Calibration of standard radiation thermometers using two fixed points
- 14 January 2020
- journal article
- research article
- Published by IOP Publishing in Metrologia
- Vol. 57 (1) , 014002
Abstract
Radiation thermometry based on the measurement of two fixed points, the so-called n = 2 scheme, is studied in this work. Verification of the scheme was undertaken for various measurement conditions using seven radiation thermometers with nominal centre wavelengths of 650 nm, 890 nm, 900 nm, and 1600 nm. Comparison between the signals calculated using the n = 2 scheme and the signals measured directly with fixed-point cells was studied. For temperatures between the two reference fixed points, the equivalent temperature difference was less than 0.14 K in the temperature range from the In to Cu fixed points, and less than 0.3 K in the temperature range from the Cu to Re–C fixed points. The maximum normalised error was 0.35, confirming the validity of the n = 2 scheme; the consistency was observed not only in the interpolation temperature range, but also in the extrapolation range. The results also indicate that temperature realisation in the range from 150 °C to 2500 °C can be achieved by maintaining only the Zn, Cu, and Re–C fixed-point facilities. The n = 2 scheme would be of great benefit to developing national metrology institutes in terms of time consumed for scale realisation and cost for maintenance of the measurement system.Keywords
This publication has 12 references indexed in Scilit:
- Potential for improved radiation thermometry measurement uncertainty through implementing a primary scale in an industrial laboratoryMeasurement Science and Technology, 2016
- The kelvin redefinition and its mise en pratiquePhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2016
- Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJInternational Journal of Thermophysics, 2014
- Realization of ITS-90 Above the Silver Point at the NIMInternational Journal of Thermophysics, 2011
- Measurement of Thermodynamic Temperature Above the Silver Point on the Basis of the Scheme n = 2International Journal of Thermophysics, 2011
- Uncertainties in the Realization of Thermodynamic Temperature Above the Silver PointInternational Journal of Thermophysics, 2011
- Propagation of Uncertainty Due to Non-linearity in Radiation ThermometersInternational Journal of Thermophysics, 2007
- Metal (carbide)–carbon eutectics for thermometry and radiometry: a review of the first seven yearsMetrologia, 2006
- Physical basis of interpolation equations for radiation thermometryMetrologia, 2003
- Realizing the High-Temperature Part of a Future ITS with the Aid of Eutectic Metal-Carbon Fixed PointsAIP Conference Proceedings, 2003