Peak hip and knee joint moments during a sit-to-stand movement are invariant to the change of seat height within the range of low to normal seat height
Open Access
- 1 January 2014
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 27
Abstract
Previous studies have consistently reported that decreasing seat height increases the peak hip and knee joint moments; however, these findings may not apply to biomechanical changes at very low seat heights. The purpose of this study, therefore, was to examine the effect of a large range of seat heights on peak joint moments of the lower limb during a sit-to-stand (STS) movement. Eight healthy young subjects participated in this experiment. Each subject was instructed to stand up from six seat heights (10, 20, 30, 40, 50 and 60 cm). Joint moments were calculated with an inverse dynamics method. The sum of the hip and knee joint moments was used as the index to indicate the mechanical load of the STS movement. The effect of seat height on the mechanical load was examined with both analytical and experimental approaches. Through the analytical approach, it was revealed that the mechanical load of STS movements from low and normal seat heights (10 to 40 cm) always reaches its peak at or near the posture in which the thigh is horizontally positioned. This finding indicates that the peak value is invariant between the low and normal seat heights. Similar results were also found in the experimental approach. There were few significant differences in the peak mechanical load and the peak hip and knee joint moments between the low and normal seat heights, while they differed significantly between the low and high seat heights. This study concluded that, while the peak mechanical load and the peak hip and knee joint moments increase inversely to seat height within the range of high to normal seat height (60 to 40 cm), they are invariant to the change of seat height within the range of low to normal seat height (10 to 40 cm). These findings are useful for the design of chair, the improvement in the evaluation standard of minimum sit-to-stand height tests and the development of new muscular strength test.Keywords
This publication has 24 references indexed in Scilit:
- The concept and treatment of locomotive syndrome: its acceptance and spread in JapanJournal of Orthopaedic Science, 2011
- Biomechanical analysis of the relation between movement time and joint moment development during a sit-to-stand taskBioMedical Engineering OnLine, 2009
- Computation of the kinematics and the minimum peak joint moments of sit-to-stand movementsBioMedical Engineering OnLine, 2007
- A 30-s Chair-Stand Test as a Measure of Lower Body Strength in Community-Residing Older AdultsResearch Quarterly for Exercise and Sport, 1999
- Adjustments to Zatsiorsky-Seluyanov's segment inertia parametersJournal of Biomechanics, 1996
- Muscle Function and Mobility Biomechanics in the Elderly: An Overview of Some Recent ResearchThe Journals of Gerontology, Series A: Biological Sciences and Medical Sciences, 1995
- The effects of armrests and high seat heights on lower-limb joint load and muscular activity during sitting and risingErgonomics, 1992
- Analysis of standing up and sitting down in humans: Definitions and normative data presentationJournal of Biomechanics, 1990
- The influence of chair height on lower limb mechanics during risingJournal of Orthopaedic Research, 1989
- Multiple Comparison ProceduresJournal of Educational Statistics, 1989