Finite element simulation of treatment with locking plate for distal fibula fractures
Authors:
- 15 July 2024
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (4) , 1461-1468
Abstract
An improved Finite Element Model(FEM) is applied to compare the biomechanical stability of plates with three different options in the treatment of distal fibula fractures in this study. The Computed Tomography(CT) scan of the knee to ankle segment of a volunteer was performed. A 3D fibula FEM was reconstructed based on the CT data. Three different loads (uni-pedal standing, torsion, and twisting) were applied, the same as in the experiments in the literature. The stresses and strains of the three options were compared under the same loads, using a 4-hole locking plate (Option A), a 5-hole locking plate (Option B), and a 6-hole locking plate (Option C) in a standard plate for lateral internal fixation. The simulation results show that all three options showed a stress masking effect. Option C had the best overall biomechanical performance and could effectively distribute the transferred weight. This is because option C has greater torsional stiffness and better biomechanical stability than options A and B, and therefore, option C is the recommended internal fixation method for distal fibula fractures. The Finite Element Analysis(FEA) method developed in this work applies to the stress analysis of fracture treatment options in other body parts.Keywords
All Related Versions
Funding Information
- Tianjin Applied Basic Research Multiple Investment Fund (21JCYBJC01400)
This publication has 11 references indexed in Scilit:
- Fibular Lengthening Osteotomy With Revision Syndesmotic Repair for Ankle Fracture MalunionJournal of Orthopaedic Trauma, 2019
- Inferomedial cortical bone contact and fixation with calcar screws on the dynamic and static mechanical stability of proximal humerus fracturesJournal of Orthopaedic Surgery and Research, 2019
- Distal fibula fracture fixation: Biomechanical evaluation of three different fixation implantsFoot and Ankle Surgery, 2016
- Fixation of Distal Fibula FracturesFoot & Ankle International, 2014
- Risk Factors for Failure of Locked Plate Fixation of Distal Femur FracturesJournal of Orthopaedic Trauma, 2014
- A large scale finite element study of a cementless osseointegrated tibial trayJournal of Biomechanics, 2013
- Minimally Invasive Plate Osteosynthesis of the Distal Fibula With the Locking Compression Plate: First Experience of 20 CasesJournal of Orthopaedic Trauma, 2011
- Peroneal Tendon Lesions Caused by Antiglide Plates Used for Fixation of Lateral Malleolar Fractures: The Effect of Plate and Screw PositionFoot & Ankle International, 2005
- Biomechanical testing of the LCP – how can stability in locked internal fixators be controlled?Injury, 2003
- The Evolution of Femoral Shaft Plating TechniqueClinical Orthopaedics and Related Research, 1998