Filiz Yetisir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Filiz Yetisir has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Elfar Adalsteinsson
Harvard‐MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology Cambridge Massachusetts USA
4 shared publicationsP. Ellen Grant
Department of Pediatrics Harvard Medical School Boston Massachusetts USA
3 shared publicationsBastien Guerin
Department of Radiology, Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA; Athinoula A. Martinos Center for Biomedical Imaging, MA General Hospital, 149 13th Street, Charlestown, MA 02129, USA
2 shared publications- Borjan Gagoski
Department of Radiology Harvard Medical School Boston Massachusetts USA
2 shared publications - Esra Abaci Turk
Fetal-Neonatal Neuroimaging & Developmental Science Center, Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
2 shared publications Lawrence L. Wald
Department of Radiology, Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA; Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, 77 MA Avenue, Cambridge, MA 02139, USA; Athinoula A. Martinos Center for Biomedical Imaging, MA General Hospital, 149 13th Street, Charlestown, MA 02129, USA
2 shared publications
Latest Publications
- 17 April 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (3) , 844-853
Fetal MRI: Radiofrequency Safety Assessment at 3 Tesla
Background: 3‐T MRI can improve image quality of fetal imaging compared to 1.5‐T MRI. However, concerns exist regarding increased local tissue heating at 3‐T.Purpose: To assess fetal MRI radiofrequency (RF) safety at 3‐T by comparing simulated tissue heating to 1.5‐T (using constant RF exposure) and by simulating tissue heating at 3‐T using RF exposures from clinical fetal examinations.Study Type: Retrospective.Population: Seven voxelized anatomical pregnant body models (gestational age [GA] 30 ± 3 weeks [mean ± standard deviation], maternal body mass index [BMI] 27.8 ± 8.5 kg/m2) were used. Maternal whole‐body average specific absorption rate (wbSAR) logs were collected from 85 clinical examinations at 3‐T (GA 25 ± 6 weeks, BMI 30.3 ± 6.8 kg/m2).Field Strength/Sequence: 3‐T, 1.5‐T, HASTE, VIBE, TRUFISP, EPI, DTI.Assessment: Simulated maternal and fetal peak and average SAR, temperature, and peak thermal dose were compared at 3‐T and 1.5‐T for 60 min 2 W/kg wbSAR using 7 body models and a 16‐rung band‐pass RF coil. Temperature and thermal dose were simulated in one body model using clinical wbSAR exposures at 3‐T.Statistical Tests: Factorial analysis of variance was performed using 28 maternal and fetal temperature measurements from 7 body models to detect a difference between 3‐T and 1.5‐T. p < 0.05 was considered statistically significant.Results: For constant RF exposure, we found no difference between 3‐T and 1.5‐T in peak maternal (1.5‐T:40.38 ± 0.21°C; 3‐T:40.40 ± 0.20°C; p = 0.85), peak fetal (1.5‐T:39.21 ± 0.17°C; 3‐T:39.09 ± 0.16°C; p = 0.19), and average maternal (1.5‐T:37.32 ± 0.05°C; 3‐T:37.33 ± 0.04°C; p = 0.68) temperature. We observed significantly higher average fetal temperatures at 1.5‐T (1.5‐T:37.75 ± 0.06°C; 3‐T:37.70 ± 0.05°C). For 3‐T clinical RF exposures, simulated peak temperatures exceeded the recommended limits. However, the thermal dose was below the recommended limit.Data Conclusion: For the same RF coil geometry, local heating was similar at 3‐T and 1.5‐T for constant RF exposure. Although realistic 3‐T RF exposures could cause peak temperatures above the recommended limits, thermal dose was below the recommended limit.Evidence Level: 1.Technical Efficacy: Stage 1.
- 17 April 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 62 (3) , 844-853
Fetal MRI: Radiofrequency Safety Assessment at 3 Tesla
Background: 3‐T MRI can improve image quality of fetal imaging compared to 1.5‐T MRI. However, concerns exist regarding increased local tissue heating at 3‐T.Purpose: To assess fetal MRI radiofrequency (RF) safety at 3‐T by comparing simulated tissue heating to 1.5‐T (using constant RF exposure) and by simulating tissue heating at 3‐T using RF exposures from clinical fetal examinations.Study Type: Retrospective.Population: Seven voxelized anatomical pregnant body models (gestational age [GA] 30 ± 3 weeks [mean ± standard deviation], maternal body mass index [BMI] 27.8 ± 8.5 kg/m2) were used. Maternal whole‐body average specific absorption rate (wbSAR) logs were collected from 85 clinical examinations at 3‐T (GA 25 ± 6 weeks, BMI 30.3 ± 6.8 kg/m2).Field Strength/Sequence: 3‐T, 1.5‐T, HASTE, VIBE, TRUFISP, EPI, DTI.Assessment: Simulated maternal and fetal peak and average SAR, temperature, and peak thermal dose were compared at 3‐T and 1.5‐T for 60 min 2 W/kg wbSAR using 7 body models and a 16‐rung band‐pass RF coil. Temperature and thermal dose were simulated in one body model using clinical wbSAR exposures at 3‐T.Statistical Tests: Factorial analysis of variance was performed using 28 maternal and fetal temperature measurements from 7 body models to detect a difference between 3‐T and 1.5‐T. p < 0.05 was considered statistically significant.Results: For constant RF exposure, we found no difference between 3‐T and 1.5‐T in peak maternal (1.5‐T:40.38 ± 0.21°C; 3‐T:40.40 ± 0.20°C; p = 0.85), peak fetal (1.5‐T:39.21 ± 0.17°C; 3‐T:39.09 ± 0.16°C; p = 0.19), and average maternal (1.5‐T:37.32 ± 0.05°C; 3‐T:37.33 ± 0.04°C; p = 0.68) temperature. We observed significantly higher average fetal temperatures at 1.5‐T (1.5‐T:37.75 ± 0.06°C; 3‐T:37.70 ± 0.05°C). For 3‐T clinical RF exposures, simulated peak temperatures exceeded the recommended limits. However, the thermal dose was below the recommended limit.Data Conclusion: For the same RF coil geometry, local heating was similar at 3‐T and 1.5‐T for constant RF exposure. Although realistic 3‐T RF exposures could cause peak temperatures above the recommended limits, thermal dose was below the recommended limit.Evidence Level: 1.Technical Efficacy: Stage 1.
- 6 November 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 1165-1178
Local SAR management strategies to use two‐channel RF shimming for fetal MRI at 3 T
Purpose: This study evaluates the imaging performance of two‐channel RF‐shimming for fetal MRI at 3 T using four different local specific absorption rate (SAR) management strategies.Methods: Due to the ambiguity of safe local SAR levels for fetal MRI, local SAR limits for RF shimming were determined based on either each individual's own SAR levels in standard imaging mode (CP mode) or the maximum SAR level observed across seven pregnant body models in CP mode. Local SAR was constrained either indirectly by further constraining the whole‐body SAR (wbSAR) or directly by using subject‐specific local SAR models. Each strategy was evaluated by the improvement of the transmit field efficiency (average |B1+|) and nonuniformity (|B1+| variation) inside the fetus compared with CP mode for the same wbSAR.Results: Constraining wbSAR when using RF shimming decreases B1+ efficiency inside the fetus compared with CP mode (by 12%–30% on average), making it inefficient for SAR management. Using subject‐specific models with SAR limits based on each individual's own CP mode SAR value, B1+ efficiency and nonuniformity are improved on average by 6% and 13% across seven pregnant models. In contrast, using SAR limits based on maximum CP mode SAR values across seven models, B1+ efficiency and nonuniformity are improved by 13% and 25%, compared with the best achievable improvement without SAR constraints: 15% and 26%.Conclusion: Two‐channel RF‐shimming can safely and significantly improve the transmit field inside the fetus when subject‐specific models are used with local SAR limits based on maximum CP mode SAR levels in the pregnant population.
- 6 November 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (3) , 1165-1178
Local SAR management strategies to use two‐channel RF shimming for fetal MRI at 3 T
Purpose: This study evaluates the imaging performance of two‐channel RF‐shimming for fetal MRI at 3 T using four different local specific absorption rate (SAR) management strategies.Methods: Due to the ambiguity of safe local SAR levels for fetal MRI, local SAR limits for RF shimming were determined based on either each individual's own SAR levels in standard imaging mode (CP mode) or the maximum SAR level observed across seven pregnant body models in CP mode. Local SAR was constrained either indirectly by further constraining the whole‐body SAR (wbSAR) or directly by using subject‐specific local SAR models. Each strategy was evaluated by the improvement of the transmit field efficiency (average |B1+|) and nonuniformity (|B1+| variation) inside the fetus compared with CP mode for the same wbSAR.Results: Constraining wbSAR when using RF shimming decreases B1+ efficiency inside the fetus compared with CP mode (by 12%–30% on average), making it inefficient for SAR management. Using subject‐specific models with SAR limits based on each individual's own CP mode SAR value, B1+ efficiency and nonuniformity are improved on average by 6% and 13% across seven pregnant models. In contrast, using SAR limits based on maximum CP mode SAR values across seven models, B1+ efficiency and nonuniformity are improved by 13% and 25%, compared with the best achievable improvement without SAR constraints: 15% and 26%.Conclusion: Two‐channel RF‐shimming can safely and significantly improve the transmit field inside the fetus when subject‐specific models are used with local SAR limits based on maximum CP mode SAR levels in the pregnant population.
- 5 August 2022
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 93, 87-96
Parallel transmission 2D RARE imaging at 7T with transmit field inhomogeneity mitigation and local SAR control
- 5 August 2022
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 93, 87-96
Parallel transmission 2D RARE imaging at 7T with transmit field inhomogeneity mitigation and local SAR control
- 9 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2810-2821
Safety and imaging performance of two‐channel RF shimming for fetal MRI at 3T
Purpose: This study investigates whether two‐channel radiofrequency (RF) shimming can improve imaging without increasing specific absorption rate (SAR) for fetal MRI at 3T.Methods: Transmit field () average and variation in the fetus was simulated in seven numerical pregnant body models. Safety was quantified by maternal and fetal peak local SAR and fetal average SAR. The shim parameter space was divided into improved (magnitude and homogeneity) and improved SAR regions, and an overlap where RF shimming improved both classes of metrics compared with birdcage mode was assessed. Additionally, the effect of fetal position, tissue detail, and dielectric properties on transmit field and SAR was studied.Results: A region of subject‐specific RF shim parameter space improving both and SAR metrics was found for five of the seven models. Optimizing only metrics improved efficiency across models by 15% on average and 28% for the best‐case model. variation improved by 26% on average and 49% for the best case. However, for these shim settings, fetal SAR increased by up to 106%. The overlap region, where both and SAR metrics improve, showed an average efficiency improvement of 6% on average across models and 19% for the best‐case model. variation improved by 13% on average and 40% for the best case. RFS could also decrease maternal/fetal SAR by up to 49%/58%.Conclusion: RF shimming can improve imaging compared with birdcage mode without increasing fetal and maternal SAR when a patient‐specific SAR model is incorporated into the shimming procedure.
- 9 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2810-2821
Safety and imaging performance of two‐channel RF shimming for fetal MRI at 3T
Purpose: This study investigates whether two‐channel radiofrequency (RF) shimming can improve imaging without increasing specific absorption rate (SAR) for fetal MRI at 3T.Methods: Transmit field () average and variation in the fetus was simulated in seven numerical pregnant body models. Safety was quantified by maternal and fetal peak local SAR and fetal average SAR. The shim parameter space was divided into improved (magnitude and homogeneity) and improved SAR regions, and an overlap where RF shimming improved both classes of metrics compared with birdcage mode was assessed. Additionally, the effect of fetal position, tissue detail, and dielectric properties on transmit field and SAR was studied.Results: A region of subject‐specific RF shim parameter space improving both and SAR metrics was found for five of the seven models. Optimizing only metrics improved efficiency across models by 15% on average and 28% for the best‐case model. variation improved by 26% on average and 49% for the best case. However, for these shim settings, fetal SAR increased by up to 106%. The overlap region, where both and SAR metrics improve, showed an average efficiency improvement of 6% on average across models and 19% for the best‐case model. variation improved by 13% on average and 40% for the best case. RFS could also decrease maternal/fetal SAR by up to 49%/58%.Conclusion: RF shimming can improve imaging compared with birdcage mode without increasing fetal and maternal SAR when a patient‐specific SAR model is incorporated into the shimming procedure.