Abstract
Volt-per-hertz ( $V/f$ ) control is one the simplest control structures developed for operating electric motor drives, including permanent magnet synchronous motor (PMSM) drives. This paper presents the development and testing of a $V/f$ control for PMSM drives that utilize a $3\phi$ wavelet modulated (WM) dc-ac power electronic converter (PEC). The wavelet modulation technique is characterized by the maximum scale ( $J$ ) and scale-time interval factor ( $\gamma$ ). The output voltage of a $3\phi$ WM dc-ac PEC has its magnitude directly dependent on $J$ , while its frequency and phase are dependent to $\gamma$ . These two parameters of the wavelet modulation technique can be used to implement a $V/f$ control for PMSM drives. The proposed $V/f$ control is featured with a stabilizing loop to correct the $V/f$ ratio, and improve the stability of the controlled PMSM drive. The $V/f$ control for a PMSM drive fed by a wavelet modulated dc-ac PEC, is implemented for performance testing using a laboratory 10 $-hp$ PMSM drive under different operating conditions. Performance results demonstrate stable, dynamic, and accurate responses, with minor sensitivities to the load torque and/or speed changes. Furthermore, test results demonstrate the ability to enhance the efficiency using the tested control for PMSM drives.
Funding Information
  • Natural Sciences and Engineering Research Council of Canada