Peter Saunders
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Peter Saunders has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- David R. White
Independent Researcher, Lower Hutt, New Zealand
4 shared publications - Athikom Manoi
National Institute of Metrology (Thailand), Pathumthani, Thailand
3 shared publications - Blair D. Hall
Measurement Standards Laboratory of New Zealand, Lower Hutt 5010, New Zealand
2 shared publications - Ellie Molloy
Measurement Standards Laboratory of New Zealand, 69 Gracefield Rd, Lower Hutt 5010, New Zealand
2 shared publications Pieter Bloembergen
NMi-van Swinden Laboratory, Nederlands Meetinstituut, PO Box 654, NL-2600 AR Delft, Delft, NL-2600 AR Delf, NETHERLANDS
2 shared publications- Xiaofeng Lu
National Institute of Metrology
2 shared publications
Latest Publications
- Open Access
- 12 November 2026
- Published by IOP Publishing in Measurement Science and Technology
Minimising the uncertainty in T -T90 above the silver point
Above the silver point (~1235 K), the difference between thermodynamic temperature, T, and ITS-90 temperature, T90, can be expressed as an analytic function in terms of the thermodynamic and ITS-90 temperatures of a single point anywhere above the silver point. The uncertainty in this function across the whole radiation thermometry range of ITS-90 depends only on the uncertainty of T -T90 at this one point, and scales with T 2 . This paper develops a criterion for minimising the uncertainty in this T -T90 function. To satisfy this criterion, two radiation thermometry methods are compared for their ability to measure the thermodynamic temperatures of the silver, gold, and copper points-a downwards extrapolation method at short wavelengths using high-temperature fixed points and an upwards extrapolation method from fixed points in the SPRT range of ITS-90 using a longer-wavelength radiation thermometer. It is concluded that the latter method may achieve the lowest uncertainty.
- 12 November 2026
- Published by IOP Publishing in Measurement Science and Technology
Open AccessMinimising the uncertainty in T -T90 above the silver point
Above the silver point (~1235 K), the difference between thermodynamic temperature, T, and ITS-90 temperature, T90, can be expressed as an analytic function in terms of the thermodynamic and ITS-90 temperatures of a single point anywhere above the silver point. The uncertainty in this function across the whole radiation thermometry range of ITS-90 depends only on the uncertainty of T -T90 at this one point, and scales with T 2 . This paper develops a criterion for minimising the uncertainty in this T -T90 function. To satisfy this criterion, two radiation thermometry methods are compared for their ability to measure the thermodynamic temperatures of the silver, gold, and copper points-a downwards extrapolation method at short wavelengths using high-temperature fixed points and an upwards extrapolation method from fixed points in the SPRT range of ITS-90 using a longer-wavelength radiation thermometer. It is concluded that the latter method may achieve the lowest uncertainty.
- 1 October 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (5) , 055005
Uncertainty analysis of MSL’s CCT-K7.2021 key comparison measurements taking account of correlations
The National Research Council of Canada (NRC) recently piloted the second international key comparison of triple point of water cells, CCT-K7.2021, where participants submitted a transfer cell and a report of the temperature difference between their transfer cell and their respective national reference. By comparing the differences between each transfer cell, NRC could calculate the differences between each participant’s national reference. While there was good agreement among all the participants, there was a large variation among the submitted uncertainties. This was possibly due to the complexity of the uncertainty analysis, which typically has many correlated components between the transfer cell and the national reference that partially cancel when the difference is taken. The Measurement Standards Laboratory of New Zealand (MSL) carried out its analysis using a detailed measurement model that included all known correlations and applied an algorithmic approach fully compliant with the Guide to the Expression of Uncertainty in Measurement. As a consequence, MSL submitted an uncertainty value less than half the uncertainty values submitted by almost all of the other participants. This paper describes the measurement model implemented by MSL and demonstrates how accounting correctly for correlations leads to a significantly lower uncertainty. The paper also shows how applying the same method to the previously published NRC analysis results in a reduction in the NRC uncertainty by a factor of about 2.5, making it smaller than the MSL uncertainty.
- 1 October 2025
- Published by IOP Publishing in Metrologia
- Vol. 62 (5) , 055005
Uncertainty analysis of MSL’s CCT-K7.2021 key comparison measurements taking account of correlations
The National Research Council of Canada (NRC) recently piloted the second international key comparison of triple point of water cells, CCT-K7.2021, where participants submitted a transfer cell and a report of the temperature difference between their transfer cell and their respective national reference. By comparing the differences between each transfer cell, NRC could calculate the differences between each participant’s national reference. While there was good agreement among all the participants, there was a large variation among the submitted uncertainties. This was possibly due to the complexity of the uncertainty analysis, which typically has many correlated components between the transfer cell and the national reference that partially cancel when the difference is taken. The Measurement Standards Laboratory of New Zealand (MSL) carried out its analysis using a detailed measurement model that included all known correlations and applied an algorithmic approach fully compliant with the Guide to the Expression of Uncertainty in Measurement. As a consequence, MSL submitted an uncertainty value less than half the uncertainty values submitted by almost all of the other participants. This paper describes the measurement model implemented by MSL and demonstrates how accounting correctly for correlations leads to a significantly lower uncertainty. The paper also shows how applying the same method to the previously published NRC analysis results in a reduction in the NRC uncertainty by a factor of about 2.5, making it smaller than the MSL uncertainty.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 150001
The purposes of measurement uncertainty
It is now more than 40 years since the BIPM outlined the current harmonized approach to the expression of uncertainty in measurement, and 30 years since the pub It is now more than 40 years since the BIPM outlined the current harmonized approach to the expression of uncertainty in measurement, and 30 years since the pub
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 150001
The purposes of measurement uncertainty
It is now more than 40 years since the BIPM outlined the current harmonized approach to the expression of uncertainty in measurement, and 30 years since the pub It is now more than 40 years since the BIPM outlined the current harmonized approach to the expression of uncertainty in measurement, and 30 years since the pub
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 020005
Digital representation of scales and units for temperature and related quantities
The International System of Units (SI) has two units for temperature: the kelvin and the degree Celsius. The kelvin is the base unit for thermodynamic temperatu The International System of Units (SI) has two units for temperature: the kelvin and the degree Celsius. The kelvin is the base unit for thermodynamic temperatu
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 020005
Digital representation of scales and units for temperature and related quantities
The International System of Units (SI) has two units for temperature: the kelvin and the degree Celsius. The kelvin is the base unit for thermodynamic temperatu The International System of Units (SI) has two units for temperature: the kelvin and the degree Celsius. The kelvin is the base unit for thermodynamic temperatu
- 28 February 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 025002
Effects of rotation errors on goniometric measurements
Goniometric measurements are essential for the determination of many optical quantities, and quantifying the effects of errors in the rotation axes on these quantities is a complex task. In this paper, we show how a measurement model for a four-axis goniometric system can be developed to allow the effects of alignment and rotation errors to be included in the uncertainty of the measurement. We use three different computational methods to propagate the uncertainties due to several error sources through the model to the rotation angles and then to the measurement of bidirectional reflectance and integrated diffuse reflectance, a task that would otherwise be intractable. While all three methods give the same result, the GTC Python package is the simplest and intrinsically provides a full uncertainty budget, including all correlations between measurement parameters. We then demonstrate how the development of a measurement model and the use of GTC has improved our understanding of the system. As a consequence, taking advantage of negative correlations between measurements in different geometries allows us to minimise the total uncertainty in integrated diffuse reflectance, lowering the standard uncertainty from 0.0029 to 0.0015.
- 28 February 2022
- Published by IOP Publishing in Metrologia
- Vol. 59 (2) , 025002
Effects of rotation errors on goniometric measurements
Goniometric measurements are essential for the determination of many optical quantities, and quantifying the effects of errors in the rotation axes on these quantities is a complex task. In this paper, we show how a measurement model for a four-axis goniometric system can be developed to allow the effects of alignment and rotation errors to be included in the uncertainty of the measurement. We use three different computational methods to propagate the uncertainties due to several error sources through the model to the rotation angles and then to the measurement of bidirectional reflectance and integrated diffuse reflectance, a task that would otherwise be intractable. While all three methods give the same result, the GTC Python package is the simplest and intrinsically provides a full uncertainty budget, including all correlations between measurement parameters. We then demonstrate how the development of a measurement model and the use of GTC has improved our understanding of the system. As a consequence, taking advantage of negative correlations between measurements in different geometries allows us to minimise the total uncertainty in integrated diffuse reflectance, lowering the standard uncertainty from 0.0029 to 0.0015.
- 13 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035007
On the uncertainties in the realization of the kelvin based on thermodynamic temperatures of high-temperature fixed-point cells
In July 2016 the Consultative Committee for Thermometry’s Non-Contact Thermometry Working Group formed a task group to compile a complete list of uncertainties for high-temperature fixed points, categorize them as well specified or not, and recommend areas of future research. We describe herein two paths to realizing T by indirect primary radiometry using high-temperature fixed-point blackbody cells: one in which published values for the metal–carbon eutectic material transition temperatures are used and the other where a set of cells has their transition temperatures determined directly. The uncertainty components that need to be considered for each path are given together with typically achievable values and how well those values are known. This work concentrates on Co–C, Pt–C and Re–C.
- 13 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035007
On the uncertainties in the realization of the kelvin based on thermodynamic temperatures of high-temperature fixed-point cells
In July 2016 the Consultative Committee for Thermometry’s Non-Contact Thermometry Working Group formed a task group to compile a complete list of uncertainties for high-temperature fixed points, categorize them as well specified or not, and recommend areas of future research. We describe herein two paths to realizing T by indirect primary radiometry using high-temperature fixed-point blackbody cells: one in which published values for the metal–carbon eutectic material transition temperatures are used and the other where a set of cells has their transition temperatures determined directly. The uncertainty components that need to be considered for each path are given together with typically achievable values and how well those values are known. This work concentrates on Co–C, Pt–C and Re–C.
- 9 June 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (4) , 045007
The non-uniqueness of ITS-90 above the silver point and its impact on values of T − T 90
Non-uniqueness is a fundamental limit to the reproducibility of a defined temperature scale. In this paper, the non-uniqueness of temperatures, T 90 , on the International Temperature Scale of 1990 (ITS-90) above the silver point is fully investigated for the first time. The non-uniqueness arises from three causes: inconsistency in extrapolation with the choice of the three allowable ITS-90 reference fixed points; a wavelength dependence of T 90 due to the difference between thermodynamic temperature, T , and T 90 at these reference fixed points; and a further wavelength dependence arising from the discrepancy between the value of the second radiation constant defined on ITS-90 and its value derived from fundamental constants. The non-uniqueness is quantified by deriving an exact expression for T − T 90 above the silver point and calculating the differences in this expression as a function of reference fixed point and wavelength. In the worst case, the non-uniqueness is about 100 mK, and T − T 90 is as much as 400 mK, at 3000 °C.
- 9 June 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (4) , 045007
The non-uniqueness of ITS-90 above the silver point and its impact on values of T − T 90
Non-uniqueness is a fundamental limit to the reproducibility of a defined temperature scale. In this paper, the non-uniqueness of temperatures, T 90 , on the International Temperature Scale of 1990 (ITS-90) above the silver point is fully investigated for the first time. The non-uniqueness arises from three causes: inconsistency in extrapolation with the choice of the three allowable ITS-90 reference fixed points; a wavelength dependence of T 90 due to the difference between thermodynamic temperature, T , and T 90 at these reference fixed points; and a further wavelength dependence arising from the discrepancy between the value of the second radiation constant defined on ITS-90 and its value derived from fundamental constants. The non-uniqueness is quantified by deriving an exact expression for T − T 90 above the silver point and calculating the differences in this expression as a function of reference fixed point and wavelength. In the worst case, the non-uniqueness is about 100 mK, and T − T 90 is as much as 400 mK, at 3000 °C.
- 25 March 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (2) , 024002
Uncertainties in blackbody corrections for low-temperature radiation thermometers
Equations are derived for propagating the uncertainties contributing to the blackbody corrections for the calibration of low-temperature radiation thermometers operating over a spectral range near the 8 µm–14 µm band. These equations include the full Planck treatment of spectral radiance, which is necessary at these long wavelengths, and account for the thermometer bandwidth. The influence quantities include the source emissivity, reference temperature, reflected ambient radiation, detector temperature, and spectral responsivity. Various cases are considered when using either a blackbody cavity or a flat-plate calibrator as the calibration source, and when using a contact thermometer or a radiation thermometer as the reference. Total uncertainties tend to be smallest when a radiation thermometer is used as the reference as, in this case, the influence of the source emissivity is minimised.
- 25 March 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (2) , 024002
Uncertainties in blackbody corrections for low-temperature radiation thermometers
Equations are derived for propagating the uncertainties contributing to the blackbody corrections for the calibration of low-temperature radiation thermometers operating over a spectral range near the 8 µm–14 µm band. These equations include the full Planck treatment of spectral radiance, which is necessary at these long wavelengths, and account for the thermometer bandwidth. The influence quantities include the source emissivity, reference temperature, reflected ambient radiation, detector temperature, and spectral responsivity. Various cases are considered when using either a blackbody cavity or a flat-plate calibrator as the calibration source, and when using a contact thermometer or a radiation thermometer as the reference. Total uncertainties tend to be smallest when a radiation thermometer is used as the reference as, in this case, the influence of the source emissivity is minimised.
- 21 January 2020
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 41 (3) , 1-6
T − T90 for Radiation Thermometry Realization Above the Copper Point
- 21 January 2020
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 41 (3) , 1-6
T − T90 for Radiation Thermometry Realization Above the Copper Point
- 14 January 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (1) , 014002
Calibration of standard radiation thermometers using two fixed points
Radiation thermometry based on the measurement of two fixed points, the so-called n = 2 scheme, is studied in this work. Verification of the scheme was undertaken for various measurement conditions using seven radiation thermometers with nominal centre wavelengths of 650 nm, 890 nm, 900 nm, and 1600 nm. Comparison between the signals calculated using the n = 2 scheme and the signals measured directly with fixed-point cells was studied. For temperatures between the two reference fixed points, the equivalent temperature difference was less than 0.14 K in the temperature range from the In to Cu fixed points, and less than 0.3 K in the temperature range from the Cu to Re–C fixed points. The maximum normalised error was 0.35, confirming the validity of the n = 2 scheme; the consistency was observed not only in the interpolation temperature range, but also in the extrapolation range. The results also indicate that temperature realisation in the range from 150 °C to 2500 °C can be achieved by maintaining only the Zn, Cu, and Re–C fixed-point facilities. The n = 2 scheme would be of great benefit to developing national metrology institutes in terms of time consumed for scale realisation and cost for maintenance of the measurement system.
- 14 January 2020
- Published by IOP Publishing in Metrologia
- Vol. 57 (1) , 014002
Calibration of standard radiation thermometers using two fixed points
Radiation thermometry based on the measurement of two fixed points, the so-called n = 2 scheme, is studied in this work. Verification of the scheme was undertaken for various measurement conditions using seven radiation thermometers with nominal centre wavelengths of 650 nm, 890 nm, 900 nm, and 1600 nm. Comparison between the signals calculated using the n = 2 scheme and the signals measured directly with fixed-point cells was studied. For temperatures between the two reference fixed points, the equivalent temperature difference was less than 0.14 K in the temperature range from the In to Cu fixed points, and less than 0.3 K in the temperature range from the Cu to Re–C fixed points. The maximum normalised error was 0.35, confirming the validity of the n = 2 scheme; the consistency was observed not only in the interpolation temperature range, but also in the extrapolation range. The results also indicate that temperature realisation in the range from 150 °C to 2500 °C can be achieved by maintaining only the Zn, Cu, and Re–C fixed-point facilities. The n = 2 scheme would be of great benefit to developing national metrology institutes in terms of time consumed for scale realisation and cost for maintenance of the measurement system.