Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer
Authors:
Open Access
- 1 February 2015
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. 9, 305-311
Abstract
Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer Andreas Frings,1,* Stephan J Linke,1,2,* Eva L Bauer,1 Vasyl Druchkiv,1 Toam Katz,1,2 Johannes Steinberg1,2 1Department of Ophthalmology, University Medical Center Hamburg-Eppendorf (UKE), Hamburg, Germany; 2Care Vision Refractive Center, Hamburg, Germany *These authors contributed equally to this work Purpose: This study was initiated to evaluate biomechanical changes using the Corvis ST tonometer (CST) on the cornea after laser in situ keratomileusis (LASIK). Setting: University Medical Center Hamburg-Eppendorf, Germany, and Care Vision Refractive Centers, Germany. Design: Retrospective cohort study. Methods: This retrospective study included 37 eyes of 37 refractive patients. All CST measurements were performed 1 day before surgery and at the 1-month follow-up examination. The LASIK procedure included mechanical flap preparation using a Moria SBKmicrokeratome and an Allegretto excimer laser platform. Results: Statistically significant differences were observed for mean first applanation length, mean first and second deflection lengths, mean first and second deflection amplitudes, radius of curvature, and peak distance. Significant positive correlations were found between the change (∆) of radius of curvature and manifest refraction spherical equivalent (MRSE), ablation depth, and ∆intraocular pressure as well as between AD and ∆HC-time. Each diopter of myopic correction in MRSE resulted in an increase in ∆radius of curvature of 0.2 mm. Conclusion: Several CST parameters were statistically significantly altered by LASIK, thereby indicating that flap creation, ablation, or both, significantly change the ability of the cornea to absorb or dissipate energy. Keywords: LASIK, corneal biomechanics, refractive surgery, Corvis STKeywords
This publication has 25 references indexed in Scilit:
- Ocular residual astigmatism: Effects of demographic and ocular parameters in myopic laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2014
- Effects of age on corneal deformation by non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug cameraArquivos Brasileiros de Oftalmologia, 2013
- Repeatability of Ocular Biomechanical Data Measurements With a Scheimpflug-Based Noncontact Device on Normal CorneasJournal of Refractive Surgery, 2013
- Repeatability and Reproducibility of Goldmann Applanation, Dynamic Contour, and Ocular Response Analyzer TonometryJournal of Glaucoma, 2013
- Corneal biomechanical properties and intraocular pressure measurement in patients with nanophthalmosBritish Journal of Ophthalmology, 2012
- What Biomechanical Properties of the Cornea Are Relevant for the Clinician?Survey of Ophthalmology, 2007
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005
- Corneal Topographic and Pachymetric Screening of Keratorefractive PatientsJournal of Refractive Surgery, 2003
- Biomechanics of the Cornea and Wavefront-guided Laser Refractive SurgeryJournal of Refractive Surgery, 2002
- On the biomechanical properties of the cornea with particular reference to refractive surgery.1998