  • Phantom-based evaluation of a novel tomographic ultra-fast molecular breast imaging prototype

    by Alexander Cherlin, Nathan Atkins, Matthew Exley, Kjell Erlandsson, Andras Wirth, Ian Baistow, Brian Hutton, Michael O’COnnor, Carrie Hruska, Kris Thielemans

    A novel stationary tomographic ultra-fast molecular breast imaging (UFMBI) technology was developed to reduce acquisition time and radiation dose of molecular breast imaging (MBI), enabling its wider acceptance for supplemental dense breast screening. The system combines a stationary dual-head gamma camera made of cadmium zinc telluride (CZT) detectors with densely packed multi-pinhole collimators and novel de-multiplexing (MX) reconstruction methods, exploiting the ultra-high 3D position resolution of CZT detectors and their excellent energy resolution. A small field-of-view (FoV) prototype (132 mm × 88 mm) was designed, built and calibrated. Raw detector data were processed using a machine-learning model providing 10 × 10 subpixelisation of 2 mm pixels in 5 mm thick CZT detectors and depth-of-interaction estimation from anode signals alone. Tomographic images were reconstructed using an OSEM algorithm, including de-MX and corrections for attenuation and collimator response. The prototype was evaluated using a 99m Tc-filled phantom with lesions of different sizes and uniform background acquired separately. Prototype performance was compared with a clinical planar MBI system by imaging 99m Tc-infused gel phantoms, with lesion detectability assessed via contrast-to-noise ratio (CNR). The results from the spheres’ phantom indicated that 5–7 mm diameter lesions with tumour-to-background ratios of 10–20:1 were detectable even with a dose/time reduction factor (DRF) of 8 relative to current MBI clinical practice. The gel phantom experiments showed that, with equal activity concentration and scanning time (DRF = 1), the UFMBI prototype provided 3.0–3.5-fold CNR of the clinical planar system depending on the lesion activity and position within the FoV; with DRF of 6, UFMBI provided 1.8–2.1-fold CNR of the clinical system, improving to 2.4–3.4-fold with application of non-local means noise filtering. These results demonstrate the feasibility of UFMBI as a low-dose, high throughput approach and support its further development toward cancer screening of dense breasts and image-guided biopsy applications.

  • Open Access

    Use of Monte Carlo Uncertainty Propagation to determine Quantitative SPECT Imaging Uncertainty

    by Andrew P. Robinson, Daniel Deidda, Ana M. Denis-Bacelar, Kelley M. Ferreira, Andrew J. Fenwick, Warda Heetun, Brian F. Hutton, James Scuffham, Kris Thielemans

    Single Photon Emission Computed Tomography (SPECT) is now commonly used for quantitative imaging (QI), as such the results from SPECT based measurements should be reported with a quantitative indication of the quality of the result. In this study a novel methodology to construct a measurement model for a clinical SPECT system based on List Mode data is presented. Input probability density functions (PDFs) are determined for all calibrations and corrections applied to the system, and a Monte Carlo method for propagation of probability distributions is used to assess measurement uncertainty. The methodology is applied to estimate the uncertainties of quantitative measurements using phantoms filled with 99mTc. Details of the PDF for the List Mode data events and correction tables applied within the commercial system software are presented. The effect of correlated corrections on the uncertainty of reconstructed SPECT images is evaluated for the first time. The potential for this development to allow rigorous uncertainty budgets to be developed for SPECT based clinical procedures is discussed.

  • Nuclear medicine imaging

    by John C. Dickson, Brian F. Hutton, Sarah J. McQuaid, Kris Thielemans

  • Challenges in Acquiring Clinical Simultaneous SPECT-MRI on a PET-MRI Scanner

    by Ashley J. Morahan, Ilenia D’aDda, Kjell Erlandsson, Marco Carminati, Marilena Rega, Darren Walls, Carlo Fiorini, Brian F. Hutton

    The INSERT is the world’s first clinical SPECTMRI brain imaging system based on scintillation detectors with a SiPM readout. Here we demonstrate its use within a clinical MRI environment for the first time. Using a standard transmit-receive head coil, and with an appropriate selection of a custom MRI sequence (GRE), we overcome mutual interference. The INSERT and its bulky 50 kg tungsten collimator introduce magnetic field inhomogeneity. Due to the specific MRI-compatible collimator design, inhomogeneity is compensated by shimming, leading to simultaneous acquisition. We process the SPECT data acquired alongside the MRI sequence to evaluate the SPECT system performance and the impact of the MRI. Finally, we present a set of simultaneous SPECT-MRI acquisitions, demonstrating multimodal imaging capabilities, albeit with a limited MRI sequence.


  • Design of a Low-Dose, Stationary, Tomographic Molecular Breast Imaging System Using 3-D Position Sensitive CZT Detectors

    by Kjell Erlandsson, Andras Wirth, Kris Thielemans, Ian Baistow, Alexander Cherlin, Brian F. Hutton

    Molecular Breast Imaging (MBI) has been shown to have high sensitivity for lesion detection, particularly in patients with dense breasts where conventional mammography is limited. However, relatively high radiation dose and long imaging time are limiting factors. Most current MBI systems are based on planar imaging. Improved performance can be achieved using tomographic techniques, which normally involve detector motion. Our goal is to develop a low-dose stationary tomographic MBI system with similar or better performance in terms of lesion detection compared to planar MBI. The proposed system utilizes two opposing CZT detectors with high intrinsic resolution and depth of interaction (DOI) capability, combined with densely packed multi-pinhole collimators. This leads to improved efficiency and adequate angular sampling, but also to significant multiplexing (MX), which can result in artefacts. We have developed de-MX algorithms that take advantage of the DOI information. We have performed both analytic and Monte Carlo simulations to demonstrate the feasibility, optimize the design and investigate the expected performance of the proposed system. Lesion detectability was preserved with reduction of acquisition time (or radiation dose) by a factor of 2 compared to planar images at the lowest reported dose. The first prototype is under evaluation at Kromek.


  • Open Access

    An Investigation of Stochastic Variance Reduction Algorithms for Relative Difference Penalized 3D PET Image Reconstruction

    by Robert Twyman, Simon Arridge, Zeljko Kereta, Bangti Jin, Ludovica Brusaferri, Sangtae Ahn, Charles W. Stearns, Brian F. Hutton, Irene A. Burger, Fotis Kotasidis, et al.

    Penalised PET image reconstruction algorithms are often accelerated during early iterations with the use of subsets. However, these methods may exhibit limit cycle behaviour at later iterations due to variations between subsets. Desirable converged images can be achieved for a subclass of these algorithms via the implementation of a relaxed step size sequence, but the heuristic selection of parameters will impact the quality of the image sequence and algorithm convergence rates. In this work, we demonstrate the adaption and application of a class of stochastic variance reduction gradient algorithms for PET image reconstruction using the relative difference penalty and numerically compare convergence performance to BSREM. The two investigated algorithms are: SAGA and SVRG. These algorithms require the retention in memory of recently computed subset gradients, which are utilised in subsequent updates. We present several numerical studies based on Monte Carlo simulated data and a patient data set for fully 3D PET acquisitions. The impact of the number of subsets, different preconditioners and step size methods on the convergence of regions of interest values within the reconstructed images is explored. We observe that when using constant preconditioning, SAGA and SVRG demonstrate reduced variations in voxel values between subsequent updates and are less reliant on step size hyper-parameter selection than BSREM reconstructions. Furthermore, SAGA and SVRG can converge significantly faster to the penalised maximum likelihood solution than BSREM, particularly in low count data.


  • A Statistical DOI Estimation Algorithm for a SiPM-Based Clinical SPECT Insert

    by Ilenia D'ADda, Ashley J. Morahan, Marco Carminati, Kjell Erlandsson, Michael Ljungberg, Brian F. Hutton, Carlo Fiorini

    A prototype clinical brain SPECT insert has been designed for use in simultaneous SPECT/MRI. The system utilises novel slit-slat collimators which, like pinhole collimators, suffers from parallax errors due to the large incident angle of photons. A statistical algorithm has been developed to determine the depth-of-interaction (DOI) with a view to improving image performance. The importance of DOI correction was demonstrated using Monte Carlo simulation. This simulation also indicated that 4 DOI layers (3×1.5 mm+3.5 mm) may be sufficient. The improvement in event localisation was demonstrated on a single detector before implementing the algorithm on the full clinical prototype where some limitations in event localisation in layers close to the readout plane were observed. Nevertheless DOI enabled the rejection of poorly localised events with improved resolution in reconstructed line sources.


  • Open Access

    A Demonstration of STIR-GATE-Connection

    by Robert Twyman, Ludovica Brusaferri, Elise C. Emond, Francesca Leek, Simon Arridge, Brian F. Hutton, Vesna Cuplov, Kris Thielemans

    We present the first open-source version of STIR-GATE-Connection, a project that aims to provide an easy-to-use pipeline to simulate realistic PET data using GATE, followed by quantitative reconstruction using STIR. Monte Carlo simulations and image reconstruction are powerful research tools for emission tomography that can assist with the design of new medical imaging devices as well as the evaluation of novel image reconstruction algorithms and various correction techniques. STIR-GATE-Connection is a collection of scripts that aid with the: (i) setup of a realistic GATE simulation of a voxelised phantom using a user selected scanner configuration, (ii) conversion of the output list mode data into STIR compatible sinograms, and (iii) computation of additive and multiplicative data corrections for Poisson image reconstruction using STIR. In this work, we demonstrate example usage of these steps. A public release of STIR-GATE-Connection, licensed under the Apache 2.0 License, can be downloaded at: http://www.github.com/UCL/STIR-GATE-Connection.


  • Detection Efficiency Modeling and Joint Activity and Attenuation Reconstruction in Non-TOF 3-D PET From Multiple-Energy Window Data

    by Ludovica Brusaferri, Elise C. Emond, Alexandre Bousse, Robert Twyman, Alexander C. Whitehead, David Atkinson, Sebastien Ourselin, Brian F. Hutton, Simon Arridge, Kris Thielemans

    Emission-based attenuation correction (AC) meth-ods offer the possibility of overcoming quantification errors induced by conventional MR-based approaches in PET/MR imaging. However, the joint problem of determining AC and the activity of interest is strongly ill-posed in non-TOF PET. This can be improved by exploiting the extra information arising from low energy window photons, but the feasibility of this approach has only been studied with relatively simplistic analytic simulations so far. This manuscript aims to address some of the remaining challenges needed to handle realistic measurements; in particular, the detection efficiency (“normalisation”) estimation for each energy window is investigated. An energy-dependent detection efficiency model is proposed, accounting for the presence of unscattered events in the lower energy window due to detector scatter. Geometric calibration factors are estimated prior to the reconstruction for both scattered and unscattered events. Different reconstruction methods are also compared. Results show that geometric factors differ markedly between the energy windows and that our analytical model correspond in good approximation to Monte Carlo simulation; the multiple energy window reconstruction appears sensitive to input/model mismatch. Our method applies to Monte Carlo generated data but can be extended to measured data. This study is restricted to single scatter events.