Improvement of the Microstructure and X-ray Performance of Ultrathin Ru/C Multilayer Mirror after High Temperature Treatment
Open Access
Abstract
Ru/C multilayer mirrors with a period of 2.5 nm and 150 bilayers were studied under high-temperature annealing and long-term storage. A general increase in the reflectivity was observed after annealing at different temperatures from 300 to 700 °C, during which a maximum enhancement of around 14% was obtained at 600 °C. The highest reflectance measured at 8 keV reached 69% after 600 °C annealing. This was accompanied by a 6% expansion of the layer period, which could be mainly attributed to carbon layers. The surface roughness was not affected by the annealing, whereas the polycrystallization of Ru with crystallographic planes parallel to the layer interfaces was enhanced. Combining the transmission-electron microscopy measurements, it was found that the interdiffusion at the C-on-Ru interface was significantly suppressed. The decreased interdiffusion, enhanced optical contrast, and larger multilayer period were the main reasons for the increased reflectance. The 600 °C annealed Ru/C multilayer remained intact after 13 months of storage in air, which also demonstrated significant temporal stability.Keywords
Funding Information
- National Natural Science Foundation of China (61621001)
- National Key R&D Program of China (2016YFA0401304)
- Shanghai Rising-Star Program (19QA1409200)
- Major projects of Science and Technology Commission of Shanghai (17JC1400800)
- Shanghai Municipal Science and Technology Major Project (2017SHZDZX02)
This publication has 23 references indexed in Scilit:
- Comparative study of multilayers used in monochromators for synchrotron-based coherent hard X-ray imagingJournal of Synchrotron Radiation, 2010
- A dedicated small-angle X-ray scattering beamline with a superconducting wiggler source at the NSRRCJournal of Synchrotron Radiation, 2008
- GenX: an extensible X-ray reflectivity refinement program utilizing differential evolutionJournal of Applied Crystallography, 2007
- Variable X-ray excitation for total reflection X-ray fluorescence spectrometry using an Mo/W alloy anode and a tunable double multilayer monochromatorSpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Interdiffusion in soft X-ray multilayer mirrorsThin Solid Films, 1996
- Microstructure - Roughness Interelation in Ru/C and Ru/B4C X-RAY MultilayersMRS Proceedings, 1992
- Microstructure and Stability Comparison of Nanometer Period W/C, Wc/C, and Ru/C Multilayer StructuresMRS Proceedings, 1990
- Reflectance degradation of soft X-ray multilayer filters upon exposure to synchrotron radiationPhysica Scripta, 1990
- Performance of multilayers in intense synchrotron x-ray beamsReview of Scientific Instruments, 1989
- High Resolution Electron Microscopy Study of As-Prepared and Annealed Tungsten-Carbon NultilayersMRS Proceedings, 1989