Abstract
We propose a new deep learning based approach to provide more accurate whole-body PET/MRI attenuation correction in comparison to the Dixon-based four-segment method. We use activity and attenuation maps estimated using the maximum likelihood reconstruction of activity and attenuation (MLAA) algorithm as inputs to convolutional neural network (CNN) to learn a CT-derived attenuation map. Methods: The whole-body 18F-FDG PET/CT scan data of 100 cancer patients (38 males and 62 females, age = 57.3 ± 14.1 years) was retrospectively used for training and testing the CNN. A modified U-net was trained to predict a CT-derived μ-map (μ-CT) from the MLAA-generated activity distribution (λ-MLAA) and μ-map (μ-MLAA). One point three million patches derived from sixty patients’ data were used for training the CNN, data of 20 others were used as a validation set to prevent overfitting, and the data of the other 20 were used as a test set for the CNN performance analysis. The attenuation maps generated using the proposed method (μ-CNN), μ-MLAA, and four-segment method (μ-segment) were compared with the μ-CT, a ground truth. We also compared the voxel-wise correlation between the activity images reconstructed using OSEM with the μ-maps, and the standard uptake values of primary and metastatic bone lesions obtained by drawing regions of interest on the activity images. Results: The CNN generates less noisy attenuation maps and achieves better bone identification than MLAA. The average Dice similarity coefficient for bone regions between μ-CNN and μ-CT was 0.77, which was significantly higher than that between μ-MLAA and μ-CT (0.36). Also, the CNN result showed the best pixel-by-pixel correlation with the CT-based results and remarkably reduced differences of activity maps in comparison to CT-based attenuation correction. Conclusion: The proposed deep neural network produced a more reliable attenuation map for 511 keV photons than the four-segment method currently used in whole-body PET/MRI studies.Keywords
This publication has 37 references indexed in Scilit:
- Accurate PET/MR Quantification Using Time of Flight MLAA Image ReconstructionMolecular Imaging and Biology, 2014
- Comparison of Segmentation-Based Attenuation Correction Methods for PET/MRI: Evaluation of Bone and Liver Standardized Uptake Value with Oncologic PET/CT DataJournal of Nuclear Medicine, 2012
- Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRIMagnetic Resonance Materials in Physics, Biology and Medicine, 2012
- Variable Lung Density Consideration in Attenuation Correction of Whole-Body PET/MRIJournal of Nuclear Medicine, 2012
- Initial Results of Simultaneous PET/MRI Experiments with an MRI-Compatible Silicon Photomultiplier PET ScannerJournal of Nuclear Medicine, 2012
- Time-of-flight PET data determine the attenuation sinogram up to a constantPhysics in Medicine & Biology, 2012
- MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time SequencesJournal of Nuclear Medicine, 2010
- Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT DataJournal of Nuclear Medicine, 2009
- Towards quantitative PET/MRI: a review of MR-based attenuation correction techniquesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2008
- Simultaneous PET-MRI: a new approach for functional and morphological imagingNature Medicine, 2008