  • Primary calcification of hydrophilic acrylic lenses in a large population: incidence and outcomes of lens exchange procedures

    by Dimitris Kazakos, Jan A. Venter, Stephen J. Hannan, David Teenan, David R. Cooper, Steven C. Schallhorn, Colin W. Berry, Noelle C. Hannan, Dasi Raju, Julie M. Schallhorn

    Purpose: To assess the incidence of primary opacification and analyze the outcomes of intraocular lens (IOL) exchange procedures. Setting: Private clinics, United Kingdom. Design: Retrospective study. Methods: Electronic charts of all patients implanted with LENTIS lenses between 2010 and 2015 were reviewed, and the incidence of opacification was calculated. The data of patients who developed opacification were compared with those who did not. In eyes requiring IOL exchange due to opacification, visual and refractive outcomes of the last available postexchange visit were analyzed. The analysis was performed separately for eyes with multifocal and monofocal secondary IOLs. Results: 47 171 LENTIS IOLs were implanted of which 2426 (5.1%) opacified. Of the opacified lenses, 1568 (3.3% of the whole cohort) required an IOL exchange. The mean time from primary treatment to opacification diagnosis was 6.9 ± 2.2 years. Patients who developed opacification had a higher prevalence of preoperative myopia. Of all eyes requiring an IOL exchange, the secondary IOL was monofocal in 43.0% and multifocal in 57.0% of eyes. Postexchange corrected visual acuity was 0.00 ± 0.13 logMAR (20/20) in eyes with monofocal secondary IOLs and −0.02 ± 0.08 logMAR (20/20 +1 ) in eyes with multifocal secondary IOLs. The final anatomical position of the secondary IOL was as follows: in-the-bag fixation 67.9%, ciliary sulcus fixation 30.1%, iris-claw fixation 0.6%, and iris suturing or scleral fixation 1.4%. Conclusions: Exchange of opacified IOL was performed safely in most of the patients who developed opacification, including those with prior Nd:YAG capsulotomy, with good visual and refractive outcomes.

  • Top Cited Papers

    The incidence and outcomes of intraocular lens exchanges in patients dissatisfied with multifocal lenses: a 15-year retrospective dataset analysis

    by Dimitris Kazakos, Stephen J. Hannan, Jan A. Venter, David Teenan, Huba J. Kiss, Noelle C. Hannan, Colin W. Berry, David R. Cooper, Dasi Raju, Steven C. Schallhorn, et al.

    Purpose: To assess the incidence, clinical outcomes, and adverse event rates of intraocular lens exchange in patients dissatisfied with presbyopia-correcting multifocal IOLs. Setting: Private clinics, United Kingdom Design: Retrospective study Methods: Data of patients who underwent multifocal IOL implantation between 2007 and 2021 and required the exchange of intraocular lenses due to quality of vision issues or insufficient near vision were reviewed. IOL exchanges for other reasons (dislocation, opacification, or other adverse events) were not included in the analysis. Visual and refractive outcomes of the lens exchange procedure were analyzed for the last available follow-up. Results: The mean time from the primary procedure to the IOL exchange was 13.6±8.3 months. The total IOL exchange rate was 0.63% (688 of 109,274 lenses). Of these, 637 exchanges (0.58%) were performed due to quality of vision issues, and 51 (0.05%) were exchanged primarily due to insufficient near vision (e.g., IOL with lower near addition exchanged for an IOL with stronger near addition). Post IOL exchange, 71.7% (493/688) and 91.3% (628/688) were within 0.50D and 1.00D of emmetropia, respectively. The mean post-exchange uncorrected distance visual acuity was 0.11±0.21 logMAR (20/25 -0.5 ). The anatomical position of the secondary IOL was as follows: in-the-bag fixation 86.8% (597/688), ciliary sulcus fixation 12.5% (86/688), and alternative fixation (iris claw, scleral fixation, or IOL suturing) was used in 0.7% of cases (5/688). Conclusion: Patients requiring an IOL exchange due to dissatisfaction with multifocal lenses achieved favorable refractive and visual outcomes. In-the-bag implantation of secondary IOL was possible in most cases.


  • Open Access

    Clinical Outcomes of an Enhanced and Conventional Monofocal IOL in Patients with Early and Intermediate Dry Age-Related Macular Degeneration

    by Jan Venter, Colin W Berry, Noelle C Hannan, Dasi Raju, Huba J Kiss, Mirna Belovari, Stephen J Hannan, David R Cooper, Julie M Schallhorn

    Purpose: To compare the performance of an enhanced and conventional monofocal IOL in eyes with early and intermediate age-related macular degeneration (AMD). Methods: This retrospective study compared one-month postoperative outcomes of patients bilaterally implanted with TECNIS Eyhance IOL (ICB00 group) or TECNIS Monofocal IOL (ZCB00 group). All patients underwent cataract surgery with pre-existing early or intermediate dry AMD. Outcome measures were monocular and binocular uncorrected distance (UDVA), intermediate (UIVA) and near (UNVA) visual acuity, monocular corrected distance visual acuity (CDVA), and refractive outcomes. Monocular visual acuities and refractive predictability were calculated for the dominant eye of each patient. Results: The ICB00 group comprised 143 eyes of 143 patients, while 164 eyes of 164 patients were included in the ZCB00 group. Preoperative characteristics were comparable between the two groups. There was no significant difference in postoperative refractive predictability, with 87.4% and 89.6% of eyes within 0.50 D of emmetropia in the ICB00 and ZCB00 groups, respectively (p=0.54). No difference was found in postoperative UDVA or CDVA between the groups. Both monocular and binocular UIVA were significantly better in the ICB00 group (monocular UIVA: 0.32± 0.19 vs 0.42± 0.22 logMAR, p< 0.001; binocular UIVA: 0.25± 0.18 vs 0.36± 0.17 logMAR, p< 0.001). Postoperative UNVA was also better with the ICB00 IOL (monocular UNVA: 0.58± 0.16 vs 0.69± 0.20 logMAR, p< 0.001; binocular UNVA: 0.50± 0.16 vs 0.63± 0.17 logMAR, p< 0.001). Conclusion: ICB00 IOL enhanced intermediate and near vision in patients with AMD while achieving the same level of corrected and uncorrected distance visual acuity.


  • Open Access

    Preliminary Evaluation of Clinical and Non-Clinical Outcome Metrics in Patient Satisfaction After Implantation of a Non-Constant Aberration-Correcting Monofocal IOL

    by Steven C Schallhorn, David Teenan, Jan Venter, Julie M Schallhorn, Stephen J Hannan

    Purpose: To evaluate patient-reported outcomes after implantation of a non-constant aberration-correcting monofocal IOL and explore factors affecting postoperative satisfaction with vision. Methods: This retrospective study comprised patients who underwent cataract surgery with bilateral implantation of CT LUCIA 621P IOL (Carl Zeiss Meditec AG, Jena, Germany). Factors affecting postoperative satisfaction with vision were evaluated, including patient demographics, clinical and non-clinical variables (visual acuities, adverse events, ocular comorbidities, general health, depression scores, personality types), and other patient-reported outcomes (visual phenomena, dry eye). Questionnaires were used to assess patient-reported visual outcomes, depression, and personality types. The outcomes of the last available clinical visit were evaluated. Results: A total of 97 patients were included, of whom 63.9% reported to be very satisfied and 30.9% were satisfied with postoperative vision. Only three patients were dissatisfied, and the reasons were mostly related to their postoperative clinical findings. In a multivariate logistic regression analysis, the patient’s age and postoperative uncorrected visual acuity were significant predictors of postoperative satisfaction. Some non-clinical and clinical variables were signaling potential trends in satisfaction, but a larger cohort of patients would be required to explore them. Conclusion: Satisfaction of cataract patients implanted with a monofocal IOL remains high. When evaluating postoperative satisfaction, non-clinical factors and interactions with other patient-reported outcomes (visual phenomena or dry eye) should not be underestimated.


  • Effect of residual sphere on uncorrected visual acuity and satisfaction in patients with monofocal and multifocal intraocular lenses

    by Steven C. Schallhorn, Keith A. Hettinger, Stephen J. Od Hannan, Jan A. Venter, David Teenan, Julie M. Schallhorn

    Purpose: To assess the effect of residual sphere on vision and satisfaction in pseudophakic patients. Setting: Private clinics, United Kingdom. Design: Retrospective case series. Methods: A multivariate model evaluated the effect of 1-month residual sphere on outcomes of pseudophakic patients. Odds ratios (ORs) were calculated to assess the relative risk of not achieving ≥20/20 monocular uncorrected distance visual acuity (UDVA), ≥20/50 uncorrected near visual acuity (UNVA), and not being satisfied with vision. ORs were assessed for residual sphere −1.00 to +1.00 diopter (D) in quarter-diopter steps, using 0.00 D as a reference. Results: The analysis included 38 828 multifocal and 11 571 monofocal intraocular lenses (IOLs). The residual myopic sphere ≤−0.25 D and hyperopic sphere ≥+0.50 D had a clinically meaningful effect on UDVA. Although monofocal IOLs had an improvement in UNVA with every additional 0.25 D of myopia, the change in ORs with increasing myopia was not significant for multifocal IOLs. The mean improvement in UNVA comparing eyes with 0.00 D and −1.00 D sphere was 0.26 logMAR for monofocal and 0.03 logMAR for multifocal IOLs. Low near-addition IOLs had a slightly higher gain in UNVA with increasing myopia, but the gain was not as substantial as with monofocal IOLs. The effect of ametropia on satisfaction was more pronounced for multifocal IOLs. For every 0.25 D of residual myopia, there was >25% increase in dissatisfied patients. Conclusions: Although myopia improved UNVA in eyes with monofocal IOL, multifocal IOLs did not benefit from residual myopia. Multifocal IOL patients desiring distance vision should be targeted closest to emmetropia, even if it means targeting slight hyperopia.


  • Open Access

    Outcomes of a Refractive Segmented Bifocal Intraocular Lens with a Lower Near Addition

    by Jan A Venter, Barrie M Collins, Stephen J Hannan, David Teenan, Julie M Schallhorn

    Purpose: To evaluate clinical and subjective outcomes of a segmented bifocal IOL with a 2.0 D near addition. Patients and Methods: Retrospective analyses of patients who had undergone refractive lens exchange with bilateral implantation of the SBL-2 IOL (Lenstec, Inc., Christ Church, Barbados) were performed. The number of patients included in the study was 389 (778 eyes). Refractive, visual and patient-reported outcomes were presented for the last available visit (mean follow-up 2.05 ± 1.33 months). Results: The percentage of eyes within ± 0.50D and ± 1.00D of emmetropia was 82.5% (642/778) and 97.8% (761/778), respectively. The mean uncorrected intermediate visual acuity (66 cm) of the last available visit was 0.08 ± 0.15 logMAR monocularly and 0.04 ± 0.14 logMAR binocularly. The mean monocular and binocular uncorrected near visual acuity (40 cm) were 0.30 ± 0.15 logMAR and 0.24 ± 0.14 logMAR, respectively. Of all patients, 97.2% (378/389) claimed never to use any correction for distance vision, while 93.1% (362/389) of patients did not require any correction for near vision. The mean scores for visual phenomena (on the scale from 1 – no difficulty to 7 – severe difficulty) were 1.8 ± 1.3, 1.7 ± 1.2, 1.7 ± 1.2 and 1.6 ± 1.2 for glare, halo, starburst, and ghosting/double vision, respectively. Conclusion: Despite the lower near addition of SBL-2 segmented bifocal IOL, patients achieved reasonable rates of spectacle independence and a low incidence of visual phenomena.


  • Visual acuity improvement in adult amblyopic eyes with an iris-fixated phakic intraocular lens: Long-term results

    by Jan A. Venter, Martina Pelouskova, Steven C. Schallhorn, Barrie M. Collins

    Purpose To evaluate the effect of implantation of iris-fixated phakic intraocular lenses (pIOLs) (Artisan) in adult amblyopic eyes. Setting Optical Express, London, United Kingdom. Design Retrospective case series. Methods The study analyzed data from 5 years of follow-up of amblyopic eyes that were implanted with iris-fixated pIOLs and had a preoperative corrected distance visual acuity (CDVA) of 6/15 or worse. Visual acuity, refraction, endothelial cell count, and complications were assessed. Results Data for 103 eyes were analyzed as 2 groups. Group 1 comprised 82 eyes with myopia or myopic astigmatism, and Group 2 contained 21 eyes with hyperopia or hyperopic astigmatism. The mean preoperative sphere in Group 1 was −13.42 diopters (D) ± 5.62 (SD) with a mean cylinder of −2.35 ± 1.75 D. In Group 2, the mean sphere and cylinder were +6.77 ± 1.91 D and −2.63 ± 2.43 D, respectively. The mean CDVA improved from 0.51 ± 0.15 logMAR to 0.34 ± 0.16 logMAR (P<.001) in Group 1 and from 0.54 ± 0.17 logMAR to 0.46 ± 0.14 logMAR in Group 2 (P<.005). The safety index was 1.48 in Group 1 and 1.19 in Group 2. The efficacy index was 1.21 in Group 1 and 1.00 in Group 2. The mean gain in CDVA was statistically significantly greater in Group 1 (0.17 ± 0.14 logMAR) than in Group 2 (0.08 ± 0.11 logMAR). Two or more lines of CDVA were gained by 48.8% of eyes in Group 1 and by 19.0% of eyes in Group 2. Conclusion The iris-fixated pIOL was a safe and effective option for improving visual acuity in adult amblyopic eyes. Financial Disclosure Dr. Schallhorn is a consultant to Abbott Medical Optics, Inc. No other author has a financial or proprietary interest in any material or method mentioned.


  • Visual outcomes and patient satisfaction with a rotational asymmetric refractive intraocular lens for emmetropic presbyopia

    by Jan A. Venter, Martina Pelouskova, Claire E.L. Bull, Steven C. Schallhorn, Stephen J. Hannan

    To evaluate the efficacy, safety, predictability, and patient satisfaction after refractive lens exchange with a zonal refractive intraocular lens (IOL) with an inferior reading addition in emmetropic patients. Optical Express, London, United Kingdom. Retrospective case series. Emmetropic presbyopic patients who had implantation of a Lentis Mplus LS-313 MF30 IOL were evaluated. Inclusion criteria were sphere between -0.50 diopter (D) and +1.00 D with no more than 0.75 D of refractive cylinder and an uncorrected distance visual acuity (UDVA) of 6/6 or better in each eye. The main outcome measures were monocular and binocular UDVA, uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), and patient satisfaction. Three months data are presented. Four hundred forty eyes of 220 patients were evaluated. The mean monocular UDVA changed from -0.04 logMAR ± 0.06 (SD) preoperatively to -0.04 ± 0.11 logMAR postoperatively (P = .39). The mean CDVA was -0.10 ± 0.05 logMAR preoperatively and -0.09 ± 0.06 logMAR postoperatively (P = .06). At 3 months, 99.7% of eyes were within ±1.00 D of emmetropia. The mean UNVA was 0.13 ± 0.14 logMAR monocularly and 0.10 ± 0.12 logMAR binocularly. On the patient satisfaction questionnaire, 91.9% of patients said the refractive procedure improved their lives and 93.5% were willing to recommend it to friends and family. Three patients requested IOL exchange because of severe night-vision phenomena or unsatisfactory quality of vision. Refractive lens exchange with this zonal refractive IOL was safe in emmetropic presbyopic patients. Dr. Schallhorn is a consultant to Abbott Medical Optics. No other author has a financial or proprietary interest in any material or method mentioned.


  • Initial Experience With a New Refractive Rotationally Asymmetric Multifocal Intraocular Lens

    by Jan A. Venter, Dean Barclay, Martina Pelouskova, Claire E. L. Bull

    PURPOSE: To assess efficacy, safety, predictability, and patient satisfaction after refractive lens exchange with a new refractive rotational asymmetric multifocal intraocular lens. METHODS: One hundred six eyes of 53 patients after bilateral refractive lens exchange with the SBL-3 lens (Lenstec, Inc., Christ Church, Barbados) implantation were evaluated. The mean preoperative refractive sphere was +1.06 ± 2.63 diopters (D) (range: −8.25 to +5.00 D) and the mean refractive cylinder was −0.51 ± 0.46 D (range: −2.00 to 0.00 D). Monocular and binocular uncorrected and corrected distance visual acuity, uncorrected and distance-corrected intermediate visual acuity, uncorrected and distance-corrected near visual acuity, defocus curve, and patient satisfaction were evaluated 3 months postoperatively. RESULTS: At 3 months, 84.9% (90 eyes) were within ±0.50 D of emmetropia. The mean postoperative uncorrected distance visual acuity was −0.03 ± 0.09 logMAR (6/6 Snellen) monocularly and −0.08 ± 0.08 logMAR (6/4.8 Snellen) binocularly. The mean monocular and binocular uncorrected near visual acuity were 0.12 ± 0.12 and 0.08 ± 0.10 logMAR (6/7.5 Snellen), respectively. Defocus curve showed a slight drop off for vergences equivalent to intermediate vision. Although some night vision phenomena were reported, overall satisfaction was high. No intraoperative or postoperative complications occurred in this study. CONCLUSIONS: The new refractive rotationally asymmetric intraocular lens provided good range of vision for near, intermediate, and distance. Long-term follow-ups are necessary to evaluate the performance of this intraocular lens. [ J Refract Surg . 2014;30(11):770–776.]


  • Piggyback Intraocular Lens Implantation to Correct Pseudophakic Refractive Error After Segmental Multifocal Intraocular Lens Implantation

    by Jan A. Venter, Andre Oberholster, Steven C. Schallhorn, Martina Pelouskova

    PURPOSE: To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS: Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. RESULTS: The mean spherical equivalent ranged from −1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to −1.25 to +0.50 D (mean: −0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. CONCLUSIONS: Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. [ J Refract Surg. 2014;30(4):234–239.]