Online Diagnosis of Short-Circuit Faults of Permanent Magnet Synchronous Generator by Short-Time Analysis of the Three Phase Amplitude-Phase Signal Based on Analytical Modeling
- 26 February 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 10029-10042
Abstract
Turn-to-turn short circuit (TTSC) fault is one of the most common faults in electric machines and may destroy coil insulation and demagnetize the magnets. In addition to the TTSC fault, this paper also introduces and analyzes the phase-to-phase short circuit (PPSC) fault, which can have even more destructive effects than the TTSC fault. The analytical equivalent magnetic network (EMN) method is used to accurately model the healthy and faulty machine with a shorter processing time than the finite element method (FEM). The output current of the generator in the αβ frame is employed to detect the faults. The mathematical equations demonstrate the change in amplitude and phase of the signals under fault conditions. Therefore, the short-time analysis of the amplitude-phase signal (ST-APS) method is presented, and the fault index is obtained by extracting real-time amplitude and phase. In addition, the proposed method separates TTSC and PPSC faults. Finally, FEM and EMN modeling results are compared with the experimental results for the prototype permanent magnet synchronous machine. The results showed that the proposed EMN method combined with ST-APS achieves a high accuracy and enables fault detection in various stages, regardless of changes in generator speed or transient conditions. Furthermore, the proposed fault detection method is unaffected by various non-linear loads or winding configurations, ensuring high reliability.Keywords
This publication has 33 references indexed in Scilit:
- Digital twin-driven intelligent assessment of gear surface degradationMechanical Systems and Signal Processing, 2022
- Analysis and detection of turn‐to‐turn short circuit fault in a permanent magnet Vernier generator based on modified winding functionIET Electric Power Applications, 2021
- Improved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSMIET Electric Power Applications, 2019
- Turn‐to‐turn short circuit of motor stator fault diagnosis in continuous state based on deep auto‐encoderIET Electric Power Applications, 2019
- A Wavelet-Based Fault Diagnosis Approach for Permanent Magnet Synchronous MotorsIEEE Transactions on Energy Conversion, 2018
- Magnetic‐equivalent‐circuit approach for inter‐turn and demagnetisation faults analysis in surface mounted permanent‐magnet synchronous machines using pole specific search‐coil techniqueIET Electric Power Applications, 2018
- Interturn Short Fault Diagnosis in a PMSM by Voltage and Current Residual Analysis With the Faulty Winding ModelIEEE Transactions on Energy Conversion, 2017
- A novel method for permanent magnet demagnetization fault detection and treatment in permanent magnet synchronous machines2010
- Moving towards a more electric aircraftIEEE Aerospace and Electronic Systems Magazine, 2007
- Partitioning of synchronous machine windings for internal fault analysisIEEE Transactions on Energy Conversion, 2000