A Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps

Authors:

Abstract
The discharge characteristics of long air gaps are of great significance in the external insulation design of extra high voltage (EHV) and ultra high voltage (UHV) transmission lines. At present, the breakdown characteristics of air gaps are mainly investigated by repeated full-scale discharge tests. In order to reduce the costly experiment works, the influence of different tower structures on air gap breakdown voltage have been fully studied, and the tower structure coefficient Tg is proposed and calculated. Then a modified mathematical model is developed to calculate the 50 % discharge voltage of complicated bundle conductor-tower air gaps. The research results show that the 50% discharge voltages of different tower structures calculated by this models are in good agreement with the on-site test results. The maximum errors between the calculated and the test data is less than 6.3 %, which proves the feasibility of the proposed model for various engineering air gaps.

This publication has 16 references indexed in Scilit: