Charles Garabédian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Charles Garabédian has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Karine Anselme
IS2M, Mulhouse, France
1 shared publicationMaxence Bigerelle
LAMIH, UMR CNRS 8201, UVHC, Valenciennes, France
1 shared publicationMichael Atlan
UPMC Faculté de Médicine, Paris, France
1 shared publicationRaphaël Deltombe
LAMIH, UMR CNRS 8201, UVHC, Valenciennes, France
1 shared publicationRémi Delille
LAMIH, UMR CNRS 8201, UVHC, Valenciennes, France
1 shared publication
Latest Publications
- 1 June 2017
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 5 (2) , 025004
A multi-topographical-instrument analysis: the breast implant texture measurement
Capsular contracture is a major complication after implant-based breast augmentation. To address this tissue reaction, most manufacturers texture the outer breast implant surfaces with calibrated salt grains. However, the analysis of these surfaces on sub-micron scales has been under-studied. This scale range is of interest to understand the future of silicone particles potentially released from the implant surface and the aetiology of newly reported complications, such as Anaplastic Large Cell Lymphoma. The surface measurements were accomplished by tomography and by two optical devices based on interferometry and on focus variation. The robustness of the measurements was investigated from the tissue scale to the cellular scale. The macroscopic pore-based structure of the textured implant surfaces is consistently measured by the three instruments. However, the multi-scale analyses start to be discrepant in a scale range between 50 µm and 500 µm characteristic of a finer secondary roughness regardless of the pore shape. The focus variation and the micro-tomography would fail to capture this roughness regime because of a focus-related optical artefact and of step-shaped artefact respectively.
- 1 June 2017
- Published by IOP Publishing in Surface Topography: Metrology and Properties
- Vol. 5 (2) , 025004
A multi-topographical-instrument analysis: the breast implant texture measurement
Capsular contracture is a major complication after implant-based breast augmentation. To address this tissue reaction, most manufacturers texture the outer breast implant surfaces with calibrated salt grains. However, the analysis of these surfaces on sub-micron scales has been under-studied. This scale range is of interest to understand the future of silicone particles potentially released from the implant surface and the aetiology of newly reported complications, such as Anaplastic Large Cell Lymphoma. The surface measurements were accomplished by tomography and by two optical devices based on interferometry and on focus variation. The robustness of the measurements was investigated from the tissue scale to the cellular scale. The macroscopic pore-based structure of the textured implant surfaces is consistently measured by the three instruments. However, the multi-scale analyses start to be discrepant in a scale range between 50 µm and 500 µm characteristic of a finer secondary roughness regardless of the pore shape. The focus variation and the micro-tomography would fail to capture this roughness regime because of a focus-related optical artefact and of step-shaped artefact respectively.