Clinical Tolerance to Experimentally Induced with-the-Rule and Against-the-Rule Astigmatism After Implantation of an Extended Depth-of-Focus Intraocular Lens: A Defocus-Curve Study
Open Access
- 1 December 2025
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 4967-4974
Abstract
Purpose: To quantify the clinical tolerance to induced with-the-rule (WTR, 90°) and against-the-rule (ATR, 0°/180°) astigmatism after implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL), and to identify axis-specific trade-offs across the defocus curve. Methods: In this non-randomized, comparative, cross-sectional study, nine pseudophakic patients (nine dominant eyes) implanted with a Tecnis Symfony® EDOF IOL underwent monocular photopic testing (85 cd/m2) at 4 m using Early Treatment Diabetic Retinopathy Study (ETDRS) charts. Defocus curves were acquired from − 5.00 D to +2.50 D in 0.50-D steps over best subjective refraction. Regular myopic astigmatism was optically induced with +1.00 D, +2.00 D, and +3.00 D positive cylindrical lenses at canonical axes (0°, 45°, 90°, 135°); analyses focused on WTR (90°) and ATR (0°/180°). Visual acuity (VA) was converted to logMAR. Repeated-measures ANOVA with Tukey post hoc testing assessed effects of cylinder magnitude, axis, and vergence (α=0.05). Results: Distance VA remained functionally preserved with +1.00 D, while +2.00 D produced clinically meaningful deterioration and +3.00 D caused broad loss of acuity across vergences. Axis orientation modulated performance: WTR preserved distance acuity around plano, whereas ATR relatively favored intermediate and very near vergences (approximately − 2.00 D to − 3.50 D). ANOVA confirmed significant effects of cylinder magnitude and vergence (both p< 0.01) and a significant axis-by-vergence interaction near plano and +0.50 D (p< 0.05). These findings support a practical tolerance envelope of about +1.00 D for EDOF recipients, beyond which functional penalties become evident. Conclusion: After EDOF implantation, regular astigmatism of ~+1.00 D is generally tolerated, while +2.00 D and +3.00 D compromise function across the defocus curve. Axis matters: WTR preferentially preserves distance VA and ATR relatively supports intermediate/near performance. These data provide actionable thresholds and axis-aware guidance for toric planning, residual-targeting, and patient counseling.Keywords
This publication has 25 references indexed in Scilit:
- Tolerance to residual astigmatism of an isofocal intraocular lensGraefe's Archive for Clinical and Experimental Ophthalmology, 2023
- Extended Depth of Focus Versus Trifocal for Intraocular Lens Implantation: An Updated Systematic Review and Meta-AnalysisAmerican Journal of Ophthalmology, 2023
- Effect of Refractive Astigmatism on All-Distance Visual Acuity in Eyes With a Trifocal Intraocular LensAmerican Journal of Ophthalmology, 2021
- Surgical correction of presbyopiaJournal of Cataract & Refractive Surgery, 2016
- Minimum amount of astigmatism that should be correctedJournal of Cataract & Refractive Surgery, 2014
- Toric intraocular lenses: Historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complicationsJournal of Cataract & Refractive Surgery, 2013
- Dissatisfaction after implantation of multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2011
- Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2010
- Dissatisfaction after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2009
- Prevalence of corneal astigmatism before cataract surgeryJournal of Cataract & Refractive Surgery, 2009