Would an Anatomically Shaped Lumbar Interbody Cage Provide Better Stability? An In Vitro Cadaveric Biomechanical Evaluation
Authors:
- Hassan SerhanHSHassan Serhan
- Leonard I. VoronovLVLeonard I. Voronov
- Gerard CarandangGCGerard Carandang
- Robert M. HaveyRHRobert M. Havey
- Alexander J. GhanayemAGAlexander J. Ghanayem
- Avinash G. PatwardhanAPAvinash G. Patwardhan
- 1 December 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 25 (8) , E240-E244
Abstract
A biomechanical cadaveric study of lumbar spine segments. To compare the immediate stability provided by parallel-shaped and anatomically shaped carbon fiber interbody fusion I/F cages in posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF) constructs with posterior pedicle screw instrumentation. Few biomechanical data are available on the anatomically shaped cages in PLIF and TLIF constructs. Twenty human lumbar segments were tested in flexion-extension (FE) (8 N m flexion, 6 N m extension), lateral bending (LB) (± 6 N m), and torsional loading (± 5 N m). Each segment was tested in the intact state and after insertion of interbody cages in one of 3 constructs: PLIF with 2 parallel-shaped or anatomically shaped cages and TLIF with 1 anatomically shaped cage. All cages received supplementary pedicle screw fixation. The range-of-motion (ROM) values after cage insertion and posterior fixation were compared with the intact specimen values using analysis of variance and multiple comparisons with Bonferroni correction. All constructs significantly reduced segmental motion relative to intact (P < 0.001). The motion reductions in FE, LB, and axial rotation were 85 ± 15%, 83 ± 18%, and 67 ± 6.8% for the PLIF construct using parallel cages, 79 ± 5.5%, 87 ± 10%, and 66 ± 20% for PLIF using anatomically shaped cages, and 90 ± 6.8%, 87 ± 12%, and 77 ± 22% for TLIF with an anatomically shaped cage. In FE and LB, the reductions in the ROM caused between the 3 constructs were equivalent (P > 0.05). In axial rotation, the TLIF cage provided significantly greater limitation in the ROM compared with the parallel-shaped PLIF cage (P = 0.01). The parallel-shaped and anatomically shaped I/F cages provided similar stability in a PLIF construct. The greater stability of the TLIF construct was likely due to a more anterior placement of the TLIF cage and preservation of the contralateral facet joint.Keywords
This publication has 10 references indexed in Scilit:
- Posterior Lumbar Interbody FusionJournal of the American Academy of Orthopaedic Surgeons, 2008
- Comparison of Sagittal Contour and Posterior Disc Height Following Interbody FusionJournal of Spinal Disorders & Techniques, 2005
- The Lumbar I/F Cage for posterior lumbar interbody fusion with the Variable Screw Placement System: 10-year results of a Food and Drug Administration clinical trialThe Spine Journal, 2004
- Lumbar interbody fusion: state-of-the-art technical advancesJournal of Neurosurgery: Spine, 2004
- Gamma knife radiosurgery for brainstem arteriovenous malformations: preliminary resultsJournal of Neurosurgery, 2000
- Biomechanics of stand-alone cages and cages in combination with posterior fixation: a literature reviewEuropean Spine Journal, 2000
- The Biomechanical Significance of Anterior Column Support in a Simulated Single-Level Spinal FusionJournal of Spinal Disorders, 2000
- Biomechanical Evaluation of Posterior and Anterior Lumbar Interbody Fusion TechniquesJournal of Spinal Disorders, 1998
- Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density.The Journal of Bone and Joint Surgery. British volume, 1998
- Interbody cage stabilisation in the lumbar spineThe Journal of Bone and Joint Surgery. British volume, 1998