HSHassan Serhan

Hassan Serhan

*This is an algorithmically generated author record based on publicly available information.

Hassan Serhan has a total of 171 co-authors. Here are the top co-authors by number of shared publications:

  • Nianbin Hu

    The Orthopaedic Spinal Research Laboratory, St. Joseph Medical Center, Towson

    5 shared publications
  • Vijay Kumar Goel

    Engineering Center for Orthopedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, University of Toledo, Toledo, OH, USA

    5 shared publications
  • Andrew P. Dooris

    Big Sky Neuroscience and Spine Institute, Butte, Montana and

    3 shared publications
  • Ashok Biyani

    Engineering Center for Orthopaedic Research Excellence (E-CORE), Departments of Bioengineering and Orthopaedic Surgery, 5046 NI, MS 303, Colleges of Engineering and Medicine, University of Toledo, Toledo, USA

    3 shared publications
  • Bryan W. Cunningham

    The Orthopaedic Spinal Research Laboratory, St. Joseph Medical Center, Towson

    3 shared publications
  • James C. Torner

    3 shared publications

Latest Publications

  • Spinal Balance/Alignment—Clinical Relevance and Biomechanics

    by Anoli A. Shah, Justin V. C. Lemans, Joseph Zavatsky, Aakash Agarwal, Moyo C. Kruyt, Koji Matsumoto, Hassan Serhan, Anand K. Agarwal, Vijay K. Goel

    In the anatomy of a normal spine, due to the curvatures in various regions, the C7 plumb line (C7PL) passes through the sacrum so that the head is centered over the pelvic-ball and socket hip and ankle joints. A failure to recognize malalignment in the sagittal plane can affect the patient's activity as well as social interaction due to deficient forward gaze. The sagittal balance configuration leads to the body undertaking the least muscular activities as possible necessary to maintain spinal balance. Global sagittal imbalance is energy consuming and often results in painful compensatory mechanisms that in turn negatively influence the patient's quality of life, self-image, and social interaction due to inability to maintain a horizontal gaze. Deformity, scoliosis, kyphosis, trauma, and/or surgery are some ways that this optimal configuration can be disturbed, thus requiring higher muscular activity to maintain posture and balance. Several parameters such as the thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), sacral slope (SS), and hip and leg positions influence the sagittal balance and thus the optimal configuration of spinal alignment. This review examines the clinical and biomechanical aspects of spinal imbalance, and the biomechanics of spinal balance as dictated by deformities—ankylosing spondylitis (AS), scoliosis and kyphosis; surgical corrections—pedicle subtraction osteotomies (PSO), long segment stabilizations, and consequent postural complications like proximal and distal junctional kyphosis. The study of the biomechanics involved in spinal imbalance is relatively new and thus the literature is rather sparse. This review suggests several potential research topics in the area of spinal biomechanics.


  • Time Savings and Related Economic Benefits of Suction-Curette Device for Transforaminal Lumbar Interbody Fusion Discectomy

    by Fred Mo, Philip Yuan, Ali Araghi, Hassan Serhan

    Background: Performing an adequate transforaminal lumbar interbody fusion (TLIF) discectomy requires numerous instrument passes, increasing surgical time and the risk of complications. The purpose of this study was to evaluate the efficacy and efficiency of discectomy and endplate preparation during TLIF using traditional manual instrumentation versus a novel suction discectomy curette. The direct economic benefit with use of the suction discectomy curette is calculated. Methods: Three experienced, spine-fellowship-trained surgeons performed TLIF discectomies on 3 cadaveric specimens from T12 to S1 using either traditional manual discectomy instruments or CONCORD Clear (Xtool) devices supplemented with manual discectomy instruments. For each level in which a discectomy was performed, the following were measured: elapsed time, number of instrument passes and the number of instrument exchanges, and estimated tissue volume. Results: Transforaminal lumbar interbody fusion discectomy times improved on average 11:32 minutes per level, which equates to an estimated procedural time savings of 15:85 minutes, using 1.4 levels per TLIF, the average number of levels in a large series. Usage of the CONCORD Clear significantly reduced instrument passes compared to traditional, with a mean of 62.0 for traditional versus 7.1 for CONCORD Clear, an 8.7-fold improvement. Instrument exchanges showed a 5.9-fold improvement, with means of 26.8 and 4.6, respectively. Wet discectomy tissue volume was measured for each discectomy, with a mean of 5.4 cc for traditional versus 12.9 cc for CONCORD Clear, a 2.4-fold improvement. Conclusions: This study estimates that, in a typical TLIF procedure, over 15 minutes should be saved by using the CONCORD Clear l device (a quarter of the time of a traditional discectomy), and by considering the direct cost-benefit associated with this time savings as well as reduced sterilization costs, it is estimated that a hospital could save approximately $1300 in operating room time and sterilization cost with the use of the CONCORD Clear device in a typical 1-level TLIF procedure.


  • A Comparative Biomechanical Analysis of Stand Alone Versus Facet Screw and Pedicle Screw Augmented Lateral Interbody Arthrodesis

    by Ryan M. Kretzer, Camilo Molina, Nianbin Hu, Hidemasa Umekoji, Ali A. Baaj, Hassan Serhan, Bryan W. Cunningham

    Cadaveric biomechanical study. To investigate the kinematic response of a stand-alone lateral lumbar interbody cage compared with supplemental posterior fixation with either facet or pedicle screws after lateral discectomy. Lateral interbody fusion is a promising minimally invasive fixation technique for lumbar interbody arthrodesis. The biomechanical stability of stand-alone cage placement compared with supplemental posterior fixation with either facet or bilateral pedicle screws remains unclear. A 6-degree of freedom spine simulator was used to test flexibility in 7 human cadaveric specimens. Flexion-extension, lateral-bending, and axial-rotation were tested in the intact condition, followed by destabilization through a lateral discectomy at L2-L3 and L4-L5. Specimens were then reconstructed at both operative segments in the following sequence: (1) lateral interbody cage placement; (2) either Discovery facet screws or the Viper F2 system using a transfacet-pedicular trajectory randomized to L2-L3 or L4-L5; and (3) removal of facet screw fixation followed by placement of bilateral pedicle screw instrumentation. Acute range of motion (ROM) was quantified and analyzed. All 4 reconstruction groups, including stand-alone interbody cage placement, bilateral Discovery facet screws, the Viper F2 system, and bilateral pedicle screw-rod stabilization, resulted in a significant decrease in acute ROM in all loading modes tested (P0.05). Although not statistically significant, the Viper F2 system resulted in greatest reduction of acute ROM in both flexion-extension and axial rotation versus all other treatments (P>0.05). Stand-alone interbody cage placement results in a significant reduction in acute ROM at the operative segment in the absence of posterior supplemental fixation. If added fixation is desired, facet screw placement, including the Viper F2 facet screw system using an integrated compression washer and transfacet-pedicular trajectory, provides similar acute stability to the spinal segment compared with traditional bilateral pedicle screw fixation in the setting of lateral interbody cage deployment.


  • Open Access

    Reduced Rate of Proximal Junctional Fractures above Long-Segment Instrumented Constructs Utilizing a Tapered Dose of Bone Cement for Prophylactic Vertebroplasty, A Biomechanical Investigation

    by Joseph Zavatsky, Anoli Shah, Robert McGuire, Hassan Serhan, Amey Kelkar, Manoj Kodigudla, Aakash Agarwal, David Briski, Vijay Goel

    Introduction: PJK is a well-described post-operative complication associated with long instrumented fusion constructs. The surgical creation of a stiff upper segment along with patient osteoporosis has been suggested as etiologies. Materials and Methods: Fifteen fresh-frozen ligamentous T6 - pelvis specimens were divided equally into three Groups: Group 1 - Bilateral pedicle screw and rod instrumentation from T10 to S1, no cement; Group 2 - Instrumentation + 4cc of cement injected into T10 (UIV) and 4cc into T9 (UIV + 1), 2cc of cement injected through each pedicle; & Group 3 - Instrumentation + 4cc of cement in T10 (UIV), 3cc total in T9 (UIV + 1), and 2cc total in T8 (UIV + 2). The pelvis and T6 vertebra were potted. Eccentric axial compression was applied 10mm anterior to the center of T6 using an MTS actuator. Maximum load to failure was measured in newtons (N). The spines were evaluated using fluoroscopy and CT. Results: There was a significant reduction in the number of fractures in Group 3 versus Groups 2 and 1 ( p = 0.0019). There was only one fracture in Group 3, which occurred at T8 (UIV + 2); all five specimens suffered a fracture in Group 2; and five in Group 1. Posterior ligamentous rupture occurred in four specimens in Group 3; three in Group 2; and only one in Group 1. The mean peak load-to-failure values showed an increasing trend from Groups 1 to 3 ( p = 0.38). There was no difference in specimen DEXA values ( p = 0.71). There was no hardware failure in any Group. FEA mirrored the cadaveric data and the maximum load to failure increased from Group 1 to 3. Endplate stresses were reduced in Group 3 versus Groups 1 and 2. Conclusions: In both cadaveric and FEA models, this novel technique of tapering the dose of prophylactic vertebroplasty cement in the UIV, UIV + 1, UIV + 2 decreased the endplate stresses, increased the load required for failure, and significantly reduced the incidence of VCFs above long-segment instrumented constructs. Clinically, this technique may reduce the risk of PJK, PJF, and revision surgery.


  • Comparative In Vitro Biomechanical Analysis of a Novel Posterior Cervical Fixation Technique Versus Conventional Posterior-based Constructs

    by Camilo Molina, Ryan M. Kretzer, Nianbin Hu, Hidemasa Umekoji, Bryan W. Cunningham, Hassan Serhan

    Comparative in vitro, cadaveric biomechanical study. To compare the kinematic response of a new posterior cervical midline surgical technique versus that of conventional fixation techniques. A new method was designed using alternating bilateral intralaminar screws connected with a single midline rod. This technique provides the theoretical benefits of less operative dissection and reduced implant cost, but the acute flexibility properties remain unknown. Using an in vitro cadaveric model, the study objective was to define the operative level(s) changes in multidirectional flexibility after posterior destabilization/reconstruction from C3 to C6. A 6 degree of freedom spine stimulator was used to test flexibility in 7 human cadaveric specimens. Flexion-extension, lateral bending, and axial rotation were tested in the intact condition, followed by destabilization by a simulated posterior column injury from C3 to C6. Specimens were then reconstructed from C3 to C6 and tested in the following sequence: sublaminar hook rod (SH), lateral mass screw rod (LMR), midline laminectomy from C3 to C6 with LMR (MLR), and midline posterior fixation from C3 to C6 (SMF). Range of motion (ROM) and neutral zone were quantified and analyzed. Significant increases in ROM and neutral zone at C3 to C6 were found under all loading conditions for the destabilized condition and intact spine versus all other treatments (P0.05). Notably, LMR and MLR provided significantly more stability than SH in axial rotation (P<0.05). Data produced suggest that the new, midline rod fixation approach provides less biomechanical stability than conventional posterior cervical reconstruction techniques. In addition, the high incidence of laminar fracture during screw placement and close proximity of the screw trajectory and polyaxial heads to the dura suggest a practical limitation as well.


  • Managing Design Excellence Tools During the Development of New Orthopaedic Implants

    by Henri J. P. Défossez, Hassan Serhan

    Design excellence (DEX) tools have been widely used for years in some industries for their potential to facilitate new product development. The medical sector, targeted by cost pressures, has therefore started adopting them. Numerous tools are available; however only appropriate deployment during the new product development stages can optimize the overall process. The primary study objectives were to describe generic tools and illustrate their implementation and management during the development of new orthopaedic implants, and compile a reference package. Secondary objectives were to present the DEX tool investment costs and savings, since the method can require significant resources for which companies must carefully plan. The publicly available DEX method “Define Measure Analyze Design Verify Validate” was adopted and implemented during the development of a new spinal implant. Several tools proved most successful at developing the correct product, addressing clinical needs, and increasing market penetration potential, while reducing design iterations and manufacturing validations. Cost analysis and Pugh Matrix coupled with multi generation planning enabled developing a strong rationale to activate the project, set the vision and goals. improved risk management and product map established a robust technical verification-validation program. Design of experiments and process quantification facilitated design for manufacturing of critical features, as early as the concept phase. Biomechanical testing with analysis of variance provided a validation model with a recognized statistical performance baseline. Within those tools, only certain ones required minimum resources (i.e., business case, multi generational plan, project value proposition, Pugh Matrix, critical To quality process validation techniques), while others required significant investments (i.e., voice of customer, product usage map, improved risk management, design of experiments, biomechanical testing techniques). All used techniques provided savings exceeding investment costs. Some other tools were considered and found less relevant. A matrix summarized the investment costs and generated estimated savings. Globally, all companies can benefit from using DEX by smartly selecting and estimating those tools with best return on investment at the start of the project. For this, a good understanding of the available company resources, background and development strategy are needed. In conclusion, it was possible to illustrate that appropriate management of design excellence tools can greatly facilitate the development of new orthopaedic implant systems.


  • Would CoCr Rods Provide Better Correctional Forces Than Stainless Steel or Titanium for Rigid Scoliosis Curves?

    by Hassan Serhan, Devdatt Mhatre, Peter Newton, Paul Giorgio, Peter Sturm

    Comparative in vitro, biomechanical study. Compare the effect of rod curvature and material properties on rod flattening and correctional forces. Traditional methods of correction for large progressive deformities involve 3-dimensional correction, performed with an attempt to reach a balanced correction in all planes, spinal instrumentation, and fusion. Increasing attention to the transverse plane correction has developed after the introduction of segmental pedicle screws into the treatment of idiopathic scoliosis. Approximation of the spine (pedicle screws or hooks) to the rods remains the heart of many deformity procedures. Therefore, it is crucial that the instrumentation used provide and maintain the initial correction of the spinal deformity while minimizing potential intraoperative failures. Two experiments were performed using 80 rods made from 4 different materials namely: stainless steel (SS), titanium (Ti), cobalt chromium (CoCr), and ultrahigh strength stainless steel (UHSS). Half of the rods were contoured to 20 degrees, whereas the reaming contoured to 30 degrees. Half of the rods were approximated to a synthetic spine models to measure the flattening of the rods when approximated to highly rigid spine. The other half was used to measure the correctional forces produced by each rod type and curvature. For the 20-degree pre-bend rods, Ti was the best in maintaining its original shape followed by UHSS, SS, and CoCr of 90%, 77%, 62.5%, and 54.4%, respectively. The 30-degree pre-bend showed exactly a similar trend with 80.7% for Ti, 71% for UHSS, 54.6% for SS, and 48.1% for the CoCr rods. For 30-degree pre-bend CoCr and UHSS rods, the intraoperative reduction forces were almost 42% and 10% higher than the Ti and SS rods, respectively. The correctional force produced by the Ti 30-degree pre-bend rod was approximately 67% that of a CoCr and UHSS rods. CoCr and UHSS rods have the ability to produce the highest correction forces, however, both can plastically deform in a very rigid curves. Therefore, it is critical to have sense of the quality of the bone fixation as well as the curve flexibility when selecting for appropriate rod size material and contouring the rod to the desired shape.


  • Would an Anatomically Shaped Lumbar Interbody Cage Provide Better Stability? An In Vitro Cadaveric Biomechanical Evaluation

    by Parmenion P. Tsitsopoulos, Hassan Serhan, Leonard I. Voronov, Gerard Carandang, Robert M. Havey, Alexander J. Ghanayem, Avinash G. Patwardhan

    A biomechanical cadaveric study of lumbar spine segments. To compare the immediate stability provided by parallel-shaped and anatomically shaped carbon fiber interbody fusion I/F cages in posterior lumbar interbody fusion (PLIF) and transforaminal lumbar interbody fusion (TLIF) constructs with posterior pedicle screw instrumentation. Few biomechanical data are available on the anatomically shaped cages in PLIF and TLIF constructs. Twenty human lumbar segments were tested in flexion-extension (FE) (8 N m flexion, 6 N m extension), lateral bending (LB) (± 6 N m), and torsional loading (± 5 N m). Each segment was tested in the intact state and after insertion of interbody cages in one of 3 constructs: PLIF with 2 parallel-shaped or anatomically shaped cages and TLIF with 1 anatomically shaped cage. All cages received supplementary pedicle screw fixation. The range-of-motion (ROM) values after cage insertion and posterior fixation were compared with the intact specimen values using analysis of variance and multiple comparisons with Bonferroni correction. All constructs significantly reduced segmental motion relative to intact (P < 0.001). The motion reductions in FE, LB, and axial rotation were 85 ± 15%, 83 ± 18%, and 67 ± 6.8% for the PLIF construct using parallel cages, 79 ± 5.5%, 87 ± 10%, and 66 ± 20% for PLIF using anatomically shaped cages, and 90 ± 6.8%, 87 ± 12%, and 77 ± 22% for TLIF with an anatomically shaped cage. In FE and LB, the reductions in the ROM caused between the 3 constructs were equivalent (P > 0.05). In axial rotation, the TLIF cage provided significantly greater limitation in the ROM compared with the parallel-shaped PLIF cage (P = 0.01). The parallel-shaped and anatomically shaped I/F cages provided similar stability in a PLIF construct. The greater stability of the TLIF construct was likely due to a more anterior placement of the TLIF cage and preservation of the contralateral facet joint.


  • Direct Lateral Approach to Lumbar Fusion Is a Biomechanically Equivalent Alternative to the Anterior Approach

    by Cory J. Laws, Dezba G. Coughlin, Jeffrey C. Lotz, Hassan A. Serhan, Serena S. Hu

    A human cadaveric biomechanical study of lumbar mobility before and after fusion and with or without supplemental instrumentation for 5 instrumentation configurations. To determine the biomechanical differences between anterior lumbar interbody fusion (ALIF) and direct lateral interbody fusion (DLIF) with and without supplementary instrumentation. Some prior studies have compared various surgical approaches using the same interbody device whereas others have investigated the stabilizing effect of supplemental instrumentation. No published studies have performed a side-by-side comparison of standard and minimally invasive techniques with and without supplemental instrumentation. Eight human lumbosacral specimens (16 motion segments) were tested in each of the 5 following configurations: (1) intact, (2) with ALIF or DLIF cage, (3) with cage plus stabilizing plate, (4) with cage plus unilateral pedicle screw fixation (PSF), and (5) with cage plus bilateral PSF. Pure moments were applied to induce specimen flexion, extension, lateral bending, and axial rotation. Three-dimensional kinematic responses were measured and used to calculate range of motion, stiffness, and neutral zone. Compared to the intact state, DLIF significantly reduced range of motion in flexion, extension, and lateral bending (P = 0.0117, P = 0.0015, P = 0.0031). Supplemental instrumentation significantly increased fused-specimen stiffness for both DLIF and ALIF groups. For the ALIF group, bilateral PSF increased stiffness relative to stand-alone cage by 455% in flexion and 317% in lateral bending (P = 0.0009 and P < 0.0001). The plate increased ALIF group stiffness by 211% in extension and 256% in axial rotation (P = 0.0467 and P = 0.0303). For the DLIF group, bilateral PSF increased stiffness by 350% in flexion and 222% in extension (P < 0.0001 and P = 0.0008). No differences were observed between ALIF and DLIF groups supplemented with bilateral PSF. Our data support that the direct lateral approach, when supplemented with bilateral PSF, is a minimally invasive and biomechanically stable alternative to the open, anterior approach to lumbar spine fusion.


  • Open Access

    Motion-preserving technologies for degenerative lumbar spine: The past, present, and future horizons

    by Hassan Serhan, Devdatt Mhatre, Henri Defossez, Christopher M. Bono

    Over the past few decades, remarkable advancements in the understanding of the origin of low-back pain and lumbar spinal disorders have been achieved. Spinal fusion is generally considered the "gold standard" in the treatment of low-back pain; however, fusion is also associated with accelerated degeneration of adjacent levels. Spinal arthroplasty and dynamic stabilization technologies, as well as the continuous improvement in diagnosis and surgical interventions, have opened a new era of treatment options. Recent advancements in nonfusion technologies such as motion-preservation devices and posterior dynamic stabilization may change the gold standard. These devices are designed with the intent to provide stabilization and eliminate pain while preserving motion of the functional spinal unit. The adaption of nonfusion technologies by the surgical community and payers for the treatment of degenerative spinal conditions will depend on the long-term clinical outcome of controlled randomized clinical studies. Although the development of nonfusion technology has just started and the adoption is very slow, it may be considered a viable option for motion preservation in coming years. This review article provides technical and surgical views from the past and from the present, as well as a glance at the future endeavors and challenges in instrumentation development for lumbar spinal disorders. © 2011 SAS - The International Society for the Advancement of Spine Surgery. Published by Elsevier Inc. All rights reserved.