Corneal Thickness After SMILE Affects Scheimpflug-based Dynamic Tonometry
Authors:
- Joaquín FernándezJFJoaquín Fernández
- Manuel Rodríguez-VallejoMRManuel Rodríguez-Vallejo
- Javier MartínezJMJavier Martínez
- Ana TausteATAna Tauste
- David P. PiñeroDPDavid P. Piñero
- 1 December 2016
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 32 (12) , 821-828
Abstract
PURPOSE: To evaluate the corneal biomechanical changes due to small incision lenticule extraction (SMILE) measured by Scheimpflug-based dynamic tonometry and to assess the impact of the corneal thickness.METHODS: Sixty-eight patients measured with the Corvis ST (Oculus Optikgeräte GmbH, Wetzlar, Germany) preoperatively and 1 month after SMILE were included in this retrospective observational study. Patients were divided into three groups depending on the preoperative spherical equivalent: low from −1.00 to −3.00 diopters (D), medium from −3.25 to −5.00 D, and high from −5.25 to −7.25 D. Changes in Corvis ST parameters due to the surgery were analyzed and new indexes for correcting the impact of corneal thickness were proposed.RESULTS: First and second applanation times changed after SMILE (P< .0001) but no differences were found in the comparison between these relative changes (P= .31). First applanation time was correlated with central corneal thickness (r= 0.368,P= .002) but not second applanation time (r= −0.149,P= .23). The change in first applanation time due to SMILE was different among myopic groups (P= .007) but equal when a new index that considers the removed central corneal thickness was used for comparison (P= .31). Deformation amplitude was also increased after SMILE (P< .0001), but after subtracting the removed corneal thickness from the postoperative deformation amplitude the result was equal to the preoperative deformation amplitude (P= .26).CONCLUSIONS: SMILE produces significant changes in the Corvis ST parameters of time and deformation amplitude, but these changes are mainly explained by the confounding variable of corneal thickness.[J Refract Surg.2016;32(12):821–828.]Keywords
This publication has 33 references indexed in Scilit:
- Comparison of Corneal Biomechanical Characteristics After Surface Ablation Refractive Surgery and Novel Lamellar Refractive SurgeryCornea, 2015
- Contralateral Eye Comparison Between Femtosecond Small Incision Intrastromal Lenticule Extraction at Depths of 100 and 160 μmCornea, 2015
- Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometerClinical Ophthalmology, 2015
- Examination of ocular biomechanics with a new Scheimpflug technology after corneal refractive surgeryContact Lens and Anterior Eye, 2014
- Comparison of Corneal Deformation Parameters After SMILE, LASEK, and Femtosecond Laser-Assisted LASIKJournal of Refractive Surgery, 2014
- Comparison of corneal hysteresis and corneal resistance factor after small incision lenticule extraction and femtosecond laser-assisted LASIK: A prospective fellow eye studyContact Lens and Anterior Eye, 2014
- Mathematical Model to Compare the Relative Tensile Strength of the Cornea After PRK, LASIK, and Small Incision Lenticule ExtractionJournal of Refractive Surgery, 2013
- Effects of Altered Corneal Stiffness on Native and Postoperative LASIK Corneal Biomechanical Behavior: A Whole-eye Finite Element AnalysisJournal of Refractive Surgery, 2009
- Depth-dependent Cohesive Tensile Strength in Human Donor Corneas: Implications for Refractive SurgeryJournal of Refractive Surgery, 2008
- Corneal Ectasia After Laser In Situ Keratomileusis in Patients Without Apparent Preoperative Risk FactorsCornea, 2006