Local SAR management strategies to use two‐channel RF shimming for fetal MRI at 3 T
- 6 November 2023
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 1165-1178
Abstract
Purpose: This study evaluates the imaging performance of two‐channel RF‐shimming for fetal MRI at 3 T using four different local specific absorption rate (SAR) management strategies.Methods: Due to the ambiguity of safe local SAR levels for fetal MRI, local SAR limits for RF shimming were determined based on either each individual's own SAR levels in standard imaging mode (CP mode) or the maximum SAR level observed across seven pregnant body models in CP mode. Local SAR was constrained either indirectly by further constraining the whole‐body SAR (wbSAR) or directly by using subject‐specific local SAR models. Each strategy was evaluated by the improvement of the transmit field efficiency (average |B1+|) and nonuniformity (|B1+| variation) inside the fetus compared with CP mode for the same wbSAR.Results: Constraining wbSAR when using RF shimming decreases B1+ efficiency inside the fetus compared with CP mode (by 12%–30% on average), making it inefficient for SAR management. Using subject‐specific models with SAR limits based on each individual's own CP mode SAR value, B1+ efficiency and nonuniformity are improved on average by 6% and 13% across seven pregnant models. In contrast, using SAR limits based on maximum CP mode SAR values across seven models, B1+ efficiency and nonuniformity are improved by 13% and 25%, compared with the best achievable improvement without SAR constraints: 15% and 26%.Conclusion: Two‐channel RF‐shimming can safely and significantly improve the transmit field inside the fetus when subject‐specific models are used with local SAR limits based on maximum CP mode SAR levels in the pregnant population.Keywords
Funding Information
- National Institutes of Health (R01EB006847, R01EB017337, R01HD100009, U01HD087211, R01EB032708)
This publication has 32 references indexed in Scilit:
- On Variant Strategies to Solve the Magnitude Least Squares Optimization Problem in Parallel Transmission Pulse Design and Under Strict SAR and Power ConstraintsIEEE Transactions on Medical Imaging, 2013
- Whole‐body and local RF absorption in human models as a function of anatomy and position within 1.5T MR body coilMagnetic Resonance in Medicine, 2013
- Thresholds for thermal damage to normal tissues: An updateInternational Journal of Hyperthermia, 2011
- Safety of Fetal MRI Scanning2010
- A Review of MR Physics: 3T versus 1.5TMagnetic Resonance Imaging Clinics of North America, 2007
- Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancyMagnetic Resonance in Medicine, 2006
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005
- MEDICAL MAGNETIC RESONANCE (MR) PROCEDURES: PROTECTION OF PATIENTSHealth Physics, 2004
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Transmit SENSEMagnetic Resonance in Medicine, 2002