A Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps
Authors:
Open Access
- 29 May 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 71472-71480
Abstract
The discharge characteristics of long air gaps are of great significance in the external insulation design of extra high voltage (EHV) and ultra high voltage (UHV) transmission lines. At present, the breakdown characteristics of air gaps are mainly investigated by repeated full-scale discharge tests. In order to reduce the costly experiment works, the influence of different tower structures on air gap breakdown voltage have been fully studied, and the tower structure coefficient Tg is proposed and calculated. Then a modified mathematical model is developed to calculate the 50 % discharge voltage of complicated bundle conductor-tower air gaps. The research results show that the 50% discharge voltages of different tower structures calculated by this models are in good agreement with the on-site test results. The maximum errors between the calculated and the test data is less than 6.3 %, which proves the feasibility of the proposed model for various engineering air gaps.Keywords
This publication has 16 references indexed in Scilit:
- Application of dynamic models to predict switching impulse withstand voltages of long air gapsIEEE Transactions on Dielectrics and Electrical Insulation, 2013
- A Simplified Physical Model to Determine the Lightning Upward Connecting Leader InceptionIEEE Transactions on Power Delivery, 2006
- Fundamental processes in long air gap dischargesComptes Rendus. Physique, 2002
- Theoretical analysis of the processes involved in lightning attachment to earthed structuresJournal of Physics D: Applied Physics, 2002
- Assessment of protection system positioning and models using observations of lightning strikes to structuresProceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2002
- Critical switching impulse breakdown of long bundle-conductor gapsIEEE Transactions on Power Delivery, 1996
- A model for switching impulse leader inception and breakdown of long air-gapsIEEE Transactions on Power Delivery, 1989
- Switching impulse strength of air insulation: leader inception criterionIEEE Transactions on Power Delivery, 1989
- Switching surge strength of large air gaps: A physical approachIEEE Transactions on Power Apparatus and Systems, 1976
- Influence of Air Gap Characteristics on Line-to-Ground Switching Surge StrengthIEEE Transactions on Power Apparatus and Systems, 1967