A new method for anti‐negative interference of calcium dobesilate in serum creatinine enzymatic analysis
Open Access
- 30 July 2021
- journal article
- research article
- Published by Wiley in Journal of Clinical Laboratory Analysis
- Vol. 35 (9) , e23928
Abstract
Background: Serum creatinine is a widely used biomarker for evaluating renal function. Sarcosine oxidase enzymatic (SOE) analysis is currently the most widely used method for the detection of creatinine. This method was negatively interfered with by calcium dobesilate, causing pseudo‐reduced results. The aim of this study was to explore a new method to alleviate the negative interference of this drug on creatinine detection.Method: We formulated eight drug concentrations and 12 creatinine concentrations from serum. The SOE method, the new method, and the Jaffe method were used for detection in five systems. Creatinine biases were analyzed under the conditions with or without the interference of calcium dobesilate, at consistent or inconsistent creatinine concentrations. Creatinine concentrations were also analyzed at three medical decision levels (MDLs).Results: Calcium dobesilate had negative interference in creatinine SOE analysis. With the increase in calcium dobesilate concentrations, the negative bias increases. The new BG method showed an anti‐negative interference effect. In the Roche system, the BG method reduced the negative bias from −71.11% to −16.7%. In the Abbott system, bias was reduced from −45.15% to −2.74%. In the Beckman system, the bias was reduced from −65.36% to −7.58%. In the Siemens system, the bias was reduced from −58.62% to −7.58%. In the Mindray system, the bias was reduced from −36.29% to −6.84%.Conclusion: The new method alleviated the negative interference of calcium dobesilate in creatinine SOE detection. The negative bias could be reduced from −60% or −70% to less than −20%.Keywords
This publication has 19 references indexed in Scilit:
- Strong Negative Interference by Calcium Dobesilate in Sarcosine Oxidase Assays for Serum Creatinine Involving the Trinder ReactionMedicine, 2015
- Comparison between ADVIA Chemistry systems Enzymatic Creatinine_2 method and ADVIA Chemistry systems Creatinine method (kinetic Jaffe method) for determining creatinineScandinavian Journal of Clinical and Laboratory Investigation, 2014
- Modern Management of Hemorrhoidal DiseaseGastroenterology Clinics of North America, 2013
- Strong negative interference of ethamsylate (Dicynone®) in serum creatinine quantification via enzymatic assay using Trinder reactionScandinavian Journal of Clinical and Laboratory Investigation, 2013
- Creatinine Estimation and InterferenceIndian Journal of Clinical Biochemistry, 2013
- Therapeutic effects of calcium dobesilate on diabetic nephropathy mediated through reduction of expression of PAI-1Experimental and Therapeutic Medicine, 2012
- Creatine metabolism and the urea cycleMolecular Genetics and Metabolism, 2010
- Catecholamine Interference in Enzymatic Creatinine AssaysClinical Chemistry, 2009
- Ascorbic acid interference in the measurement of serum biochemical parameters: In vivo and in vitro studiesClinical Biochemistry, 2006
- Calcium DobesilateGeneral Pharmacology: The Vascular System, 1998