Graeme M. Bydder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Graeme M. Bydder has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Eric Y. Chang
Department of Radiology, San Diego Medical Center, University of California, San Diego, USA
5 shared publications - Jiang Du
Department of Radiology, University of California San Diego, La Jolla, USA
5 shared publications - Matthew D. Robson
Oxford Centre for Clinical Magnetic Resonance Research, Radcliffe Department of Medicine University of Oxford Oxford UK
5 shared publications - Peter D. Gatehouse
Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, United Kingdom
5 shared publications - Basant K. Puri
Cambridge Advanced Research, Cambridge CB21, UK
4 shared publications Angela Oatridge
Robert Steiner Magnetic Resonance Unit, Imaging Sciences Department, Faculty of Medicine, Imperial College, Hammersmith Hospital Campus, London W12 0HS, England, UK
3 shared publications
Latest Publications
- Open Access
- 19 December 2025
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 34 (7) , 1105-1116
Comprehensive zonal assessment of meniscal degeneration using quantitative UTE MRI
- 19 December 2025
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 34 (7) , 1105-1116
Open AccessComprehensive zonal assessment of meniscal degeneration using quantitative UTE MRI
- 31 October 2022
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 9 (4) , 041303
Making the invisible visible—ultrashort echo time magnetic resonance imaging: Technical developments and applications
Magnetic resonance imaging (MRI) uses a large magnetic field and radio waves to generate images of tissues in the body. Conventional MRI techniques have been developed to image and quantify tissues and fluids with long transverse relaxation times (T2s), such as muscle, cartilage, liver, white matter, gray matter, spinal cord, and cerebrospinal fluid. However, the body also contains many tissues and tissue components such as the osteochondral junction, menisci, ligaments, tendons, bone, lung parenchyma, and myelin, which have short or ultrashort T2s. After radio frequency excitation, their transverse magnetizations typically decay to zero or near zero before the receiving mode is enabled for spatial encoding with conventional MR imaging. As a result, these tissues appear dark, and their MR properties are inaccessible. However, when ultrashort echo times (UTEs) are used, signals can be detected from these tissues before they decay to zero. This review summarizes recent technical developments in UTE MRI of tissues with short and ultrashort T2 relaxation times. A series of UTE MRI techniques for high-resolution morphological and quantitative imaging of these short-T2 tissues are discussed. Applications of UTE imaging in the musculoskeletal, nervous, respiratory, gastrointestinal, and cardiovascular systems of the body are included.
- 31 October 2022
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 9 (4) , 041303
Making the invisible visible—ultrashort echo time magnetic resonance imaging: Technical developments and applications
Magnetic resonance imaging (MRI) uses a large magnetic field and radio waves to generate images of tissues in the body. Conventional MRI techniques have been developed to image and quantify tissues and fluids with long transverse relaxation times (T2s), such as muscle, cartilage, liver, white matter, gray matter, spinal cord, and cerebrospinal fluid. However, the body also contains many tissues and tissue components such as the osteochondral junction, menisci, ligaments, tendons, bone, lung parenchyma, and myelin, which have short or ultrashort T2s. After radio frequency excitation, their transverse magnetizations typically decay to zero or near zero before the receiving mode is enabled for spatial encoding with conventional MR imaging. As a result, these tissues appear dark, and their MR properties are inaccessible. However, when ultrashort echo times (UTEs) are used, signals can be detected from these tissues before they decay to zero. This review summarizes recent technical developments in UTE MRI of tissues with short and ultrashort T2 relaxation times. A series of UTE MRI techniques for high-resolution morphological and quantitative imaging of these short-T2 tissues are discussed. Applications of UTE imaging in the musculoskeletal, nervous, respiratory, gastrointestinal, and cardiovascular systems of the body are included.
- 1 June 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 299 (3) , 673-674
Brain Atrophy Is a Better Biomarker than Susceptibility for Evaluating Clinical Severity in Wilson Disease
- 1 June 2021
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 299 (3) , 673-674
Brain Atrophy Is a Better Biomarker than Susceptibility for Evaluating Clinical Severity in Wilson Disease
- Open Access
- 18 February 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (5) , 868-874
Inversion Recovery Ultrashort TE MR Imaging of Myelin is Significantly Correlated with Disability in Patients with Multiple Sclerosis
Circulating extracellular vesicles (EVs) present in the bodily fluids of patients with cancer may provide non-invasive access to the tumor tissue. Yet, the transcriptomic lineage of tumor-derived EVs before and after tumor-resection remains poorly understood. Here, we established 60 total small RNA-sequencing profiles from 17 aggressive prostate cancer (PCa) patient’s tumor and adjacent normal tissue, and EVs isolated from urine, serum, and cancer cell culture media. We interrogated the key satellite alteration in tumor-derived EVs and found that resection of tumor prostate tissue leads to differential expression of reactive oxygen species (ROS), P53 pathways, inflammatory/cytokines, oncogenes, and tumor suppressor genes in the EV nanosatellites. Furthermore, we provide a set of novel EV-specific RNA signature, which are present in cancer but are nonexistent in post-resection patients with undetectable cancer. Finally, using a de novo RNAseq assembly followed by characterization of the small RNA landscape, we found novel small RNA clusters (smRCs) in the EVs, which reside in the unannotated regions. Novel smRCs were orthogonally validated for their differential expression in the ‘biomarker discovery’ cohort using RT-qPCR. We demonstrate that circulating tumor EVs provide a glimpse of the tumor tissue biology, resolving a major bottleneck in the current liquid biopsy efforts. Secretory vesicles appear to be playing a key role in non-canonical Wnt signaling and miRNA pathways, similar to the circulating tumor cells (CTCs), hence, we propose that such vesicles be called circulating tumor extracellular vesicles (CTEVs).
- 18 February 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 42 (5) , 868-874
Open AccessInversion Recovery Ultrashort TE MR Imaging of Myelin is Significantly Correlated with Disability in Patients with Multiple Sclerosis
Circulating extracellular vesicles (EVs) present in the bodily fluids of patients with cancer may provide non-invasive access to the tumor tissue. Yet, the transcriptomic lineage of tumor-derived EVs before and after tumor-resection remains poorly understood. Here, we established 60 total small RNA-sequencing profiles from 17 aggressive prostate cancer (PCa) patient’s tumor and adjacent normal tissue, and EVs isolated from urine, serum, and cancer cell culture media. We interrogated the key satellite alteration in tumor-derived EVs and found that resection of tumor prostate tissue leads to differential expression of reactive oxygen species (ROS), P53 pathways, inflammatory/cytokines, oncogenes, and tumor suppressor genes in the EV nanosatellites. Furthermore, we provide a set of novel EV-specific RNA signature, which are present in cancer but are nonexistent in post-resection patients with undetectable cancer. Finally, using a de novo RNAseq assembly followed by characterization of the small RNA landscape, we found novel small RNA clusters (smRCs) in the EVs, which reside in the unannotated regions. Novel smRCs were orthogonally validated for their differential expression in the ‘biomarker discovery’ cohort using RT-qPCR. We demonstrate that circulating tumor EVs provide a glimpse of the tumor tissue biology, resolving a major bottleneck in the current liquid biopsy efforts. Secretory vesicles appear to be playing a key role in non-canonical Wnt signaling and miRNA pathways, similar to the circulating tumor cells (CTCs), hence, we propose that such vesicles be called circulating tumor extracellular vesicles (CTEVs).
- 11 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 297 (2) , 392-404
Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE) MRI Sequence in Multiple Sclerosis
A new three-dimensional short repetition time adiabatic inversion recovery–prepared ultrashort echo time sequence provided selective imaging of brain myelin with water signals efficiently suppresse... Background Water signal contamination is a major challenge for direct ultrashort echo time (UTE) imaging of myelin in vivo because water contributes most of the signals detected in white matter. Pu...
- 11 August 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 297 (2) , 392-404
Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE) MRI Sequence in Multiple Sclerosis
A new three-dimensional short repetition time adiabatic inversion recovery–prepared ultrashort echo time sequence provided selective imaging of brain myelin with water signals efficiently suppresse... Background Water signal contamination is a major challenge for direct ultrashort echo time (UTE) imaging of myelin in vivo because water contributes most of the signals detected in white matter. Pu...
- 15 May 2020
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 40 (4) , 1107-1124
High-Resolution MRI of the First Metatarsophalangeal Joint: Gross Anatomy and Injury Characterization
The first metatarsophalangeal joint is a complex of supporting structures that is vital to the biomechanics of the foot, and forced hyperextension of the first metatarsophalangeal joint known as tu... The first metatarsophalangeal joint (MTPJ) is vital to the biomechanics of the foot and supports a weight up to eight times heavier than the body during athletic activities. The first MTPJ comprise...
- 15 May 2020
- Published by Radiological Society of North America (RSNA) in RadioGraphics
- Vol. 40 (4) , 1107-1124
High-Resolution MRI of the First Metatarsophalangeal Joint: Gross Anatomy and Injury Characterization
The first metatarsophalangeal joint is a complex of supporting structures that is vital to the biomechanics of the foot, and forced hyperextension of the first metatarsophalangeal joint known as tu... The first metatarsophalangeal joint (MTPJ) is vital to the biomechanics of the foot and supports a weight up to eight times heavier than the body during athletic activities. The first MTPJ comprise...
- Open Access
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (6) , 936-944
High-Resolution Qualitative and Quantitative Magnetic Resonance Evaluation of the Glenoid Labrum
Objective This study aimed to implement qualitative and quantitative magnetic resonance sequences for the evaluation of labral pathology. Methods Six glenoid labra were dissected, and the anterior and posterior portions were divided into normal, mildly degenerated, or severely degenerated groups using gross and magnetic resonance findings. Qualitative evaluation was performed using T1-weighted, proton density-weighted, spoiled gradient echo and ultrashort echo time (UTE) sequences. Quantitative evaluation included T2 and T1rho measurements as well as T1, T2*, and T1rho measurements acquired with UTE techniques. Results Spoiled gradient echo and UTE sequences best demonstrated labral fiber structure. Degenerated labra had a tendency toward decreased T1 values, increased T2/T2* values, and increased T1rho values. T2* values obtained with the UTE sequence allowed for delineation among normal, mildly degenerated, and severely degenerated groups (P < 0.001). Conclusions Quantitative T2* measurements acquired with the UTE technique are useful for distinguishing among normal, mildly degenerated, and severely degenerated labra.
- 1 January 2015
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 39 (6) , 936-944
Open AccessHigh-Resolution Qualitative and Quantitative Magnetic Resonance Evaluation of the Glenoid Labrum
Objective This study aimed to implement qualitative and quantitative magnetic resonance sequences for the evaluation of labral pathology. Methods Six glenoid labra were dissected, and the anterior and posterior portions were divided into normal, mildly degenerated, or severely degenerated groups using gross and magnetic resonance findings. Qualitative evaluation was performed using T1-weighted, proton density-weighted, spoiled gradient echo and ultrashort echo time (UTE) sequences. Quantitative evaluation included T2 and T1rho measurements as well as T1, T2*, and T1rho measurements acquired with UTE techniques. Results Spoiled gradient echo and UTE sequences best demonstrated labral fiber structure. Degenerated labra had a tendency toward decreased T1 values, increased T2/T2* values, and increased T1rho values. T2* values obtained with the UTE sequence allowed for delineation among normal, mildly degenerated, and severely degenerated groups (P < 0.001). Conclusions Quantitative T2* measurements acquired with the UTE technique are useful for distinguishing among normal, mildly degenerated, and severely degenerated labra.
- 24 June 2014
- Published by Springer Nature in Skeletal Radiology
- Vol. 43 (10) , 1395-1402
Morphologic characterization of meniscal root ligaments in the human knee with magnetic resonance microscopy at 11.7 and 3 T
Objective To determine the feasibility of using MR microscopy to characterize the root ligaments of the human knee at both ultra-high-field (11.7 T) and high-field (3 T) strengths. Materials and methods Seven fresh cadaveric knees were used for this study. Six specimens were imaged at 11.7 T and one specimen at 3 T using isotropic or near-isotropic voxels. Histologic correlation was performed on the posteromedial root ligament of one specimen. Meniscal root ligament shape, signal intensity, and ultrastructure were characterized. Results High-resolution, high-contrast volumetric images were generated from both MR systems. Meniscal root ligaments were predominantly oval in shape. Increased signal intensity was most evident at the posteromedial and posterolateral root ligaments. On the specimen that underwent histologic preparation, increased signal intensity corresponded to regions of enthesis fibrocartilage. Collagen fascicles were continuous between the menisci and root ligaments. Predominantly horizontal meniscal radial tie fibers continued into the root ligaments as vertical endoligaments. Conclusion MR microscopy can be used to characterize and delineate the distinct ultrastructure of the root ligaments on both ultra-high-field- and high-field-strength MR systems.
- 24 June 2014
- Published by Springer Nature in Skeletal Radiology
- Vol. 43 (10) , 1395-1402
Morphologic characterization of meniscal root ligaments in the human knee with magnetic resonance microscopy at 11.7 and 3 T
Objective To determine the feasibility of using MR microscopy to characterize the root ligaments of the human knee at both ultra-high-field (11.7 T) and high-field (3 T) strengths. Materials and methods Seven fresh cadaveric knees were used for this study. Six specimens were imaged at 11.7 T and one specimen at 3 T using isotropic or near-isotropic voxels. Histologic correlation was performed on the posteromedial root ligament of one specimen. Meniscal root ligament shape, signal intensity, and ultrastructure were characterized. Results High-resolution, high-contrast volumetric images were generated from both MR systems. Meniscal root ligaments were predominantly oval in shape. Increased signal intensity was most evident at the posteromedial and posterolateral root ligaments. On the specimen that underwent histologic preparation, increased signal intensity corresponded to regions of enthesis fibrocartilage. Collagen fascicles were continuous between the menisci and root ligaments. Predominantly horizontal meniscal radial tie fibers continued into the root ligaments as vertical endoligaments. Conclusion MR microscopy can be used to characterize and delineate the distinct ultrastructure of the root ligaments on both ultra-high-field- and high-field-strength MR systems.
- 1 December 2011
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 84 (1008) , 1067-1082
The Agfa Mayneord lecture: MRI of short and ultrashortT2andT2* components of tissues, fluids and materials using clinical systems
A variety of techniques are now available to directly or indirectly detect signal from tissues, fluids and materials that have short, ultrashort or supershort T₂ or T₂* components. There are also methods of developing image contrast between tissues and fluids in the short T₂ or T₂* range that can provide visualisation of anatomy, which has not been previously seen with MRI. Magnetisation transfer methods can now be applied to previously invisible tissues, providing indirect access to supershort T₂ components. Particular methods have been developed to target susceptibility effects and quantify them after correcting for anatomical distortion. Specific methods have also been developed to image the effects of magnetic iron oxide particles with positive contrast. Major advances have been made in techniques designed to correct for loss of signal and gross image distortion near metal. These methods are likely to substantially increase the range of application for MRI.
- 1 December 2011
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 84 (1008) , 1067-1082
The Agfa Mayneord lecture: MRI of short and ultrashortT2andT2* components of tissues, fluids and materials using clinical systems
A variety of techniques are now available to directly or indirectly detect signal from tissues, fluids and materials that have short, ultrashort or supershort T₂ or T₂* components. There are also methods of developing image contrast between tissues and fluids in the short T₂ or T₂* range that can provide visualisation of anatomy, which has not been previously seen with MRI. Magnetisation transfer methods can now be applied to previously invisible tissues, providing indirect access to supershort T₂ components. Particular methods have been developed to target susceptibility effects and quantify them after correcting for anatomical distortion. Specific methods have also been developed to image the effects of magnetic iron oxide particles with positive contrast. Major advances have been made in techniques designed to correct for loss of signal and gross image distortion near metal. These methods are likely to substantially increase the range of application for MRI.
- 22 October 2008
- Published by Springer Nature in Skeletal Radiology
- Vol. 38 (3) , 201-205
Magnetic resonance imaging of short T2 relaxation components in the musculoskeletal system
- 22 October 2008
- Published by Springer Nature in Skeletal Radiology
- Vol. 38 (3) , 201-205
Magnetic resonance imaging of short T2 relaxation components in the musculoskeletal system