The Agfa Mayneord lecture: MRI of short and ultrashortT2andT2* components of tissues, fluids and materials using clinical systems
Author:
- 1 December 2011
- journal article
- review article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 84 (1008) , 1067-1082
Abstract
A variety of techniques are now available to directly or indirectly detect signal from tissues, fluids and materials that have short, ultrashort or supershort T₂ or T₂* components. There are also methods of developing image contrast between tissues and fluids in the short T₂ or T₂* range that can provide visualisation of anatomy, which has not been previously seen with MRI. Magnetisation transfer methods can now be applied to previously invisible tissues, providing indirect access to supershort T₂ components. Particular methods have been developed to target susceptibility effects and quantify them after correcting for anatomical distortion. Specific methods have also been developed to image the effects of magnetic iron oxide particles with positive contrast. Major advances have been made in techniques designed to correct for loss of signal and gross image distortion near metal. These methods are likely to substantially increase the range of application for MRI.Keywords
This publication has 132 references indexed in Scilit:
- Ultra‐short echo time (UTE) MR imaging of the lung: Comparison between normal and emphysematous lungs in mutant miceJournal of Magnetic Resonance Imaging, 2010
- k‐space water‐fat decomposition with T2* estimation and multifrequency fat spectrum modeling for ultrashort echo time imagingJournal of Magnetic Resonance Imaging, 2010
- Accelerated slice encoding for metal artifact correctionJournal of Magnetic Resonance Imaging, 2010
- Consistency of signal intensity and T2* in frozen ex vivo heart muscle, kidney, and liver tissueJournal of Magnetic Resonance Imaging, 2010
- Rapid isotropic 3D‐sodium MRI of the knee joint in vivo at 7TJournal of Magnetic Resonance Imaging, 2009
- Improved half RF slice selectivity in the presence of eddy currents with out‐of‐slice saturationMagnetic Resonance in Medicine, 2009
- Ultrashort T relaxometry for quantitation of highly concentrated superparamagnetic iron oxide (SPIO) nanoparticle labeled cellsMagnetic Resonance in Medicine, 2009
- In vivo serial evaluation of superparamagnetic iron‐oxide labeled stem cells by off‐resonance positive contrastMagnetic Resonance in Medicine, 2008
- Susceptibility gradient mapping (SGM): A new postprocessing method for positive contrast generation applied to superparamagnetic iron oxide particle (SPIO)‐labeled cellsMagnetic Resonance in Medicine, 2008
- 3D radial projection technique with ultrashort echo times for sodium MRI: Clinical applications in human brain and skeletal muscleMagnetic Resonance in Medicine, 2006