Detection Efficiency Modeling and Joint Activity and Attenuation Reconstruction in Non-TOF 3-D PET From Multiple-Energy Window Data
- 8 March 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 6 (1) , 87-97
Abstract
Emission-based attenuation correction (AC) meth-ods offer the possibility of overcoming quantification errors induced by conventional MR-based approaches in PET/MR imaging. However, the joint problem of determining AC and the activity of interest is strongly ill-posed in non-TOF PET. This can be improved by exploiting the extra information arising from low energy window photons, but the feasibility of this approach has only been studied with relatively simplistic analytic simulations so far. This manuscript aims to address some of the remaining challenges needed to handle realistic measurements; in particular, the detection efficiency (“normalisation”) estimation for each energy window is investigated. An energy-dependent detection efficiency model is proposed, accounting for the presence of unscattered events in the lower energy window due to detector scatter. Geometric calibration factors are estimated prior to the reconstruction for both scattered and unscattered events. Different reconstruction methods are also compared. Results show that geometric factors differ markedly between the energy windows and that our analytical model correspond in good approximation to Monte Carlo simulation; the multiple energy window reconstruction appears sensitive to input/model mismatch. Our method applies to Monte Carlo generated data but can be extended to measured data. This study is restricted to single scatter events.Keywords
This publication has 39 references indexed in Scilit:
- Reconstruction of scattered and unscattered PET coincidences using TOF and energy informationPhysics in Medicine & Biology, 2012
- Determination of the effective atomic and mass numbers for mixture and compound materials in high energy photon interactionsJournal of Radioanalytical and Nuclear Chemistry, 2012
- Time-of-flight PET data determine the attenuation sinogram up to a constantPhysics in Medicine & Biology, 2012
- STIR: software for tomographic image reconstruction release 2Physics in Medicine & Biology, 2012
- 4D XCAT phantom for multimodality imaging researchMedical Physics, 2010
- Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinogramsIEEE Transactions on Medical Imaging, 1999
- A Single Scatter Simulation Technique for Scatter Correction in 3D PET1996
- Model-based scatter correction for fully 3D PETPhysics in Medicine & Biology, 1996
- Detector efficiency and Compton scatter in fully 3D PETIEEE Transactions on Nuclear Science, 1995
- Über die Streuung von Strahlung durch freie Elektronen nach der neuen relativistischen Quantendynamik von DiracZeitschrift für Physik, 1929