Yaqi Fang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yaqi Fang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Rui Li
State Grid Hubei Electric Power CO. LTD, Wuhan 430048, People’s Republic of China
5 shared publicationsBin Song
School of Electrical Engineering and Automation Wuhan University Wuhan People's Republic of China
4 shared publicationsLinong Wang
School of Electrical Engineering and Automation Wuhan University Wuhan People's Republic of China
4 shared publicationsHao Zeng
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology, Wuhan 430068, People’s Republic of China
2 shared publicationsJiachen Gao
School of Electrical Engineering and Automation Wuhan University Wuhan People's Republic of China
2 shared publicationsKai Liu
China Electric Power Research Institute Wuhan People's Republic of China
2 shared publications
Latest Publications
- Open Access
Study on Multi-Parameter Evolution Characteristics of 314 Ah High-Capacity LiFePO4 Batteries During Thermal Runaway Under Various Abuse Conditions
High-capacity energy storage batteries contain complex physicochemical systems. The thermal runaway within batteries pose significant challenges to widespread application in energy storage systems. To better investigate the safety warning thresholds of battery energy storage systems, it is necessary to study the thermal runaway characteristics and behavioral patterns of batteries under various abusive conditions. This study focuses primarily on energy storage batteries in actual operation and on simulating real-world operating conditions. A multi-parameter experimental monitoring platform based on temperature, voltage, expansion force, and particulate matter concentration was established to investigate the multi-parameter variation patterns and distinctive characteristics of thermal runaway in energy storage cells under electrothermal coupling and overcharging abuse conditions. The results show that under electrothermal coupling conditions, the initial critical moment of thermal runaway occurs 530 s earlier than under overcharging conditions, with a maximum temperature reaching 457.2 °C; however, under overcharging conditions, the thermal runaway process is more severe, with a maximum temperature reaching 580.9 °C. A comparative analysis of the early warning thresholds for multiple parameters revealed that the threshold based on mechanical signals appears the earliest. Under electrothermal coupling conditions, the force signal preceded the injection valve signal, voltage signal, and temperature signal by 121 s, 305 s, and 732 s, respectively, with a maximum expansion force of 6836 N; under electrical abuse conditions, the force signal preceded the aforementioned signals by 458 s, 711 s, and 1733 s, respectively, with a maximum expansion force reaching 7566 N. This study provides a basis for the thermal management design and safety control of energy storage batteries. This study offers insights for safeguarding the proper operation of battery energy storage systems.
Open AccessStudy on Multi-Parameter Evolution Characteristics of 314 Ah High-Capacity LiFePO4 Batteries During Thermal Runaway Under Various Abuse Conditions
High-capacity energy storage batteries contain complex physicochemical systems. The thermal runaway within batteries pose significant challenges to widespread application in energy storage systems. To better investigate the safety warning thresholds of battery energy storage systems, it is necessary to study the thermal runaway characteristics and behavioral patterns of batteries under various abusive conditions. This study focuses primarily on energy storage batteries in actual operation and on simulating real-world operating conditions. A multi-parameter experimental monitoring platform based on temperature, voltage, expansion force, and particulate matter concentration was established to investigate the multi-parameter variation patterns and distinctive characteristics of thermal runaway in energy storage cells under electrothermal coupling and overcharging abuse conditions. The results show that under electrothermal coupling conditions, the initial critical moment of thermal runaway occurs 530 s earlier than under overcharging conditions, with a maximum temperature reaching 457.2 °C; however, under overcharging conditions, the thermal runaway process is more severe, with a maximum temperature reaching 580.9 °C. A comparative analysis of the early warning thresholds for multiple parameters revealed that the threshold based on mechanical signals appears the earliest. Under electrothermal coupling conditions, the force signal preceded the injection valve signal, voltage signal, and temperature signal by 121 s, 305 s, and 732 s, respectively, with a maximum expansion force of 6836 N; under electrical abuse conditions, the force signal preceded the aforementioned signals by 458 s, 711 s, and 1733 s, respectively, with a maximum expansion force reaching 7566 N. This study provides a basis for the thermal management design and safety control of energy storage batteries. This study offers insights for safeguarding the proper operation of battery energy storage systems.
- 9 February 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (7)
Influence of high altitude on streamer discharge mechanism of sphere-plane gaps under positive switching impulse
China's energy resources and load centers are unevenly distributed, and many Extra-high voltage (EHV) and ultra-high voltage (UHV) projects pass through high-altitude regions, posing challenges for air-gap insulation. Understanding streamer behavior in high-altitude conditions aids in optimizing insulation design for power systems. This paper conducts positive switching impulse discharge experiments on sphere-plane gap with electrode radii of 0.15 to 0.45 m and a gap distance of 2 m at 2100 m altitude. The critical inception voltage, boost time delay, and statistical time delay are analyzed combining the photoionization model. The effects of electrode size and atmospheric pressure on statistical time delay are studied with the critical volume model. The evolution law of the discharge channel is explored from the perspective of microscopic particle reactions using a one-dimensional streamer-leader discharge model. The results show that critical inception voltage of streamer increases with electrode radius but decreases with lower air pressure. Both boost time delay and statistical time delay increase with larger electrode sizes. The combined effects of critical volume and internal field strength make the field strength's influence on statistical time delay more significant. The fact that E/P remains consistently higher under low-pressure conditions compared to standard atmospheric pressure indicates that negative ions have a shorter lifetime at low pressure, making it easier for free electrons to be released, thereby promoting earlier streamer inception at high altitudes. The micro particle number density during the development of streamer in high-altitude environments is lower than that at lower altitudes, and the discharge channel requires more time to absorb energy to maintain discharge development. These findings provide theoretical support for high-altitude discharge studies and are significant for insulation design and protection of high-voltage equipment.
- 9 February 2026
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 59 (7)
Influence of high altitude on streamer discharge mechanism of sphere-plane gaps under positive switching impulse
China's energy resources and load centers are unevenly distributed, and many Extra-high voltage (EHV) and ultra-high voltage (UHV) projects pass through high-altitude regions, posing challenges for air-gap insulation. Understanding streamer behavior in high-altitude conditions aids in optimizing insulation design for power systems. This paper conducts positive switching impulse discharge experiments on sphere-plane gap with electrode radii of 0.15 to 0.45 m and a gap distance of 2 m at 2100 m altitude. The critical inception voltage, boost time delay, and statistical time delay are analyzed combining the photoionization model. The effects of electrode size and atmospheric pressure on statistical time delay are studied with the critical volume model. The evolution law of the discharge channel is explored from the perspective of microscopic particle reactions using a one-dimensional streamer-leader discharge model. The results show that critical inception voltage of streamer increases with electrode radius but decreases with lower air pressure. Both boost time delay and statistical time delay increase with larger electrode sizes. The combined effects of critical volume and internal field strength make the field strength's influence on statistical time delay more significant. The fact that E/P remains consistently higher under low-pressure conditions compared to standard atmospheric pressure indicates that negative ions have a shorter lifetime at low pressure, making it easier for free electrons to be released, thereby promoting earlier streamer inception at high altitudes. The micro particle number density during the development of streamer in high-altitude environments is lower than that at lower altitudes, and the discharge channel requires more time to absorb energy to maintain discharge development. These findings provide theoretical support for high-altitude discharge studies and are significant for insulation design and protection of high-voltage equipment.
- Open Access
- 28 February 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (7) , 1271-1278
Modelling for switching impulse breakdown of live working gaps between equipotential worker and transmission towers
Air gap discharge voltage is the key parameter to determine the minimum approach distance for live working. In this study, a mathematical–physical model for predicting 50% discharge voltage of the transmission line air gaps considering the effect of live line worker is developed based on the continuous leader inception criterion. Also, the tower structure coefficient S T is proposed to represent the influence of various tower structures and S T is calculated by finite element method. Finally, the switching impulse discharge tests of the equipotential worker‐tower structure gaps are carried out on 750 kV transmission lines to verify the proposed model. The research results show that the errors between the calculation and experimental data are within ±4.03% which demonstrates the feasibility of discharge voltage prediction for complicated live working gaps. This model offers a possible way to determine the safety air gap distance for live working by analytical and numerical calculation rather than costly and time‐consuming experiments.
- 28 February 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (7) , 1271-1278
Open AccessModelling for switching impulse breakdown of live working gaps between equipotential worker and transmission towers
Air gap discharge voltage is the key parameter to determine the minimum approach distance for live working. In this study, a mathematical–physical model for predicting 50% discharge voltage of the transmission line air gaps considering the effect of live line worker is developed based on the continuous leader inception criterion. Also, the tower structure coefficient S T is proposed to represent the influence of various tower structures and S T is calculated by finite element method. Finally, the switching impulse discharge tests of the equipotential worker‐tower structure gaps are carried out on 750 kV transmission lines to verify the proposed model. The research results show that the errors between the calculation and experimental data are within ±4.03% which demonstrates the feasibility of discharge voltage prediction for complicated live working gaps. This model offers a possible way to determine the safety air gap distance for live working by analytical and numerical calculation rather than costly and time‐consuming experiments.
- Open Access
- 29 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 71472-71480
A Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps
The discharge characteristics of long air gaps are of great significance in the external insulation design of extra high voltage (EHV) and ultra high voltage (UHV) transmission lines. At present, the breakdown characteristics of air gaps are mainly investigated by repeated full-scale discharge tests. In order to reduce the costly experiment works, the influence of different tower structures on air gap breakdown voltage have been fully studied, and the tower structure coefficient Tg is proposed and calculated. Then a modified mathematical model is developed to calculate the 50 % discharge voltage of complicated bundle conductor-tower air gaps. The research results show that the 50% discharge voltages of different tower structures calculated by this models are in good agreement with the on-site test results. The maximum errors between the calculated and the test data is less than 6.3 %, which proves the feasibility of the proposed model for various engineering air gaps.
- 29 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 71472-71480
Open AccessA Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps
The discharge characteristics of long air gaps are of great significance in the external insulation design of extra high voltage (EHV) and ultra high voltage (UHV) transmission lines. At present, the breakdown characteristics of air gaps are mainly investigated by repeated full-scale discharge tests. In order to reduce the costly experiment works, the influence of different tower structures on air gap breakdown voltage have been fully studied, and the tower structure coefficient Tg is proposed and calculated. Then a modified mathematical model is developed to calculate the 50 % discharge voltage of complicated bundle conductor-tower air gaps. The research results show that the 50% discharge voltages of different tower structures calculated by this models are in good agreement with the on-site test results. The maximum errors between the calculated and the test data is less than 6.3 %, which proves the feasibility of the proposed model for various engineering air gaps.
- Open Access
- 4 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 6758-6764
AC Flashover Performance of FRP Hot Stick for Live Working in High Altitude Areas
- 4 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 6758-6764
Open AccessAC Flashover Performance of FRP Hot Stick for Live Working in High Altitude Areas
- Open Access
- 19 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2444-2448
Research of active load regulation method for distribution network considering distributed photovoltaic and electric vehicles
In order to solve the problem of three‐phase unbalance in low‐voltage distribution network caused by large‐scale access of distributed photovoltaic (PV) and electric vehicles (EVs), an active load control method of three‐phase unbalance in distribution network was presented in this study. Firstly, the active load regulation system was established and its implementation scheme was detailed. Then the active load regulation strategy using an integrated multi‐objective optimisation control algorithm was put forward and a solution method based on improved genetic algorithm was also proposed to realise optimal load distribution. Finally, the validity and feasibility of the proposed strategy was verified by simulation and the simulation results show that the active load regulation strategy can improve the consumptive ability of distributed PV and EVs, and can effectively reduce the three‐phase unbalance degree to improve the quality of power supply.
- 19 January 2017
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2444-2448
Open AccessResearch of active load regulation method for distribution network considering distributed photovoltaic and electric vehicles
In order to solve the problem of three‐phase unbalance in low‐voltage distribution network caused by large‐scale access of distributed photovoltaic (PV) and electric vehicles (EVs), an active load control method of three‐phase unbalance in distribution network was presented in this study. Firstly, the active load regulation system was established and its implementation scheme was detailed. Then the active load regulation strategy using an integrated multi‐objective optimisation control algorithm was put forward and a solution method based on improved genetic algorithm was also proposed to realise optimal load distribution. Finally, the validity and feasibility of the proposed strategy was verified by simulation and the simulation results show that the active load regulation strategy can improve the consumptive ability of distributed PV and EVs, and can effectively reduce the three‐phase unbalance degree to improve the quality of power supply.