X-Ray Microanalysis Combined with Monte Carlo Simulation for the Analysis of Layered Thin Films: The Case of Carbon Contamination
Authors:
- 16 March 2009
- journal article
- microanalysis
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 15 (2) , 99-105
Abstract
A previously developed Monte Carlo code has been extended to the X-ray microanalysis in a (scanning) transmission electron microscope of plan sections, consisting of bilayers and triple layers. To test the validity of this method for quantification purposes, a commercially available NiOx (x ∼ 1) thin film, deposited on a carbon layer, has been chosen. The composition and thickness of the NiO film and the thickness of the C support layer are obtained by fitting to the three X-ray intensity ratios I(NiK)/I(OK), I(NiK)/I(CK), and I(OK)/I(CK). Moreover, it has been investigated to what extent the resulting film composition is affected by the presence of a contaminating carbon film at the sample surface. To this end, the sample has been analyzed both in the (recommended) “grid downward” geometry and in the upside/down (“grid upward”) situation. It is found that a carbon contaminating film of few tens of nanometers must be assumed in both cases, in addition to the C support film. Consequently, assuming the proper C/NiOx/C stack in the simulations, the Monte Carlo method yields the correct oxygen concentration and thickness of the NiOx film.Keywords
This publication has 17 references indexed in Scilit:
- The quantitative analysis of thin specimens: a review of progress from the Cliff‐Lorimer to the new ζ‐factor methodsJournal of Microscopy, 2006
- Thin film X-ray microanalysis with the analytical electron microscopeJournal of Analytical Atomic Spectrometry, 1999
- Experimental determination of light‐element k‐factors using the extrapolation technique: Oxygen segregation in aluminium nitrideJournal of Microscopy, 1992
- Applicability of the differential X-ray absorption method to the determinations of foil thickness and local composition in the analytical electron microscopePhilosophical Magazine A, 1989
- Monte carlo simulation of thin‐film X‐ray microanalysis at high energiesX-Ray Spectrometry, 1989
- An extrapolation method for the determination of Cliff‐Lorimer kAB factors at zero foil thicknessJournal of Microscopy, 1986
- Relative intensity factors for K, L and M shell x‐ray linesX-Ray Spectrometry, 1982
- The quantitative analysis of thin specimensJournal of Microscopy, 1975
- Applications of the method of impact parameter in collisionsProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1933
- Zur Theorie des Durchgangs schneller Korpuskularstrahlen durch MaterieAnnalen der Physik, 1930