XFM and microXAS results from tissue samples.Keywords
This publication has 19 references indexed in Scilit:
- Zinc and prostatic cancerCurrent Opinion in Clinical Nutrition and Metabolic Care, 2009
- Disturbed homeostasis of zinc and other essential elements in the prostate gland dependent on the character of pathological lesionsBioMetals, 2009
- Synchrotron X‐ray imaging reveals a correlation of tumor copper speciation with Clioquinol's anticancer activityJournal of Cellular Biochemistry, 2009
- Biological applications of X-ray microprobesInternational Journal of Radiation Biology, 2009
- High-energy x-ray microbeam with total-reflection mirror opticsReview of Scientific Instruments, 2007
- X‐ray fluorescence microprobe imaging in biology and medicineJournal of Cellular Biochemistry, 2006
- ATHENA,ARTEMIS,HEPHAESTUS: data analysis for X-ray absorption spectroscopy usingIFEFFITJournal of Synchrotron Radiation, 2005
- The BioCAT undulator beamline 18ID: a facility for biological non-crystalline diffraction and X-ray absorption spectroscopy at the Advanced Photon SourceJournal of Synchrotron Radiation, 2004
- Beamline 10.3.2 at ALS: a hard X-ray microprobe for environmental and materials sciencesJournal of Synchrotron Radiation, 2004
- A bent Laue analyzer for fluorescence EXAFS detectionJournal of Synchrotron Radiation, 1999