MCMario Augusto Pereira Dias Chaves

Mario Augusto Pereira Dias Chaves

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mario Augusto Pereira Dias Chaves has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Kit de triagem oftalmológica na Atenção Primária como ferramenta de prevenção da cegueira e baixa visão infantil

    by Michelle Rodrigues Gonçalves Dias Chaves, Gabriel Rodrigues, Mario Augusto Pereira Dias Chaves, Maria da Conceição Rodrigues Gonçalves, Isabella Wanderley de Queiroga Evangelista, Vagna Cristina Leite da Silva Pereira

    RESUMO Objetivo: Desenvolver e descrever o kit oftalmológico de triagem para uso por médicos generalistas na Atenção Primária à Saúde, visando à triagem de crianças de zero a 10 anos e à prevenção da ambliopia. Métodos: Estudo metodológico em quatro fases: revisão integrativa da literatura; planejamento com matriz SWOT; construção dos componentes do kit oftalmológico de triagem; e refinamento com avaliação de funcionalidade, validade de conteúdo, aplicabilidade e limitações. Resultados: O kit oftalmológico de triagem reuniu: manual de orientação médica [...] RESUMO Objetivo: Desenvolver e descrever o kit oftalmológico de triagem para uso por médicos generalistas na Atenção Primária à Saúde, visando à triagem de crianças de zero a 10 anos e à prevenção da ambliopia. Métodos: Estudo metodológico em quatro fases: revisão integrativa da literatura; planejamento com matriz SWOT; construção dos componentes do kit oftalmológico de triagem; e refinamento com avaliação de funcionalidade, validade de conteúdo, aplicabilidade e limitações. Resultados: O kit oftalmológico de triagem reuniu: manual de orientação médica

  • Open Access

    Visual Field Stability After Trifocal Intraocular Lens Implantation: A Longitudinal Standard Automated Perimetry Study

    by Wilson Takashi Hida, Maira Gomes Barbosa Da Silva, Bernardo Kaplan Moscovici, César Vilar, Paulo Tadeu Silva Campos, Larissa Gouvea, Michael Chow, Patrick Frensel de Moraes Tzelikis, Mario Augusto Pereira Dias Chaves, Antonio Francisco Pimenta Motta, et al.

    Purpose: To investigate whether implantation of a diffractive trifocal intraocular lens (IOL) is followed by systematic changes in standard automated perimetry (SAP) global indices and test reliability in a paired pre–post design. Methods: Patients who underwent uncomplicated cataract surgery with PanOptix trifocal IOL implantation and completed SAP before and after surgery under the same institutional protocol were analyzed. Baseline SAP was obtained within 6 months preoperatively, and follow-up SAP was obtained within 12 months postoperatively. Unreliable examinations were excluded, and right and left eyes were analyzed separately. Outcomes included mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), foveal threshold, and reliability indices. Pre- and postoperative values were compared using paired tests. Results: Reliability remained comparable to baseline. False-positive rates were 1.7% ± 2.6% preoperatively versus 1.6% ± 1.6% postoperatively in right eyes (p = 0.88) and 1.5% ± 2.1% versus 1.3% ± 1.9% in left eyes (p = 0.73). False-negative rates were 0.9% ± 1.5% versus 1.7% ± 2.1% in right eyes (p = 0.24) and 1.5% ± 2.2% versus 1.9% ± 2.5% in left eyes (p = 0.62). Global indices showed no significant pre–post differences: MD was − 1.3 ± 1.2 dB versus − 1.2 ± 0.9 dB in right eyes (p = 0.54) and − 1.7 ± 1.6 dB versus − 1.5 ± 1.6 dB in left eyes (p = 0.65). VFI was 99.0% ± 0.4% versus 98.9% ± 0.9% in right eyes (p = 0.77) and 98.2% ± 0.8% versus 97.8% ± 1.8% in left eyes (p = 0.45). PSD was unchanged (right p = 0.34; left p = 0.08). Foveal threshold decreased slightly in right eyes (35.9 ± 1.3 to 35.0 ± 1.1 dB, p = 0.06). Conclusion: Trifocal IOL implantation was not associated with clinically meaningful deterioration in SAP global indices or reliability measures during follow-up.


  • Open Access

    Standard Automated Perimetry Before and After Extended Depth-of-Focus Intraocular Lens Implantation: Longitudinal Changes in Global Indices and Test Reliability

    by Wilson Hida, Maira da Silva, Bernardo Moscovici, César Vilar, Paulo Campos, Larissa Gouvea, Michael Chow, Patrick Tzelikis, Mario Augusto Chaves, Antonio Motta, et al.

    To describe changes in standard automated perimetry (SAP) parameters before and after extended depth-of-focus (EDOF) intraocular lens implantation (Symfony) in a longitudinal before–and–after design. Patients undergoing cataract surgery with EDOF IOL implantation were evaluated with SAP preoperatively (baseline) and postoperatively (6–12 months after surgery). Thirteen patients (23 eyes) completed both examinations. The right and left eyes were analyzed separately. Outcomes included foveal threshold, mean deviation (MD), pattern standard deviation (PSD), visual field index (VFI), and reliability indices (false-positive and false-negative rates). Data were summarized as mean ± standard deviation (SD) and compared between time points using paired tests. SAP was performed with the Humphrey Field Analyzer II using the SITA Standard 24–2 strategy. SAP outcomes showed small, non-significant changes from baseline to follow-up. MD improved slightly (right: −1.1 ± 1.2 to −0.8 ± 1.2 dB, p = 0.32; left: −1.9 ± 0.9 to −1.2 ± 1.1 dB, p = 0.12). VFI remained stable (right: 99.1% ± 1.1% to 98.8% ± 1.4%, p = 0.43; left: 98.0% ± 1.1% to 98.0% ± 2.1%, p = 1.00). Foveal threshold was unchanged (right: 35.1 ± 1.9 to 35.2 ± 0.9 dB, p = 0.86; left: 34.0 ± 1.0 to 34.5 ± 1.3 dB, p = 0.26). PSD showed no significant variation (right: 1.9 ± 0.9 to 1.7 ± 0.4 dB, p = 0.34; left: 1.8 ± 0.3 to 1.9 ± 1.2 dB, p = 0.73). Reliability indices were also stable: false positives (right: 1.9% ± 2.6% to 2.1% ± 1.4%, p = 0.75; left: 1.4% ± 2.5% to 0.5% ± 0.6%, p = 0.21) and false negatives (right: 1.6% ± 2.1% to 1.7% ± 3.1%, p = 0.91; left: 2.2% ± 2.9% to 1.1% ± 1.5%, p = 0.35). In this longitudinal before–and–after evaluation, EDOF IOL implantation was not associated with clinically meaningful changes in SAP outcomes, with stable global indices, foveal threshold, and reliability measures.


  • Open Access

    Clinical Tolerance to Experimentally Induced with-the-Rule and Against-the-Rule Astigmatism After Implantation of an Extended Depth-of-Focus Intraocular Lens: A Defocus-Curve Study

    by Wilson Takashi Hida, Leandro Pessoa Mundim, Bernardo Kaplan Moscovici, César Martins Cortez Vilar, Patrick Frensel De Moraes Tzelikis, Celso Takashi Nakano, Irineu Ribeiro de Melo Junior, André Lins de Medeiros, Jonathan Clive Lake, Mario Augusto Pereira Dias Chaves, et al.

    Purpose: To quantify the clinical tolerance to induced with-the-rule (WTR, 90°) and against-the-rule (ATR, 0°/180°) astigmatism after implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL), and to identify axis-specific trade-offs across the defocus curve. Methods: In this non-randomized, comparative, cross-sectional study, nine pseudophakic patients (nine dominant eyes) implanted with a Tecnis Symfony® EDOF IOL underwent monocular photopic testing (85 cd/m2) at 4 m using Early Treatment Diabetic Retinopathy Study (ETDRS) charts. Defocus curves were acquired from − 5.00 D to +2.50 D in 0.50-D steps over best subjective refraction. Regular myopic astigmatism was optically induced with +1.00 D, +2.00 D, and +3.00 D positive cylindrical lenses at canonical axes (0°, 45°, 90°, 135°); analyses focused on WTR (90°) and ATR (0°/180°). Visual acuity (VA) was converted to logMAR. Repeated-measures ANOVA with Tukey post hoc testing assessed effects of cylinder magnitude, axis, and vergence (α=0.05). Results: Distance VA remained functionally preserved with +1.00 D, while +2.00 D produced clinically meaningful deterioration and +3.00 D caused broad loss of acuity across vergences. Axis orientation modulated performance: WTR preserved distance acuity around plano, whereas ATR relatively favored intermediate and very near vergences (approximately − 2.00 D to − 3.50 D). ANOVA confirmed significant effects of cylinder magnitude and vergence (both p< 0.01) and a significant axis-by-vergence interaction near plano and +0.50 D (p< 0.05). These findings support a practical tolerance envelope of about +1.00 D for EDOF recipients, beyond which functional penalties become evident. Conclusion: After EDOF implantation, regular astigmatism of ~+1.00 D is generally tolerated, while +2.00 D and +3.00 D compromise function across the defocus curve. Axis matters: WTR preferentially preserves distance VA and ATR relatively supports intermediate/near performance. These data provide actionable thresholds and axis-aware guidance for toric planning, residual-targeting, and patient counseling.


  • Open Access

    Objective and subjective visual outcome comparison analysis of two diffractive presbyopic correcting intraocular lenses

    by Maria Carolina Zanata, César Vilar, Bernardo Kaplan Moscovici, Mario Augusto Pereira Dias Chaves, Patrick Frensel de Moraes Tzelikis, Jonathan Clive Lake, Paulo Tadeu Silva Campos, Maurício Agne Newald, André Lins de Medeiros, Antônio Francisco Pimenta Motta, et al.

    This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus [...] ABSTRACT This case series evaluates the visual outcomes of two trifocal intraocular lenses, the ZFR00V and TNFT00, in cataract surgery patients. Nineteen patients (38 eyes) were bilaterally implanted with one of the two intraocular lenses. Postoperative assessments included uncorrected and corrected distance, intermediate, and near visual acuities, as well as patient-reported satisfaction and photic phenomena. Both intraocular lenses provided satisfactory visual performance for distance and intermediate vision. However, the ZFR00V intraocular lenses demonstrated superior near vision, particularly in the defocus


  • Open Access

    Comparison of Self-Test Refraction, Autorefraction, and Subjective Refraction

    by Abraão Ferreira de Sousa Neto Kós, Bernardo Kaplan Moscovici, Cesar Vilar, Mario Augusto Pereira Dias Chaves, Maíra Gomes Barbosa Da Silva, Maurício Agne Neuwald, André Lins De Medeiros, Jonathan Clive Lake, Antonio Francisco Pimenta Motta, Patrick Frensel de Moraes Tzelikis, et al.

    Purpose: To compare the performance of a self-refraction device (EyeQue Vision Check 2, EyeQue, USA) with autorefraction (OPD-Scan III, NIDEK) and subjective cycloplegic refraction in measuring refractive errors. Methods: This descriptive study included 80 eyes from 40 patients. Measurements were obtained using the portable EyeQue device, OPD-Scan III, and subjective cycloplegic refraction performed by an experienced examiner. Spherical equivalent (SE), cylindrical power, and axis values were analyzed using power vector decomposition (M, J0, J45) to improve accuracy in comparing methods. The main outcome was the agreement between self-refraction, autorefraction, and subjective refraction. Results: The EyeQue device showed lower variability and greater homogeneity in spherical measurements but exhibited lower precision for cylindrical power and axis than subjective refraction. Power vector analysis revealed that EyeQue overestimated spherical equivalent (M) and produced higher J0 values, suggesting a tendency to alter cylindrical correction. Although comparable to OPD-Scan in spherical refraction, EyeQue demonstrated inconsistencies in astigmatism correction, particularly in J45 components. Conclusion: The EyeQue device is a promising tool for large-scale screenings due to its affordability and portability. However, its limitations in astigmatism and axis measurements indicate that subjective refraction should complement rather than replace it. Therefore, further refinement and validation in diverse populations are recommended.


  • Open Access

    Validation of Clinical Protocol of Astigmatism Induction in Pseudophakic Patients

    by Irineu De Melo, Wilson Takashi Hida, Bernardo Kaplan Moscovici, Cesar Vilar, Antonio Francisco Pimenta Motta, Andre Lins de Medeiros, Mario Augusto Pereira Dias Chaves, Jonathan Clive Lake, Walton Nose, Pedro Carlos Carricondo

    Purpose: Validate a novel approach for assessing residual astigmatism’s impact on visual acuity in pseudophakic patients using defocus curves and spherical equivalent compensation. Materials and Methods: Thirteen patients over 40 with cataracts and normal ophthalmological examinations were enrolled in a prospective, non-randomized cohort study. The defocus curve method was employed, wherein visual acuity was measured with spherical lenses ranging from − 2.50 to +2.50 diopters in 0.5 diopter increments based on subjective refraction. Cylindrical lenses (+1, +2, and +3 diopters) were introduced at each spherical diopter’s 90° and 180° axes. Curves’ results were compared at each defocus point to assess the impact of astigmatism. The Kruskal–Wallis test was used to determine if astigmatism significantly affected visual acuity post-phacoemulsification surgery with intraocular lens implantation. Results: Significant p-values were observed only for defocus curve points of − 0.5, 0, +0.5, and +1, indicating rejection of the hypothesis of no difference between the 90° and 180° groups at these points. Although statistical significance was not achieved, the against-the-rule (ATR) group was inclined toward improved near and intermediate visual acuity. In contrast, the with-the-rule (WTR) group tended to enhance distance visual acuity and myopic tolerance. Conclusion: This novel methodology is both reproducible and valuable. It offers potential insight into residual astigmatism tolerance in pseudophakic patients. Its application may aid in surgical planning and intraocular lens decision-making.


  • Open Access

    Architecture evaluation of the main clear corneal incisions in femtosecond laser-assisted cataract surgery by optical coherence tomography imaging

    by Mario Augusto Pereira Dias Chaves, André Lins de Medeiros, César Martins Cortez Vilar, Klayne Rafaella Pereira Magalhães, Michelle Rodrigues Gonçalves, Patrick Frenzel de Moraes Tzelikis, Wilson Takashi Hida, Pedro Carlos Carricondo, Milton Ruiz Alves

    Purpose: To assess the stability and reliability of femtosecond laser-assisted cataract surgery (FLACS) incisions design and dimensions using anterior segment optical coherence tomography (AS-OCT) imaging. Setting: Renato Ambrósio Ophthalmologic Study Center from Hospital Oftalmológico de Brasília, Brasília, Brazil. Design: Prospective nonrandomized controlled case series. Methods: Eyes undergoing FLACS with triplanar main temporal clear corneal incision (CCI) were evaluated at the end of the case. Eyes that required any incision hydration, surgical complications or lacked follow-up were excluded. The AS-OCT was performed after femtosecond delivery; at the end of the case; at 1 day and at 30 days after surgery. Data of pachymetry, endothelial and epithelial gaps, Descemet detachment and CCI architecture were compared. Results: Eleven eyes from 11 patients completed follow-up. Corneal thickness was statistically different between after femtosecond delivery and the end of the case (P-value P-value P-value =0.0133) at the end of the case compared to post-femtosecond delivery. As for the architecture of the CCI, significant difference was found between the parameters of entry angle and exit angle measured with AS-OCT and the programmed. Conclusion: The AS-OCT was capable of visualizing changes in the cornea at the CCI. Despite the stress caused by manipulation, results indicated good stability of incision and reproducibility of tunnel length. Synopsis: Difference of corneal thickness at the CCI between after femtosecond and after phacoemulsification measurements (P-value P-value =0.0133) and Descemet detachments (P-value <0.05).


  • Open Access

    Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine

    by Wilson Takashi Hida, André Lins de Medeiros, André Gustavo de Araújo Rolim, Antonio Francisco Pimenta Motta, Danilo Varela Kniggendorf, Rodrigo Lafetá Franco de Queiroz, Mário Augusto Pereira Dias Chaves, Pedro Carlos Carricondo, Celso Takashi Nakano, Walton Nosé

    Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signaturereg phacoemulsification machine Wilson Takashi Hida,1–3 André Lins de Medeiros,1,2 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,3 Danilo Varela Kniggendorf,1,2 Rodrigo Lafetá Franco de Queiroz,1,2 Mário Augusto Pereira Dias Chaves,1,2 Pedro Carlos Carricondo,1,2 Celso Takashi Nakano,2,4 Walton Nosé5 1Cataract Sector, Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil; 2Cataract Sector, Centro de Estudos Oftalmológicos Renato Ambrósio, Brasília, Brazil; 3Cataract Sector, Universidade de São Paulo, São Paulo, Brazil; 4Cataract Sector, Hospital Santa Cruz, São Paulo, Brazil; 5Cataract Sector, Universidade Federal de São Paulo, São Paulo, Brazil Purpose: To compare intraoperative parameters between venturi and peristaltic pump in WhiteStar Signature® phacoemulsification machine using the bevel-down technique.Setting: Hospital Oftalmológico de Brasília, Brasília, Federal District, Brazil.Design: Prospective, comparative, patient-masked study.Methods: Three hundred eyes were randomly assigned to have a phacoemulsification procedure with WhiteStar Signature® using either peristaltic (n=150 eyes) or venturi (n=150 eyes) pumps by a single surgeon (WTH). Elliptical ultrasound setting and prefracture (prechop or preslice) techniques were used in all cases. Cataract nucleus density was graded using lens opacities classification system III and Pentacam Nucleus Staging classification. Clinical measurements included preoperative- and postoperative- corrected visual acuity, preoperative and 2-month postoperative endothelial cell counts, and preoperative and 1-day postoperative central corneal thickness. Intraoperative measurements at the end of the case were phaco time, fluid used, total case time, and Efx energy.Results: There were no statistically significant differences between groups regarding age, cataract density, and phaco time (P>0.05). Intraoperatively, we observed significantly less ultrasound energy (P=0.011), case time (P=0.0001), and balanced saline solution (P=0.001) usage in the venturi group. Clinically, both fluidic settings can provide similar clinical outcomes and visual recovery, regarding corrected distance visual acuity, endothelial cell count, and central corneal thickness.Conclusion: Our data show that to minimize fluid use, case time, and energy with the prefracture technique, the venturi pump was the most efficient system and was statistically superior to peristaltic pump. Keywords: venturi, peristaltic, phacoemulsification, cataract surgery, vacuum efficiency


  • Open Access

    Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens

    by Andre Lins de Medeiros, Andre Gustavo de Araujo Rolim, Antonio Francisco Pimenta Motta, Bruna Vieira Ventura, César Vilar, Mario Augusto Pereira Dias Chaves, Pedro Carlos Carricondo, Wilson Takashi Hida

    Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens André Lins de Medeiros,1–4 André Gustavo de Araújo Rolim,1,2 Antonio Francisco Pimenta Motta,2,5 Bruna Vieira Ventura,3,6 César Vilar,1,2,7 Mário Augusto Pereira Dias Chaves,1–3,8 Pedro Carlos Carricondo,2,5 Wilson Takashi Hida1,2,5 1Cataract Department, Hospital Oftalmológico de Brasília, 2Cataract Department, Centro de Estudos Oftalmológicos Renato Ambrósio, Brasília, 3Cataract Department, Fundação Altino Ventura, Recife, Brazil; 4Cataract Department, University of Edinburgh, Edinburgh, UK; 5Cataract Department, Universidade de São Paulo, São Paulo, 6Cataract Department, Hospital de Olhos de Pernambuco, Recife, 7Cataract Department, Hospital de Olhos Francisco Vilar, Teresina, 8Cataract Department, ProVisão, João Pessoa, Brazil Purpose: The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B).Methods: This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve.Results: Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare.Conclusion: Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. Keywords: trifocal, multifocal, pseudophakia, cataract