Inner‐volume echo volumar imaging (IVEVI) for robust fetal brain imaging
- 8 November 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (1) , 279-285
Abstract
Purpose: Fetal functional MRI studies using conventional 2‐dimensional single‐shot echo‐planar imaging sequences may require discarding a large data fraction as a result of fetal and maternal motion. Increasing the temporal resolution using echo volumar imaging (EVI) could provide an effective alternative strategy. Echo volumar imaging was combined with inner volume (IV) imaging (IVEVI) to locally excite the fetal brain and acquire full 3‐dimensional images, fast enough to freeze most fetal head motion.Methods: IVEVI was implemented by modifying a standard multi‐echo echo‐planar imaging sequence. A spin echo with orthogonal excitation and refocusing ensured localized excitation. To introduce weighting and to save time, the k‐space center was shifted relative to the spin echo. Both single and multi‐shot variants were tested. Acoustic noise was controlled by adjusting the amplitude and switching frequency of the readout gradient. Image‐based shimming was used to minimize B0 inhomogeneities within the fetal brain.Results: The sequence was first validated in an adult. Eight fetuses were scanned using single‐shot IVEVI at a 3.5 × 3.5 × 5.0 mm3 resolution with a readout duration of 383 ms. Multishot IVEVI showed reduced geometric distortions along the second phase‐encode direction.Conclusions: Fetal EVI remains challenging. Although effective echo times comparable to the values of fetal cortical gray matter at 3 T could be achieved, controlling acoustic noise required longer readouts, leading to substantial distortions in single‐shot images. Although multishot variants enabled us to reduce susceptibility‐induced geometric distortions, sensitivity to motion was increased. Future studies should therefore focus on improvements to multishot variants. Magn Reson Med 80:279–285, 2018. © 2017 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- Fundação para a Ciência e a Tecnologia (UID/BIO/00645/2013, IF/00364/2013)
- European Research Council (319456)
- Medical Research Council (MR/K006355/1)
This publication has 38 references indexed in Scilit:
- Cross-Hemispheric Functional Connectivity in the Human Fetal BrainScience Translational Medicine, 2013
- High-Speed Real-Time Resting-State fMRI Using Multi-Slab Echo-Volumar ImagingFrontiers in Human Neuroscience, 2013
- Emergence of resting state networks in the preterm human brainProceedings of the National Academy of Sciences of the United States of America, 2010
- Longitudinal Analysis of Neural Network Development in Preterm InfantsCerebral Cortex, 2010
- Fetal cortical activation to sound at 33 weeks of gestation: A functional MRI studyNeuroImage, 2008
- Localized echo-volume imaging methods for functional MRIJournal of Magnetic Resonance Imaging, 1997
- An assessment of the intrauterine sound intensity level during obstetric echo-planar magnetic resonance imagingBritish Journal of Radiology, 1995
- Echo‐volume imagingMagnetic Resonance in Medicine, 1994
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- Volumar imaging using NMR spin echoes: echo-volumar imaging (EVI) at 0.1 TJournal of Physics E: Scientific Instruments, 1989