Reoperation and revision rates at ten years after 1,312 cemented Thompson's hemiarthroplasties ANY NEED TO CHANGE TO A DIFFERENT IMPLANT?
Open Access
- 4 September 2022
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 3 (9) , 710-715
Abstract
Aims Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson's hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results In total, 1,312 Thompson's hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion The Thompson's stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson's implant as a cost-effective option for frail hip fracture patients.Keywords
This publication has 25 references indexed in Scilit:
- Historical Implant or Current Best Standard? Minimum Five Year Follow-Up Outcomes of Cemented Thompson HemiarthroplastiesThe Journal of Arthroplasty, 2014
- Hip hemiarthroplasty: from Venable and Bohlman to Moore and ThompsonInternational Orthopaedics, 2013
- Periprosthetic fractures around hip hemiarthroplasty performed for hip fractureInjury, 2013
- Comparison of the Exeter Trauma Stem and the Thompson Hemiarthroplasty for Intracapsular Hip FracturesHIP International, 2012
- Cemented Thompson hemiarthroplasty versus cemented Exeter Trauma Stem (ETS) hemiarthroplasty for intracapsular hip fractures: A randomised trial of 200 patientsInjury, 2012
- A national analysis of complications following hemiarthroplasty for hip fracture in older patientsQJM: An International Journal of Medicine, 2012
- Projected incidence of proximal femoral fracture in England: A report from the NHS Hip Fracture Anaesthesia Network (HIPFAN)Injury, 2011
- Different competing risks models applied to data from the Australian Orthopaedic Association National Joint Replacement RegistryActa Orthopaedica, 2011
- Cemented versus uncemented hemiarthroplasty for intracapsular hip fracturesThe Journal of Bone and Joint Surgery. British volume, 2010
- Hip Fracture Patients at Risk of Second Hip Fracture: A Nationwide Population-Based Cohort Study of 169,145 Cases During 1977–2001Journal of Bone and Mineral Research, 2009