The implementation of a system for managing analytical quality in networked laboratories
Authors:
- 21 February 2011
- journal article
- Published by SAGE Publications in Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Vol. 48 (2) , 136-146
Abstract
Background: In a network of laboratories analytical variability between instruments, even of the same type, may exist for reasons beyond the control of laboratory staff. Controlling variability is a prerequisite for the application of shared reference ranges and for ensuring the transferability of patient test results. Controlling variability requires a robust, non-conventional quality system to detect poor performance of analysers that are geographically distant. Essential to this quality system is a set of well-defined quality specifications. Methods: The approach used in our study started with (1) selection of a model for quality specifications based on biological variation; the ‘three-level model’ (TLM) was selected on the basis of its flexibility to accommodate various levels of analytical performance; (2) determination of the performance characteristics of the 71 analytes measured in core biochemistry in terms of imprecision and bias; (3) defining quality requirements in the form of imprecision, bias and total error for 71 analytes measured routinely in core biochemistry; and (4) developing software to assist a consistent wide application of the quality specifications and to monitor analytical indices to the common quality specifications. Results: In this paper we describe how we have implemented this model across our network. Forty-six of the 71 analytes in our core laboratory repertoire were allocated to the TLM. We were able to demonstrate equivalence of results on all analysers, for 42 out of 46 analytes allocated to this model. Conclusions: We propose that other networked laboratories should investigate the suitability of this quality system for use in their network.Keywords
This publication has 10 references indexed in Scilit:
- Macroprolactin on the Advia Centaur: experience with 409 patients over a three-year periodAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2009
- Short- and Long-Term Biological Variation in Cardiac Troponin I Measured with a High-Sensitivity Assay: Implications for Clinical PracticeClinical Chemistry, 2009
- Universal Definition of Myocardial InfarctionCirculation, 2007
- Implementing the Stockholm Conference hierarchy of objective quality criteria in a routine laboratoryClinical Chemistry and Laboratory Medicine (CCLM), 2007
- Test result variation and the quality of evidence-based clinical guidelinesClinica Chimica Acta, 2004
- Analytical quality specifications for common reference intervalsClinical Chemistry and Laboratory Medicine (CCLM), 2004
- Quality specifications based on analysis of effects of performance on clinical decision-makingScandinavian Journal of Clinical and Laboratory Investigation, 1999
- Current databases on biological variation: pros, cons and progressScandinavian Journal of Clinical and Laboratory Investigation, 1999
- Proposals for Setting Generally Applicable Quality Goals Solely Based on BiologyAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1997
- Desirable standards of performance for therapeutic drug monitoring.Clinical Chemistry, 1987