AGAndreia S. Gaspar

Andreia S. Gaspar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreia S. Gaspar has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    K‐ CC ‐ MoCo : A Fast k ‐Space‐Based Respiratory Motion Correction for Highly Accelerated First‐Pass Perfusion Cardiovascular MR

    by Elisa Moya‐Sáez, Rosa‐María Menchón‐Lara, Javier Sánchez‐González, Catarina N. Carvalho, Andreia S. Gaspar, Carlos Real, Carlos Galán‐Arriola, Rita G. Nunes, Borja Ibanez, Teresa M. Correia, et al.

    Purpose: First‐pass perfusion cardiovascular MR (FPP‐CMR) enables the non‐invasive diagnosis of microcirculation and coronary artery disease. In free‐breathing FPP‐CMR, motion correction is usually performed in the image domain, requiring an initial reconstruction. This fact hinders its use in model‐based and deep learning reconstructions, which present remarkable performance in obtaining high‐quality images from highly accelerated acquisitions. We address this challenge by estimating and correcting respiratory motion in free‐breathing FPP‐CMR directly in k ‐space. Methods: We propose K‐CC‐MoCo, an inter‐frame rigid motion correction approach formulated exclusively in k ‐space that handles dynamic contrast through a specifically targeted design of the normalized cross‐correlation (CC) objective function to deal with the dynamic contrast. In addition, an ROI‐based coil‐compression approach was employed to focus the optimization on the heart region. The proposed method was compared to state‐of‐the‐art image‐based registration using a digital phantom and real free‐breathing acquisitions with different accelerations. Results: The proposed k ‐space‐based method is approximately 2× faster and can correct respiratory motion even at high acceleration factors (up to 50×), where the image‐based method fails due to severe undersampling artifacts. Notably, after K‐CC‐MoCo, the time‐averaged images are visibly less blurred. Quantitative metrics (SSIM, etc.) support this conclusion. Conclusion: K‐CC‐MoCo outperforms image‐based correction in free‐breathing FPP‐CMR acquisitions accelerated up to 50×. Respiratory motion is estimated and corrected in k ‐space, enabling its use for model‐based and/or deep learning reconstructions from highly accelerated scans.


  • Open Access

    Repeatability ofOpen‐MOLLI: An open‐source inversion recovery myocardialT1mapping sequence for fast prototyping

    by Andreia S. Gaspar, Nuno A. Silva, António M. Ferreira, Rita G. Nunes

    Purpose: To develop an open‐source prototype of myocardial T1 mapping (Open‐MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open‐MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter‐scanner and cross‐vendor reproducibility studies.Methods: Open‐MOLLI is an inversion‐recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open‐MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open‐MOLLI and MOLLI were repeated in the same session (test–retest).Results: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1vial3 = 1027 ms): T1MOLLI = 1011 ± 24 ms versus T1Open‐MOLLI = 1009 ± 20 ms. In vivo T1 estimates were similar between Open‐MOLLI and MOLLI (T1MOLLI = 1004 ± 33 ms vs. T1Open‐MOLLI = 998 ± 52 ms), with a mean difference of −17 ms (p = 0.20), despite noisier Open‐MOLLI weighted images and maps. Repeatability measures were slightly higher for Open‐MOLLI (RCMOLLI = 3.0% vs. RCOpen‐MOLLI = 4.4%).Conclusion: The open‐source sequence Open‐MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open‐MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.


  • Open Access

    Open‐source myocardial T1 mapping with simultaneous multi‐slice acceleration: Combining an auto‐calibrated blipped‐bSSFP readout with VERSE‐MB pulses

    by Andreia S. Gaspar, Nuno A. Silva, Anthony N. Price, António M. Ferreira, Rita G. Nunes

    Purpose: Enabling fast and accessible myocardial T1 mapping is crucial for extending its clinical application. We introduce Open‐MOLLI‐SMS combining simultaneous multi‐slice (SMS) with auto‐calibration and variable‐rate selective excitation (VERSE)‐multiband pulses to obtain all slices in a fast single‐shot T1 mapping sequence.Methods: Open‐MOLLI‐SMS was developed by integrating SMS with the open‐source method Open‐MOLLI previously implemented in Pulseq. Three methods were integrated for Open‐MOLLI‐SMS: (1) auto‐calibration blip patterns to ensure consistency between the data and coil information; (2) a blipped‐balanced SSFP (bSSFP) readout to induce controlled aliasing in parallel imaging shifts without disturbing the bSSFP frequency response; and (3) a VERSE‐multiband pulse for minimizing the achievable TR and the specific absortion rate (SAR) impact of SMS. Two (SMS2) or three (SMS3) slices were excited simultaneously and encoded with an in‐plane acceleration factor of 2. Experiments were performed in the International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology phantom and five healthy volunteers.Results: Phantom results show accurate T1 estimates for reference values between 400 to 2200 ms. Artifacts were visible for Open‐MOLLI‐SMS3 but not replicated in vivo. In vivo Open‐MOLLI‐SMS (T1SMS2 = 993 ± 10 ms; T1SMS3 = 1031 ± 17 ms) provided similar values to mean T1 single‐band Open‐MOLLI estimates (T1Open‐MOLLI = 1005 ± 47 ms). Open‐MOLLI‐SMS2 provided the closest estimates to the reference.Conclusion: This proof‐of‐principle implementation study demonstrates the feasibility of speeding up T1‐mapping acquisitions and increasing coverage by combining auto‐calibration strategies with a blipped‐bSFFP readout and VERSE multiband RF excitation pulses. The proposed methodology was built on the Open‐MOLLI mapping sequence, which provides a fast means for prototyping and enables open‐source sharing of the method.


  • Open Access

    Open-source magnetic resonance imaging acquisition: Data and documentation for two validated pulse sequences

    by Gehua Tong, Andreia S. Gaspar, Enlin Qian, Keerthi Sravan Ravi, John Thomas Vaughan, Rita G. Nunes, Sairam Geethanath


  • Open Access

    Myocardial T1 mapping with magnetic resonance imaging – a useful tool to understand the diseased heart

    by Andreia S. Gaspar, Sérgio Maltês, Hugo Marques, Rita G. Nunes, António Ferreira


  • Improving parametric estimation in the brain from multispin‐echo sequences using a fusion bootstrap moves solver

    by Andreia C. Freitas, Andreia S. Gaspar, Inês Sousa, Rui P. A. G. Teixeira, Joseph V. Hajnal, Rita G. Nunes

    Purpose To simultaneously estimate the field (along with the T2) in the brain with multispin-echo (MSE) sequences and dictionary matching. Methods T2 mapping provides clinically relevant information such as in the assessment of brain degenerative diseases. It is commonly obtained with MSE sequences, and accuracy can be further improved by matching the MSE signal to a precomputed dictionary of echo-modulation curves. For additional T1 quantification, transmit field knowledge is also required. Preliminary work has shown that although simultaneous brain estimation along with T2 is possible, it presents a bimodal distribution with the main peak coinciding with the true value. By taking advantage of this, the maps are expected to be spatially smooth by applying an iterative method that takes into account each pixel neighborhood known as the fusion bootstrap moves solver (FBMS). The effect of the FBMS on accuracy and piecewise smoothness is investigated and different spatial regularization levels are compared. Total variation regularization was used for both and T2 simultaneous estimation because of its simplicity as an initial proof-of-concept; future work could explore non edge-preserving regularization independently for . Results Improvements in accuracy (up to 45.37% and 16.81% error decrease) and recovery of spatially homogeneous maps are shown in simulations and in vivo 3.0T brain data, respectively. Conclusion Accurate estimated values can be obtained from widely available MSE sequences while jointly estimating T2 maps with the use of echo-modulation curve matching and FBMS at no further cost.

  • Diffusion MRI Outside the Brain

    by Rita G. Nunes, Luísa Nogueira, Andreia S. Gaspar, Nuno Adubeiro, Sofia Brandão


  • Open Access

    Accelerated magnetic resonance fingerprinting using soft-weighted key-hole (MRF-SOHO)

    by Gastao Cruz, Torben Schneider, Tom Bruijnen, Andreia S Gaspar, René M Botnar, Claudia Prieto

    To develop a novel approach for highly accelerated Magnetic Resonance Fingerprinting (MRF) acquisition. The proposed method combines parallel imaging, soft-gating and key-hole approaches to highly accelerate MRF acquisition. Slowly varying flip angles (FA), commonly used during MRF acquisition, lead to a smooth change in the signal contrast of consecutive time-point images. This assumption enables sharing of high frequency data between different time-points, similar to what is done in some dynamic MR imaging methods such as key-hole. The proposed approach exploits this information using a SOft-weighted key-HOle (MRF-SOHO) reconstruction to achieve high acceleration factors and/or increased resolution without compromising image quality or increasing scan time. MRF-SOHO was validated on a standard T1/T2 phantom and in in-vivo brain acquisitions reconstructing T1, T2 and proton density parametric maps. Accelerated MRF-SOHO using less data per time-point and less time-point images enabled a considerable reduction in scan time (up to 4.6x), while obtaining similar T1 and T2 accuracy and precision when compared to zero-filled MRF reconstruction. For the same number of spokes and time-points, the proposed method yielded an enhanced performance in quantifying parameters than the zero-filled MRF reconstruction, which was verified with 2, 1 and 0.7 (sub-millimetre) resolutions. The proposed MRF-SOHO enabled a 4.6x scan time reduction for an in-plane spatial resolution of 2x2 mm2 when compared to zero-filled MRF and enabled sub-millimetric (0.7x0.7 mm2) resolution MRF.


  • Open Access

    Optimizing maternal fat suppression with constrained image‐based shimming in fetal MR

    by Andreia S. Gaspar, Rita G. Nunes, Giulio Ferrazzi, Emer J. Hughes, Jana Hutter, Shaihan J. Malik, Laura McCabe, Kelly P. Baruteau, Mary A. Rutherford, Joseph V. Hajnal, et al.

    Purpose: Echo planar imaging (EPI) is the primary sequence for functional and diffusion MRI. In fetal applications, the large field of view needed to encode the maternal abdomen leads to prolonged EPI readouts, which may be further extended due to safety considerations that limit gradient performance. The resulting images become very sensitive to water‐fat shift and susceptibility artefacts. The purpose of this study was to reduce artefacts and increase stability of EPI in fetal brain imaging, balancing local field homogeneity across the fetal brain with longer range variations to ensure compatibility with fat suppression of the maternal abdomen.Methods: Spectral Pre‐saturation with Inversion‐Recovery (SPIR) fat suppression was optimized by investigating SPIR pulse frequency offsets. Subsequently, fetal brain EPI data were acquired using image‐based (IB) shimming on 6 pregnant women by (1) minimizing B0 field variations within the fetal brain (localized IB shimming) and (2) with added constraint to limit B0 variation in maternal fat (fat constrained IB shimming).Results: The optimal offset for the SPIR pulse at 3 Tesla was 550 Hz. Both shimming approaches had similar performances in terms of B0 homogeneity within the brain, but constrained IB shimming enabled higher fat suppression efficiency.Conclusion: Optimized SPIR in combination with constrained IB shimming can improve maternal fat suppression while minimizing EPI distortions in the fetal brain.


  • Inner‐volume echo volumar imaging (IVEVI) for robust fetal brain imaging

    by Rita G. Nunes, Giulio Ferrazzi, Anthony N. Price, Jana Hutter, Andreia S. Gaspar, Mary A. Rutherford, Joseph V. Hajnal

    Purpose: Fetal functional MRI studies using conventional 2‐dimensional single‐shot echo‐planar imaging sequences may require discarding a large data fraction as a result of fetal and maternal motion. Increasing the temporal resolution using echo volumar imaging (EVI) could provide an effective alternative strategy. Echo volumar imaging was combined with inner volume (IV) imaging (IVEVI) to locally excite the fetal brain and acquire full 3‐dimensional images, fast enough to freeze most fetal head motion.Methods: IVEVI was implemented by modifying a standard multi‐echo echo‐planar imaging sequence. A spin echo with orthogonal excitation and refocusing ensured localized excitation. To introduce weighting and to save time, the k‐space center was shifted relative to the spin echo. Both single and multi‐shot variants were tested. Acoustic noise was controlled by adjusting the amplitude and switching frequency of the readout gradient. Image‐based shimming was used to minimize B0 inhomogeneities within the fetal brain.Results: The sequence was first validated in an adult. Eight fetuses were scanned using single‐shot IVEVI at a 3.5 × 3.5 × 5.0 mm3 resolution with a readout duration of 383 ms. Multishot IVEVI showed reduced geometric distortions along the second phase‐encode direction.Conclusions: Fetal EVI remains challenging. Although effective echo times comparable to the values of fetal cortical gray matter at 3 T could be achieved, controlling acoustic noise required longer readouts, leading to substantial distortions in single‐shot images. Although multishot variants enabled us to reduce susceptibility‐induced geometric distortions, sensitivity to motion was increased. Future studies should therefore focus on improvements to multishot variants. Magn Reson Med 80:279–285, 2018. © 2017 International Society for Magnetic Resonance in Medicine.