Outcomes of a Refractive Segmented Bifocal Intraocular Lens with a Lower Near Addition
Open Access
- 10 August 2022
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 16, 2531-2543
Abstract
Purpose: To evaluate clinical and subjective outcomes of a segmented bifocal IOL with a 2.0 D near addition. Patients and Methods: Retrospective analyses of patients who had undergone refractive lens exchange with bilateral implantation of the SBL-2 IOL (Lenstec, Inc., Christ Church, Barbados) were performed. The number of patients included in the study was 389 (778 eyes). Refractive, visual and patient-reported outcomes were presented for the last available visit (mean follow-up 2.05 ± 1.33 months). Results: The percentage of eyes within ± 0.50D and ± 1.00D of emmetropia was 82.5% (642/778) and 97.8% (761/778), respectively. The mean uncorrected intermediate visual acuity (66 cm) of the last available visit was 0.08 ± 0.15 logMAR monocularly and 0.04 ± 0.14 logMAR binocularly. The mean monocular and binocular uncorrected near visual acuity (40 cm) were 0.30 ± 0.15 logMAR and 0.24 ± 0.14 logMAR, respectively. Of all patients, 97.2% (378/389) claimed never to use any correction for distance vision, while 93.1% (362/389) of patients did not require any correction for near vision. The mean scores for visual phenomena (on the scale from 1 – no difficulty to 7 – severe difficulty) were 1.8 ± 1.3, 1.7 ± 1.2, 1.7 ± 1.2 and 1.6 ± 1.2 for glare, halo, starburst, and ghosting/double vision, respectively. Conclusion: Despite the lower near addition of SBL-2 segmented bifocal IOL, patients achieved reasonable rates of spectacle independence and a low incidence of visual phenomena.Keywords
This publication has 29 references indexed in Scilit:
- Visual Outcome and Patient Satisfaction of Low-Power-Added Multifocal Intraocular LensEye & Contact Lens: Science & Clinical Practice, 2018
- Symptoms and Satisfaction of Patients in the Patient-Reported Outcomes With Laser In Situ Keratomileusis (PROWL) StudiesJAMA Ophthalmology, 2017
- Rotationally asymmetric multifocal intraocular lensesCurrent Opinion in Ophthalmology, 2017
- Comparison of the visual performance and quality of vision with combined symmetrical inferonasal near addition versus inferonasal and superotemporal placement of rotationally asymmetric refractive multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2016
- Role of the treating surgeon in the consent process for elective refractive surgeryClinical Ophthalmology, 2016
- Optimized Visual Outcome After Asymmetrical Multifocal IOL RotationJournal of Refractive Surgery, 2016
- Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publicationsJournal of Cataract & Refractive Surgery, 2016
- Effect of postoperative keratometry on quality of vision in the postoperative period after myopic wavefront-guided laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2015
- Initial Experience With a New Refractive Rotationally Asymmetric Multifocal Intraocular LensJournal of Refractive Surgery, 2014
- Visual outcomes and patient satisfaction in 9366 eyes using a refractive segmented multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2013