Effects of Loading Levels on Harmonic Distortion in Power Transformers Due to GIC Flows
Authors:
- 29 October 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Abstract
Geomagnetically induced currents (GICs) are currents dominated by dc components that flow through grounding circuits into power systems. These currents are typically initiated by geomagnetic disturbances, and flow into power systems through power transformers with grounded windings. The flow of a GIC through a power transformer creates adverse impacts, including high levels of harmonic distortion in the currents flowing through the grounded windings, overheating of transformer windings, and significant disruptions in the reactive power flow through the affected transformer. Adverse impacts of GICs on power transformers depend on various factors, among which are the core design (multi-cores, 3-limb, or 5-limb), configuration of primary and secondary windings, and loading levels. This paper presents and discusses the effects of loading levels on the harmonic distortion due to GIC flows in power transformers. Tests are carried out using a laboratory power transformer with multi-core (three single phase transformers). Various values of GIC flows are tested for different loading levels. Test results conclude that the loading levels have minor ifluence on the harmonic distortion created by the GIC flow. In addition, test results show that the 2 nd harmonic component remains the dominant harmonic component due to the GIC flow in a power transformer, regardless of the loading level.Keywords
This publication has 40 references indexed in Scilit:
- Case Studies of Harmonic Distortion in Power Transformers Due to Geomagnetically Induced Current Flows2023
- Battery Energy Storage Systems for Primary Frequency Regulation in Island Power Systems2020
- Power system responses to geomagnetic disturbances recognized using phasor measurement recordingsInternational Journal of Electrical Power & Energy Systems, 2019
- Modified method for transformer magnetizing characteristic computation and point‐on‐wave control switching for inrush current mitigationInternational Journal of Circuit Theory and Applications, 2019
- Impacts of grounding and winding configurations on voltage harmonics in 3φ power transformers2018
- IEEE Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances2015
- Impacts of grounding configurations on responses of ground protective relays for DFIG-based WECSs2014
- Impacts of Hysteresis and Magnetic Couplings on the Stability Domain of Ferroresonance in Asymmetric Three-Phase Three-Leg TransformersIEEE Transactions on Energy Conversion, 2010
- Testing of a Wavelet-Packet-Transform-Based Differential Protection for Resistance-Grounded Three-Phase TransformersIEEE Transactions on Industry Applications, 2010
- Real-Time Testing of a WPT-Based Protection Algorithm for Three-Phase Power TransformersIEEE Transactions on Industry Applications, 2005