SJSimon S. Jameson

Simon S. Jameson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Simon S. Jameson has a total of 71 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reoperation and revision rates at ten years after 1,312 cemented Thompson's hemiarthroplasties ANY NEED TO CHANGE TO A DIFFERENT IMPLANT?

    by Sameer K. Khan, Ben Tyas, Amy Shenfine, Simon S. Jameson, Dominic S. Inman, Scott D. Muller, Mike R. Reed

    Aims Despite multiple trials and case series on hip hemiarthroplasty designs, guidance is still lacking on which implant to use. One particularly deficient area is long-term outcomes. We present over 1,000 consecutive cemented Thompson's hemiarthroplasties over a ten-year period, recording all accessible patient and implant outcomes. Methods Patient identifiers for a consecutive cohort treated between 1 January 2003 and 31 December 2011 were linked to radiographs, surgical notes, clinic letters, and mortality data from a national dataset. This allowed charting of their postoperative course, complications, readmissions, returns to theatre, revisions, and deaths. We also identified all postoperative attendances at the Emergency and Outpatient Departments, and recorded any subsequent skeletal injuries. Results In total, 1,312 Thompson's hemiarthroplasties were analyzed (mean age at surgery 82.8 years); 125 complications were recorded, necessitating 82 returns to theatre. These included 14 patients undergoing aspiration or manipulation under anaesthesia, 68 reoperations (5.2%) for debridement and implant retention (n = 12), haematoma evacuation (n = 2), open reduction for dislocation (n = 1), fixation of periprosthetic fracture (n = 5), and 48 revised stems (3.7%), for infection (n = 13), dislocation (n = 12), aseptic loosening (n = 9), persistent pain (n = 6), periprosthetic fracture (n = 4), acetabular erosion (n = 3), and metastatic bone disease (n = 1). Their status at ten years is summarized as follows: 1,180 (89.9%) dead without revision, 34 (2.6%) dead having had revision, 84 (6.6%) alive with the stem unrevised, and 14 (1.1%) alive having had revision. Cumulative implant survivorship was 90.3% at ten years; patient survivorship was 7.4%. Conclusion The Thompson's stem demonstrates very low rates of complications requiring reoperation and revision, up to ten years after the index procedure. Fewer than one in ten patients live for ten years after fracture. This study supports the use of a cemented Thompson's implant as a cost-effective option for frail hip fracture patients.


  • Open Access

    Implant Optimisation for Primary Hip Replacement in Patients over 60 Years with Osteoarthritis: A Cohort Study of Clinical Outcomes and Implant Costs Using Data from England and Wales

    by Simon S. Jameson, James Mason, Paul N. Baker, Paul J. Gregg, David J. Deehan, Mike R. Reed

    Hip replacement is one of the most commonly performed surgical procedures worldwide; hundreds of implant configurations provide options for femoral head size, joint surface material and fixation method with dramatically varying costs. Robust comparative evidence to inform the choice of implant is needed. This retrospective cohort study uses linked national databases from England and Wales to determine the optimal type of replacement for patients over 60 years undergoing hip replacement for osteoarthritis. Implants included were the commonest brand from each of the four types of replacement (cemented, cementless, hybrid and resurfacing); the reference prosthesis was the cemented hip procedure. Patient reported outcome scores (PROMs), costs and risk of repeat (revision) surgery were examined. Multivariable analyses included analysis of covariance to assess improvement in PROMs (Oxford hip score, OHS, and EQ5D index) (9159 linked episodes) and competing risks modelling of implant survival (79,775 procedures). Cost of implants and ancillary equipment were obtained from National Health Service procurement data. EQ5D score improvements (at 6 months) were similar for all hip replacement types. In females, revision risk was significantly higher in cementless hip prostheses (hazard ratio, HR = 2.22, p<0.001), when compared to the reference hip. Although improvement in OHS was statistically higher (22.1 versus 20.5, p<0.001) for cementless implants, this small difference is unlikely to be clinically important. In males, revision risk was significantly higher in cementless (HR = 1.95, p = 0.003) and resurfacing implants, HR = 3.46, p<0.001), with no differences in OHS. Material costs were lowest with the reference implant (cemented, range £1103 to £1524) and highest with cementless implants (£1928 to £4285). Limitations include the design of the study, which is intrinsically vulnerable to omitted variables, a paucity of long-term implant survival data (reflecting the duration of data collection), the possibility of revision under-reporting, response bias within PROMs data, and issues associated with current outcome scoring systems, which may not accurately reflect level of improvement in some patients. Cement fixation, using a polyethylene cup and a standard sized head offers good outcomes, with the lowest risks and at the lowest costs. The most commonly used cementless and resurfacing implants were associated with higher risk of revision and were more costly, while perceptions of improved function and longevity were unsupported.


  • Open Access

    No functional benefit of larger femoral heads and alternative bearings at 6 months following primary hip replacement

    by Simon S Jameson, James M Mason, Paul N Baker, Paul J Gregg, David J Deehan, Mike R Reed

    Background and purpose — There has been a recent trend towards the use of greater femoral head sizes in an attempt to improve function and enhance stability after primary hip replacement. This has been associated with the use of alternative bearings, theoretically to reduce wear and improve implant longevity. Methods — We examined the influence of these variables on patient-reported outcome measures (PROMs) for a consecutive series of primary hip replacements using National Joint Registry (NJR) and PROMs-linked data. To minimize the confounding influence of implant design factors, the single most commonly used brand in England and Wales (DePuy Corail Pinnacle) was examined. Improvement in patient hip-specific outcomes (Oxford hip score, OHS), general health outcomes (Euroqol, EQ-5D), and rates of self-reported complications (bleeding, wound problems, re-admission, and reoperation) were compared for different head sizes (28-mm, 32-mm, and 36-mm) and bearings (metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and ceramic-on-ceramic (CoC)), adjusting for differences in case mix. Results — At a mean follow-up of 7 months, improvements in OHS and EQ5D index were similar for 28-mm and 36-mm heads. A 32-mm head was associated with poorer function (OHS: 20, 99% CI: 19–21, p = 0.002; EQ5D index: 0.39, 99% CI: 0.36–0.42, p = 0.004), although these small differences may not be of clinical importance. There were no statistically significant benefits of either CoP or CoC bearings compared to a MoP bearing. Complication rates were similar within comparisons of head sizes or bearings. Interpretation — In this short-term study, we did not find any functional benefits of larger head sizes or alternative bearings, after adjusting for other influences. We question their use in routine primary hip replacement given the lack of evidence of improved long-term survival in the literature.


  • Open Access

    Have cementless and resurfacing components improved the medium-term results of hip replacement for patients under 60 years of age?

    by Simon S Jameson, James Mason, Paul Baker, Paul J Gregg, Martyn Porter, David J Deehan, Mike R Reed

    Background and purpose — The optimal hip replacement for young patients remains unknown. We compared patient-reported outcome measures (PROMs), revision risk, and implant costs over a range of hip replacements. Methods — We included hip replacements for osteoarthritis in patients under 60 years of age performed between 2003 and 2010 using the commonest brand of cemented, cementless, hybrid, or resurfacing prosthesis (11,622 women and 13,087 men). The reference implant comprised a cemented stem with a conventional polyethylene cemented cup and a standard-sized head (28- or 32-mm). Differences in implant survival were assessed using competing-risks models, adjusted for known prognostic influences. Analysis of covariance was used to assess improvement in PROMs (Oxford hip score (OHS) and EQ5D index) in 2014 linked procedures. Results — In males, PROMs and implant survival were similar across all types of implants. In females, revision was statistically significantly higher in hard-bearing and/or small-stem cementless implants (hazard ratio (HR) = 4) and resurfacings (small head sizes (< 48 mm): HR = 6; large head sizes (≥ 48 mm): HR = 5) when compared to the reference cemented implant. In component combinations with equivalent survival, women reported significantly greater improvements in OHS with hybrid implants (22, p = 0.006) and cementless implants (21, p = 0.03) (reference, 18), but similar EQ5D index. For men and women, National Health Service (NHS) costs were lowest with the reference implant and highest with a hard-bearing cementless replacement. Interpretation — In young women, hybrids offer a balance of good early functional improvement and low revision risk. Fully cementless and resurfacing components are more costly and do not provide any additional benefit for younger patients.


  • Open Access

    Evidence-base for aspirin as venous thromboembolic prophylaxis following joint replacement

    by S. S. Jameson, P. N. Baker, D. J. Deehan, A. Port, M. R. Reed

    The National Institute for Health and Clinical Excellence (NICE) has thus far relied on historical data and predominantly industry-sponsored trials to provide evidence for venous thromboembolic (VTE) prophylaxis in joint replacement patients. We argue that the NICE guidelines may be reliant on assumptions that are in need of revision. Following the publication of large scale, independent observational studies showing little difference between low-molecular-weight heparins and aspirin, and recent changes to the guidance provided by other international bodies, should NICE reconsider their recommendations? Cite this article: Bone Joint Res 2014;3:146–9.


  • Cemented hemiarthroplasty or hip replacement for intracapsular neck of femur fracture? A comparison of 7732 matched patients using national data

    by Simon S. Jameson, Deborah Lees, Philip James, Andrew Johnson, Christopher Nachtsheim, James L. McVie, Amar Rangan, Scott D. Muller, Mike R. Reed


  • Increasing age and female gender are associated with early knee replacement following arthroscopy

    by Simon S. Jameson, Stephen P. Rushton, Daniel Dowen, Paul Baker, Philip James, Mike R. Reed, David Deehan

    Purpose: Early knee replacement following arthroscopy may be perceived as a failure of the original treatment and thus a poor use of resources. Factors that may be associated with increased risk of early replacement were explored in this study.Methods: All adult patients who underwent planned knee arthroscopy in a national cohort over a 6‐month period in 2005 were extracted from the administrative hospital admissions database and linked to determine whether and when a knee replacement occurred on the same knee within the subsequent 5 years. A combination of survival analysis and mixed effect modelling was used to investigate risk factors for replacement.Results: There were a total of 20,556 arthroscopies, of which 2,161 (10.6 %) subsequently underwent knee replacement. For patients under 60 years, female gender (62.1 % higher risk, p < 0.001) and increasing age (12.7 % increased risk per increasing year of age, p < 0.001) were significant associations for requiring knee replacement, after risk adjusting. Of those aged ≥60, 12.7 % (576) had undergone a replacement at 1 year following arthroscopy. Females (33 % higher risk), increasing age (7.3 % increased risk per increasing year of age, p < 0.001) and hypertension (1,600 % higher risk, p < 0.001) were significant predictors. The risk associated with increased age was not proportional for the older age group, with risk declining as time passed from arthroscopy, indicating other factors were influencing progression to knee replacement.Conclusions: The predictors of early knee replacement following arthroscopy were female sex, age over 60 years and hypertension, irrespective of type of operation. This work may contribute to national recommendations regarding the provision of arthroscopy for patients over 60 years.Level of evidence: III.


  • Independent predictors of failure up to 7.5 years after 35 386 single-brand cementless total hip replacements

    by S. S. Jameson, P. N. Baker, J. Mason, M. Rymaszewska, P. J. Gregg, D. J. Deehan, M. R. Reed

    The popularity of cementless total hip replacement (THR) has surpassed cemented THR in England and Wales. This retrospective cohort study records survival time to revision following primary cementless THR with the most common combination (accounting for almost a third of all cementless THRs), and explores risk factors independently associated with failure, using data from the National Joint Registry for England and Wales. Patients with osteoarthritis who had a DePuy Corail/Pinnacle THR implanted between the establishment of the registry in 2003 and 31 December 2010 were included within analyses. There were 35 386 procedures. Cox proportional hazard models were used to analyse the extent to which the risk of revision was related to patient, surgeon and implant covariates. The overall rate of revision at five years was 2.4% (99% confidence interval 2.02 to 2.79). In the final adjusted model, we found that the risk of revision was significantly higher in patients receiving metal-on-metal (MoM: hazard ratio (HR) 1.93, p < 0.001) and ceramic-on-ceramic bearings (CoC: HR 1.55, p = 0.003) compared with the best performing bearing (metal-on-polyethylene). The risk of revision was also greater for smaller femoral stems (sizes 8 to 10: HR 1.82, p < 0.001) compared with mid-range sizes. In a secondary analysis of only patients where body mass index (BMI) data were available (n = 17 166), BMI ≥ 30 kg/m2significantly increased the risk of revision (HR 1.55, p = 0.002). The influence of the bearing on the risk of revision remained significant (MoM: HR 2.19, p < 0.001; CoC: HR 2.09, p = 0.001). The risk of revision was independent of age, gender, head size and offset, shell, liner and stem type, and surgeon characteristics.We found significant differences in failure between bearing surfaces and femoral stem size after adjustment for a range of covariates in a large cohort of single-brand cementless THRs. In this study of procedures performed since 2003, hard bearings had significantly higher rates of revision, but we found no evidence that head size had an effect. Patient characteristics, such as BMI and American Society of Anesthesiologists grade, also influence the survival of cementless components.Cite this article: Bone Joint J 2013;95-B:747–57.


  • The design of the acetabular component and size of the femoral head influence the risk of revision following 34 721 single-brand cemented hip replacements

    by S. S. Jameson, P. N. Baker, J. Mason, P. J. Gregg, N. Brewster, D. J. Deehan, M. R. Reed

    Despite excellent results, the use of cemented total hip replacement (THR) is declining. This retrospective cohort study records survival time to revision following primary cemented THR using the most common combination of components that accounted for almost a quarter of all cemented THRs, exploring risk factors independently associated with failure. All patients with osteoarthritis who had an Exeter V40/Contemporary THR (Stryker) implanted before 31 December 2010 and recorded in the National Joint Registry for England and Wales were included in the analysis. Cox’s proportional hazard models were used to analyse the extent to which risk of revision was related to patient, surgeon and implant covariates, with a significance threshold of p < 0.01. A total of 34 721 THRs were included in the study. The overall seven-year rate of revision for any reason was 1.70% (99% confidence interval (CI) 1.28 to 2.12). In the final adjusted model the risk of revision was significantly higher in THRs with the Contemporary hooded component (hazard ratio (HR) 1.88, p < 0.001) than with the flanged version, and in smaller head sizes (< 28 mm) compared with 28 mm diameter heads (HR 1.50, p = 0.005). The seven-year revision rate was 1.16% (99% CI 0.69 to 1.63) with a 28 mm diameter head and flanged component. The overall risk of revision was independent of age, gender, American Society of Anesthesiologists grade, body mass index, surgeon volume, surgical approach, brand of cement/presence of antibiotic, femoral head material (stainless steel/alumina) and stem taper size/offset. However, the risk of revision for dislocation was significantly higher with a ‘plus’ offset head (HR 2.05, p = 0.003) and a hooded acetabular component (HR 2.34, p < 0.001). In summary, we found that there were significant differences in failure between different designs of acetabular component and sizes of femoral head after adjustment for a range of covariates.


  • Patient and implant survival following 4323 total hip replacements for acute femoral neck fracture

    by S. S. Jameson, J. Kyle, P. N. Baker, J. Mason, D. J. Deehan, I. A. McMurtry, M. R. Reed

    United Kingdom National Institute for Health and Clinical Excellence guidelines recommend the use of total hip replacement (THR) for displaced intracapsular fractures of the femoral neck in cognitively intact patients, who were independently mobile prior to the injury. This study aimed to analyse the risk factors associated with revision of the implant and mortality following THR, and to quantify risk. National Joint Registry data recording a THR performed for acute fracture of the femoral neck between 2003 and 2010 were analysed. Cox proportional hazards models were used to investigate the extent to which risk of revision was related to specific covariates. Multivariable logistic regression was used to analyse factors affecting peri-operative mortality (< 90 days). A total of 4323 procedures were studied. There were 80 patients who had undergone revision surgery at the time of censoring (five-year revision rate 3.25%, 95% confidence interval 2.44 to 4.07) and 137 patients (3.2%) patients died within 90 days. After adjusting for patient and surgeon characteristics, an increased risk of revision was associated with the use of cementless prostheses compared with cemented (hazard ratio (HR) 1.33, p = 0.021). Revision was independent of bearing surface and head size. The risk of mortality within 90 days was significantly increased with higher American Society of Anesthesiologists (ASA) grade (grade 3: odds ratio (OR) 4.04, p < 0.001; grade 4/5: OR 20.26, p < 0.001; both compared with grades 1/2) and older age (≥ 75 years: OR 1.65, p = 0.025), but reduced over the study period (9% relative risk reduction per year). THR is a good option in patients aged < 75 years and with ASA 1/2. Cementation of the femoral component does not adversely affect peri-operative mortality but improves survival of the implant in the mid-term when compared with cementless femoral components. There are no benefits of using head sizes > 28 mm or bearings other than metal-on-polyethylene. More research is required to determine the benefits of THR over hemiarthroplasty in older patients and those with ASA grades > 2.