A multi-topographical-instrument analysis: the breast implant texture measurement
- 1 June 2017
- journal article
- research article
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 5 (2) , 025004
Abstract
Capsular contracture is a major complication after implant-based breast augmentation. To address this tissue reaction, most manufacturers texture the outer breast implant surfaces with calibrated salt grains. However, the analysis of these surfaces on sub-micron scales has been under-studied. This scale range is of interest to understand the future of silicone particles potentially released from the implant surface and the aetiology of newly reported complications, such as Anaplastic Large Cell Lymphoma. The surface measurements were accomplished by tomography and by two optical devices based on interferometry and on focus variation. The robustness of the measurements was investigated from the tissue scale to the cellular scale. The macroscopic pore-based structure of the textured implant surfaces is consistently measured by the three instruments. However, the multi-scale analyses start to be discrepant in a scale range between 50 µm and 500 µm characteristic of a finer secondary roughness regardless of the pore shape. The focus variation and the micro-tomography would fail to capture this roughness regime because of a focus-related optical artefact and of step-shaped artefact respectively.Keywords
This publication has 16 references indexed in Scilit:
- Characterization of Breast Implant Surfaces, Shapes, and Biomechanics: A Comparison of High Cohesive Anatomically Shaped Textured Silicone, Breast Implants from Three Different ManufacturersAesthetic Plastic Surgery, 2016
- Anaplastic Large Cell Lymphoma Occurring in Women with Breast ImplantsPlastic and Reconstructive Surgery, 2015
- Benefits and Limitations of Macrotextured Breast Implants and Consensus Recommendations for Optimizing Their EffectivenessAesthetic Surgery Journal, 2014
- Breast Implant Surface Development: Perspectives on Development and ManufactureAesthetic Surgery Journal, 2011
- Breast Implant Complication Review: Double Capsules and Late SeromasPlastic and Reconstructive Surgery, 2011
- Handbook of Surface and Nanometrology2010
- Identification of Three Regimes of Behavior for Cell Attachment on Topographically Patterned SubstratesLangmuir, 2008
- Textured Surface Breast Implants in the Prevention of Capsular Contracture among Breast Augmentation Patients: A Meta-Analysis of Randomized Controlled TrialsPlastic and Reconstructive Surgery, 2006
- Effect of porosity on the osteointegration and bone ingrowth of a weight-bearing nickel–titanium bone graft substituteBiomaterials, 2003
- Comparison of the Capsular Response to the Biocell RTV and Mentor 1600 Siltex Breast Implant Surface Texturing: A Scanning Electron Microscopic StudyPlastic and Reconstructive Surgery, 2001