Outcome study of the Pipeline Vantage Embolization Device (second version) in unruptured (and ruptured) aneurysms (PEDVU(R) study)
Authors:
- Thomas C BoothTBThomas C Booth
- Ahmed BassiounyABAhmed Bassiouny
- Jeremy LynchJLJeremy Lynch
- Hemant SonwalkarHSHemant Sonwalkar
- Aaron BleakleyABAaron Bleakley
- Ahmed IqbalAIAhmed Iqbal
- Thais MinettTMThais Minett
- Jonathon BuwanabalaJBJonathon Buwanabala
- Ana Paula NarataANAna Paula Narata
- Tufail PatankarTPTufail Patankar
- Fathallah Ismail IslimFIFathallah Ismail Islim
- Naga KandasamyNKNaga Kandasamy
Open Access
- 9 December 2023
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 16 (11) , 1136-1144
Abstract
Background The Pipeline Vantage Embolization Device (PEDV) is the fourth-generation pipeline flow diverter for intracranial aneurysm treatment. There are no outcome studies for the second PEDV version. We aimed to evaluate safety and efficacy outcomes. Primary and secondary objectives were to determine outcomes for unruptured and ruptured cohorts, respectively. Methods In this multicenter retrospective and prospective study, we analyzed outcome data from eight centers using core laboratory assessments. We determined 30-day and ≥3-month mortality and morbidity rates, and 6- and 18-month radiographic aneurysm occlusion rates for procedures performed during the period July 2021–March 2023. Results We included 121 consecutive patients with 131 aneurysms. The adequate occlusion rate for the unruptured cohort at short-term and medium-term follow up, and also for the ruptured cohort at short-term follow up, was >90%. Two aneurysms (1.5%) underwent retreatment. When mortality attributed to a palliative case in the unruptured cohort, or subarachnoid hemorrhage in the ruptured cohort, was excluded then the overall major adverse event rate in respective cohorts was 7.5% and 23.5%, with 0% mortality rates for each. When all event causes were included on an intention-to-treat basis, the major adverse event rates in respective cohorts were 8.3% and 40.9%, with 0.9% and 22.7% mortality rates. Conclusions For unruptured aneurysm treatment, the second PEDV version appears to have a superior efficacy and similar safety profile to previous-generation PEDs. These are acceptable outcomes in this pragmatic and non-industry-sponsored study. Analysis of ruptured aneurysm outcomes is limited by cohort size. Further prospective studies, particularly for ruptured aneurysms, are needed.Keywords
Funding Information
- Wellcome Trust (WT 203148/Z/16/Z)
- Egyptian Cultural and Educational Bureau (NMJ3/20)
This publication has 23 references indexed in Scilit:
- Aneurysm Study of Pipeline in an Observational Registry (ASPIRe)Interventional Neurology, 2016
- International Retrospective Study of the Pipeline Embolization Device: A Multicenter Aneurysm Treatment StudyAmerican Journal of Neuroradiology, 2014
- New Pipeline Flex device: initial experience and technical nuancesJournal of NeuroInterventional Surgery, 2014
- Utilization of Pipeline embolization device for treatment of ruptured intracranial aneurysms: US multicenter experienceJournal of NeuroInterventional Surgery, 2014
- An update to the Raymond–Roy Occlusion Classification of intracranial aneurysms treated with coil embolizationJournal of NeuroInterventional Surgery, 2014
- Toward an Endovascular Internal Carotid Artery Classification SystemAmerican Journal of Neuroradiology, 2013
- The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms TrialAmerican Journal of Neuroradiology, 2010
- A Novel Grading Scale for the Angiographic Assessment of Intracranial Aneurysms Treated Using Flow Diverting StentsInterventional Neuroradiology, 2010
- Fusiform aneurysm of the vertebrobasilar arterial system.Stroke, 1989
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977